Luiz Antonio Maccari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Luiz Antonio Maccari has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Vinicius Foletto Montagner
Federal University of Santa Maria, Santa Maria, Brazil
4 shared publications - Ricardo Coração de Leão Fontoura de Oliveira
Faculdade de Engenharia Eltrica e de Computao, Universidade Estadual de Campinas (UNICAMP), Campinas, Brazil
3 shared publications - Caio Ruviaro Dantas Osorio
Typhoon HIL, Novi Sad, Serbia
2 shared publications - Daniel Martins Lima
Federal University of Santa Catarina, Blumenau, Brazil
2 shared publications - Dimas Alã Schuetz
Federal University of Santa Maria, Santa Maria, Brazil
2 shared publications - Fernanda de Morais Carnielutti
Federal University of Santa Maria, Santa Maria, Brazil
2 shared publications
Latest Publications
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 6366-6379
Dead-Time Compensation for Grid-Tied Voltage Source Inverters With SVM$^{2}$ PC
This paper presents a dead-time compensation strategy for grid-tied inverters with large output current ripple. A current prediction over the switching sequence is proposed to obtain the current polarity at each switching transition. As a result, the effect of the dead time on the inverter output voltages can be determined and the duty cycles are compensated to maintain the original switching transitions instants. In addition, a disturbance observer is used to mitigate the current prediction error, caused by the nonidealities of the grid-tied inverter system. The constraints obtained from the dead-time compensation method are included in the optimization problem of the model predictive control algorithm to ensure operation in the feasible region of the space-vector diagram. Hardware-in-the-loop and experimental results are obtained to compare the proposed method with a classical compensation strategy without current prediction over the switching period, as well as to demonstrate the good performance and effectiveness of the proposed strategy.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 6366-6379
Dead-Time Compensation for Grid-Tied Voltage Source Inverters With SVM$^{2}$ PC
This paper presents a dead-time compensation strategy for grid-tied inverters with large output current ripple. A current prediction over the switching sequence is proposed to obtain the current polarity at each switching transition. As a result, the effect of the dead time on the inverter output voltages can be determined and the duty cycles are compensated to maintain the original switching transitions instants. In addition, a disturbance observer is used to mitigate the current prediction error, caused by the nonidealities of the grid-tied inverter system. The constraints obtained from the dead-time compensation method are included in the optimization problem of the model predictive control algorithm to ensure operation in the feasible region of the space-vector diagram. Hardware-in-the-loop and experimental results are obtained to compare the proposed method with a classical compensation strategy without current prediction over the switching period, as well as to demonstrate the good performance and effectiveness of the proposed strategy.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 19 (1) , 414-425
Space Vector Modulated Model Predictive Control for Grid-Tied Converters
This article proposes a space vector modulated model predictive control (SVM $^{2}$ PC) for voltage source converters. It overcomes limitations of standard finite control set model predictive controller, ensuring fast dynamic response, fixed switching frequency, and low computational burden. It combines control and modulation in a convex optimization problem with affine inequality constraints to minimize the tracking errors of the output variables. First, the sector of the space vector diagram where the unconstrained solution lies is identified. Then, using the Karush–Kuhn–Tucker conditions, feasible duty cycles are computed for both linear and overmodulation regions. The proposed SVM $^{2}$ PC is extended to multilevel converters. Hardware in the loop results are presented for three different case studies: 1) Grid-forming inverter with LC filter; 2) two-level grid-following inverter with LCL filter; and 3) grid-following neutral point clamped inverter with LCL filter. Experimental results demonstrate that the proposed SVM $^{2}$ PC provides good performance, fast response, and low computational burden when compared with previously reported alternatives.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 19 (1) , 414-425
Space Vector Modulated Model Predictive Control for Grid-Tied Converters
This article proposes a space vector modulated model predictive control (SVM $^{2}$ PC) for voltage source converters. It overcomes limitations of standard finite control set model predictive controller, ensuring fast dynamic response, fixed switching frequency, and low computational burden. It combines control and modulation in a convex optimization problem with affine inequality constraints to minimize the tracking errors of the output variables. First, the sector of the space vector diagram where the unconstrained solution lies is identified. Then, using the Karush–Kuhn–Tucker conditions, feasible duty cycles are computed for both linear and overmodulation regions. The proposed SVM $^{2}$ PC is extended to multilevel converters. Hardware in the loop results are presented for three different case studies: 1) Grid-forming inverter with LC filter; 2) two-level grid-following inverter with LCL filter; and 3) grid-following neutral point clamped inverter with LCL filter. Experimental results demonstrate that the proposed SVM $^{2}$ PC provides good performance, fast response, and low computational burden when compared with previously reported alternatives.
