Dead-Time Compensation for Grid-Tied Voltage Source Inverters With SVM$^{2}$ PC
Authors:
- Dimas Alã SchuetzDSDimas Alã Schuetz
- Caio Ruviaro Dantas OsórioCOCaio Ruviaro Dantas Osório
- Luiz Antonio MaccariLMLuiz Antonio Maccari
- Daniel Martins LimaDLDaniel Martins Lima
- Fernanda de Morais CarnieluttiFernanda de Morais Carnielutti
- Vinícius Foletto MontagnerVMVinícius Foletto Montagner
- Humberto PinheiroHPHumberto Pinheiro
- 3 April 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 6366-6379
Abstract
This paper presents a dead-time compensation strategy for grid-tied inverters with large output current ripple. A current prediction over the switching sequence is proposed to obtain the current polarity at each switching transition. As a result, the effect of the dead time on the inverter output voltages can be determined and the duty cycles are compensated to maintain the original switching transitions instants. In addition, a disturbance observer is used to mitigate the current prediction error, caused by the nonidealities of the grid-tied inverter system. The constraints obtained from the dead-time compensation method are included in the optimization problem of the model predictive control algorithm to ensure operation in the feasible region of the space-vector diagram. Hardware-in-the-loop and experimental results are obtained to compare the proposed method with a classical compensation strategy without current prediction over the switching period, as well as to demonstrate the good performance and effectiveness of the proposed strategy.Keywords
Funding Information
- National Council for Scientific and Technological Development (407654/2021-6, 313796/2021-1, 303992/2022-0)
This publication has 38 references indexed in Scilit:
- A Novel Method to Reduce Low-Frequency Output Current Ripple of PWM InvertersIEEE Transactions on Industry Applications, 2022
- Modulated Model Predictive Control Applied to LCL-Filtered Grid-Tied Inverters: A Convex Optimization ApproachIEEE Open Journal of Industry Applications, 2021
- A Compensation Method of Dead-Time and Forward Voltage Drop for Inverter Operating at Low FrequencyJournal of Electrical Engineering & Technology, 2019
- Vector based dead-time compensation for three-level T-type convertersIEEE Transactions on Industry Applications, 2015
- A Simple and Direct Dead-Time Effect Compensation Scheme in PWM-VSIIEEE Transactions on Industry Applications, 2014
- Current-Ripple Prediction for Three-Phase PWM ConvertersIEEE Transactions on Industry Applications, 2013
- Dead Time Compensation Method for Voltage-Fed PWM InverterIEEE Transactions on Energy Conversion, 2009
- Dead-Time Elimination of PWM-Controlled Inverter/Converter Without Separate Power Sources for Current Polarity Detection CircuitIEEE Transactions on Industrial Electronics, 2009
- Model Predictive Control—A Simple and Powerful Method to Control Power ConvertersIEEE Transactions on Industrial Electronics, 2008
- Interfacing Renewable Energy Sources to the Utility Grid Using a Three-Level InverterIEEE Transactions on Industrial Electronics, 2006