Numerical Simulation and Experimental Validation of Calibrant-Loaded Extraction Phase Standardization Approach
Open Access
- 24 August 2016
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (17) , 8632-8639
Abstract
We present the kinetics of calibrant release and analyte uptake between the sample and calibrant-loaded extraction phase, CL-EP, with a finite-element analysis (FEA) using COMSOL Multiphysics software package. Effect of finite and infinite sample volume conditions, as well as various sample environment parameters such as fluid flow velocity, temperature, and presence of a binding matrix component were investigated in detail with the model in relation to the performance of the calibration. The simulation results supported by experimental data demonstrate the suitability of the CL-EP method for analysis of samples with variation of the sample environment parameters. The calibrant-loaded approach can provide both total and free concentrations from a single experiment based on whether the partition coefficient (Kes) value being used is measured in a matrix-matched sample or in a matrix-free sample, respectively. Total concentrations can also be obtained by utilizing CL-EP in combination with external matrix-matched calibrations, which can be employed to automate the sampling process and provide corrections for variations in sample preparation, matrix effects, and detection processes. This approach is also suitable for very small volumes of sample, where addition of an internal standard in the sample is either troublesome or can change the sample characteristics.Keywords
Funding Information
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada
- Ontario Research Fund
This publication has 25 references indexed in Scilit:
- Numerical Modeling of Solid-Phase Microextraction: Binding Matrix Effect on Equilibrium TimeAnalytical Chemistry, 2015
- Passive samplers of hydrophobic organic chemicals reach equilibrium faster in the laboratory than in the fieldMarine Pollution Bulletin, 2015
- Calibration of pre-equilibrium HF-LPME and its application to the rapid determination of free analytes in biological fluidsJournal of Chromatography B, 2015
- Solid-phase Microextraction (SPME) with Stable Isotope Calibration for Measuring Bioavailability of Hydrophobic Organic ContaminantsEnvironmental Science & Technology, 2013
- Modeling of diffusion controlled drug deliveryJournal of Controlled Release, 2012
- Pre-Equilibrium Solid-Phase Microextraction of Free Analyte in Complex Samples: Correction for Mass Transfer Variation from Protein Binding and Matrix TortuosityAnalytical Chemistry, 2011
- A critical review in calibration methods for solid-phase microextractionAnalytica Chimica Acta, 2008
- Poly(dimethylsiloxane) as Passive Sampler Material for Hydrophobic Chemicals: Effect of Chemical Properties and Sampler Characteristics on Partitioning and Equilibration TimesAnalytical Chemistry, 2008
- On-Fiber Standardization Technique for Solid-Coated Solid-Phase MicroextractionAnalytical Chemistry, 2006
- Kinetics and the On-Site Application of Standards in A Solid-Phase Microextration FiberAnalytical Chemistry, 2004