Inez Rn Nichols
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Inez Rn Nichols has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
James P. Rn Humphrey
IV Therapy Coordinator, South Georgia Medical Center, Valdosta (Ms Nichols); and Associate Professor of Nursing and Coordinator of Advanced Courses for Adults at Valdosta State University College of Nursing, Valdosta, Georgia (Dr Humphrey)
1 shared publication
Latest Publications
- 1 May 2008
- Published by Wolters Kluwer Health in Journal of Infusion Nursing
- Vol. 31 (3) , 165-176
The Efficacy of Upper Arm Placement of Peripherally Inserted Central Catheters Using Bedside Ultrasound and Microintroducer Technique
In one hospital in southern Georgia, the review and analysis of 500 peripherally inserted central catheter procedural attempts by designated, specialty nurses using microintroducer technique and ultrasound guidance revealed an overall catheter placement success rate of 94.6%. This research analysis also provided information on the disposition of those 6-French dual-lumen and triple-lumen, power-injectable peripherally inserted central catheters actually placed in situ on subjects who remained hospitalized or within the hospital's rehabilitation facility. Of the 422 catheters removed, none exhibited signs or symptoms of mechanical phlebitis, and one tested positive per laboratory analysis for organisms confirming infection.
- 1 May 2008
- Published by Wolters Kluwer Health in Journal of Infusion Nursing
- Vol. 31 (3) , 165-176
The Efficacy of Upper Arm Placement of Peripherally Inserted Central Catheters Using Bedside Ultrasound and Microintroducer Technique
In one hospital in southern Georgia, the review and analysis of 500 peripherally inserted central catheter procedural attempts by designated, specialty nurses using microintroducer technique and ultrasound guidance revealed an overall catheter placement success rate of 94.6%. This research analysis also provided information on the disposition of those 6-French dual-lumen and triple-lumen, power-injectable peripherally inserted central catheters actually placed in situ on subjects who remained hospitalized or within the hospital's rehabilitation facility. Of the 422 catheters removed, none exhibited signs or symptoms of mechanical phlebitis, and one tested positive per laboratory analysis for organisms confirming infection.