- 17 January 2017
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 28 (2) , 159-170
Robust Stability Analysis of Grid-Connected Converters Based on Parameter-Dependent Lyapunov Functions
- 17 January 2017
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 28 (2) , 159-170
Robust Stability Analysis of Grid-Connected Converters Based on Parameter-Dependent Lyapunov Functions
- Open Access
- 1 August 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (8) , 1490-1499
Robust optimal current control for grid‐connected three‐phase pulse‐width modulated converters
This study deals with the current control of three‐phase inverters connected to the grid by means of LCL filters. The control action is given by the feedback of the filter states, in coordinates αβ 0, and of the internal states of resonant controllers. The control gains are computed by means of an optimal linear quadratic regulator that is robust to uncertain and time‐varying parameters related to the grid impedance at the point of common coupling. As contributions, one has the detailed proof of a robust discrete linear quadratic control, showing its applicability also for the time‐varying case, the experimental validation of the results in terms of the total harmonic distortion and harmonic limits for the grid injected current, according to the IEEE 1547 standard, and the analysis of the ℋ ∞ norm of the closed‐loop system for several values of grid inductance, indicating a value of grid inductance for which one has best performance for the time‐invariant case. For comparison, a conventional state feedback controller is designed and implemented, showing the limitation of the non‐robust strategy.
- 1 August 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (8) , 1490-1499
Open AccessRobust optimal current control for grid‐connected three‐phase pulse‐width modulated converters
This study deals with the current control of three‐phase inverters connected to the grid by means of LCL filters. The control action is given by the feedback of the filter states, in coordinates αβ 0, and of the internal states of resonant controllers. The control gains are computed by means of an optimal linear quadratic regulator that is robust to uncertain and time‐varying parameters related to the grid impedance at the point of common coupling. As contributions, one has the detailed proof of a robust discrete linear quadratic control, showing its applicability also for the time‐varying case, the experimental validation of the results in terms of the total harmonic distortion and harmonic limits for the grid injected current, according to the IEEE 1547 standard, and the analysis of the ℋ ∞ norm of the closed‐loop system for several values of grid inductance, indicating a value of grid inductance for which one has best performance for the time‐invariant case. For comparison, a conventional state feedback controller is designed and implemented, showing the limitation of the non‐robust strategy.
- Open Access
- 1 September 2014
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 7 (9) , 2233-2241
Design and implementation of a discrete‐time H ‐infinity controller for uninterruptible power supply systems
This study provides a digital ℋ ∞ controller design suitable for uninterruptible power supply inverters, yielding results that comply with the IEC 62040‐3 Standard. An augmented state space model for the system is given, taking into account the delay from the digital implementation of the control signal, and resonant controllers that ensure asymptotic tracking of the reference and good rejection of load disturbances. It is shown a case where an ℋ ∞ optimal state feedback controller cannot provide good results because of the high control gains. To solve this problem, an ℋ ∞ suboptimal controller is proposed, taking into account a prescribed bound for the ℋ ∞ norm of the closed‐loop system and a parameter for limitation of the norm of the control gain vector. This suboptimal controller provides gains that lead to suitable results, complying with the constraints from the IEC 62040‐3 Standard. These results are compared with those from a widely used state feedback controller, providing superior performance, even with a much simpler design procedure. Simulation and experimental results have a good correspondence. Finally, the study illustrates that the ℋ ∞ norm of the closed‐loop system can be seen as the output impedance over the frequency. From this information, using the small gain theorem, one can get the admittance value of the linear loads that preserve stability when connected to the uninterruptible power supply.
- 1 September 2014
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 7 (9) , 2233-2241
Open AccessDesign and implementation of a discrete‐time H ‐infinity controller for uninterruptible power supply systems
This study provides a digital ℋ ∞ controller design suitable for uninterruptible power supply inverters, yielding results that comply with the IEC 62040‐3 Standard. An augmented state space model for the system is given, taking into account the delay from the digital implementation of the control signal, and resonant controllers that ensure asymptotic tracking of the reference and good rejection of load disturbances. It is shown a case where an ℋ ∞ optimal state feedback controller cannot provide good results because of the high control gains. To solve this problem, an ℋ ∞ suboptimal controller is proposed, taking into account a prescribed bound for the ℋ ∞ norm of the closed‐loop system and a parameter for limitation of the norm of the control gain vector. This suboptimal controller provides gains that lead to suitable results, complying with the constraints from the IEC 62040‐3 Standard. These results are compared with those from a widely used state feedback controller, providing superior performance, even with a much simpler design procedure. Simulation and experimental results have a good correspondence. Finally, the study illustrates that the ℋ ∞ norm of the closed‐loop system can be seen as the output impedance over the frequency. From this information, using the small gain theorem, one can get the admittance value of the linear loads that preserve stability when connected to the uninterruptible power supply.