Nazmul Alam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nazmul Alam has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Janusz Pawliszyn
University of Waterloo
8 shared publications Rezwan Miah
Shahjalal University of Science and Technology
3 shared publications- Shaheen M. Sarkar
Technological University of the Shannon Midlands Midwest, Moylish Limerick, V94, EC5T Ireland
3 shared publications - Emanuela Gionfriddo
Department of Chemistry and Biochemistry, University of Toledo, Toledo, OH, 43606, USA; Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, NY, 14260-3000, USA
2 shared publications - Nathaly Reyes-Garcés
AstraZeneca (United States)
2 shared publications - Varoon Singh
Department of Chemistry, University of Waterloo, 200 University Avenue west, Waterloo, Ontario, N2L 3G1, Canada
2 shared publications
Latest Publications
- 27 August 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (19) , 11548-11555
Effect of Transport Parameters and Device Geometry on Extraction Kinetics and Efficiency in Direct Immersion Solid-phase Microextraction
- 27 August 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (19) , 11548-11555
Effect of Transport Parameters and Device Geometry on Extraction Kinetics and Efficiency in Direct Immersion Solid-phase Microextraction
- 5 February 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (4) , 2430-2433
Effect of Binding Components in Complex Sample Matrices on Recovery in Direct Immersion Solid-Phase Microextraction: Friends or Foe?
The development of matrix compatible coatings for solid-phase microextraction (SPME) has enabled direct extraction of analytes from complex sample matrices. The direct immersion (DI) mode of SPME when utilized in conjunction with such extraction phases facilitates extraction of a wide range of analytes from complex matrices without the incurrence of fouling or coating saturation. In this work, mathematical models and computational simulations were employed to investigate the effect of binding components present in complex samples on the recovery of small molecules varying in logP for extractions carried out using the direct immersion approach. The presented findings corroborate that the studied approach indeed enables the extraction of both polar and nonpolar analytes from complex matrices, provided a suitable sorbent is employed. Further results indicated that, in certain cases, the kinetics of extraction of a given analyte in its free form might be dependent on the desorption kinetics of their bound form from matrix components, which might lower total recoveries of analytes with high affinity for the matrix. However, the binding of analytes to matrix components also enables SPME to extract a balanced quantity of different logP analytes, facilitated by multiphase equilibria, with a single extraction device.
- 5 February 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (4) , 2430-2433
Effect of Binding Components in Complex Sample Matrices on Recovery in Direct Immersion Solid-Phase Microextraction: Friends or Foe?
The development of matrix compatible coatings for solid-phase microextraction (SPME) has enabled direct extraction of analytes from complex sample matrices. The direct immersion (DI) mode of SPME when utilized in conjunction with such extraction phases facilitates extraction of a wide range of analytes from complex matrices without the incurrence of fouling or coating saturation. In this work, mathematical models and computational simulations were employed to investigate the effect of binding components present in complex samples on the recovery of small molecules varying in logP for extractions carried out using the direct immersion approach. The presented findings corroborate that the studied approach indeed enables the extraction of both polar and nonpolar analytes from complex matrices, provided a suitable sorbent is employed. Further results indicated that, in certain cases, the kinetics of extraction of a given analyte in its free form might be dependent on the desorption kinetics of their bound form from matrix components, which might lower total recoveries of analytes with high affinity for the matrix. However, the binding of analytes to matrix components also enables SPME to extract a balanced quantity of different logP analytes, facilitated by multiphase equilibria, with a single extraction device.
- Open Access
- 1 February 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1001, 40-50
The effect of hematocrit on solid-phase microextraction
- 1 February 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1001, 40-50
Open AccessThe effect of hematocrit on solid-phase microextraction
- Top Cited PapersOpen Access
- 8 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (1) , 302-360
Advances in Solid Phase Microextraction and Perspective on Future Directions
- 8 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (1) , 302-360
Top Cited PapersOpen AccessAdvances in Solid Phase Microextraction and Perspective on Future Directions
- 24 March 2017
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 56 (13) , 3679-3686
Calibrant Free Sampling and Enrichment with Solid-Phase Microextraction: Computational Simulation and Experimental Verification
- 24 March 2017
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 56 (13) , 3679-3686
Calibrant Free Sampling and Enrichment with Solid-Phase Microextraction: Computational Simulation and Experimental Verification
- 14 February 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (5) , 2978-2985
Insights into the Effect of the PDMS-Layer on the Kinetics and Thermodynamics of Analyte Sorption onto the Matrix-Compatible Solid Phase Microextraction Coating
The currently presented research investigated the performance of matrix compatible PDMS-overcoated fibers (PDMS-DVB/PDMS) as compared to unmodified PDMS/DVB coatings using aqueous samples and employing a wide range of analyte polarities, molecular weights, and functionalities. In the first part of the work, a kinetic approach was taken to investigate the effect of the PDMS outer layer on the uptake rate of analytes during the mass transfer process. In short, the results can be simplified into two models: (1) the rate-limiting step is the diffusion through the coating and (2) the rate-limiting step is the diffusion through the aqueous diffusional boundary layer. For polar compounds, according to the theoretical discussion, the rate-limiting step is the diffusion through the coating; therefore, the outer PDMS layer influences the uptake rate into the matrix compatible coatings. On the other hand, for nonpolar compounds, the rate-limiting step of the uptake process is diffusion through the aqueous diffusional boundary layer; as such, the overcoated PDMS does not affect uptake rate into the matrix-compatible coatings as compared to DVB/PDMS fibers. From a thermodynamic point of view, the calculated fiber constants further corroborate the hypothesis that the additional PDMS layer does not impair the extraction phase capacity.
- 14 February 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (5) , 2978-2985
Insights into the Effect of the PDMS-Layer on the Kinetics and Thermodynamics of Analyte Sorption onto the Matrix-Compatible Solid Phase Microextraction Coating
The currently presented research investigated the performance of matrix compatible PDMS-overcoated fibers (PDMS-DVB/PDMS) as compared to unmodified PDMS/DVB coatings using aqueous samples and employing a wide range of analyte polarities, molecular weights, and functionalities. In the first part of the work, a kinetic approach was taken to investigate the effect of the PDMS outer layer on the uptake rate of analytes during the mass transfer process. In short, the results can be simplified into two models: (1) the rate-limiting step is the diffusion through the coating and (2) the rate-limiting step is the diffusion through the aqueous diffusional boundary layer. For polar compounds, according to the theoretical discussion, the rate-limiting step is the diffusion through the coating; therefore, the outer PDMS layer influences the uptake rate into the matrix compatible coatings. On the other hand, for nonpolar compounds, the rate-limiting step of the uptake process is diffusion through the aqueous diffusional boundary layer; as such, the overcoated PDMS does not affect uptake rate into the matrix-compatible coatings as compared to DVB/PDMS fibers. From a thermodynamic point of view, the calculated fiber constants further corroborate the hypothesis that the additional PDMS layer does not impair the extraction phase capacity.
- Open Access
- 24 August 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (17) , 8632-8639
Numerical Simulation and Experimental Validation of Calibrant-Loaded Extraction Phase Standardization Approach
We present the kinetics of calibrant release and analyte uptake between the sample and calibrant-loaded extraction phase, CL-EP, with a finite-element analysis (FEA) using COMSOL Multiphysics software package. Effect of finite and infinite sample volume conditions, as well as various sample environment parameters such as fluid flow velocity, temperature, and presence of a binding matrix component were investigated in detail with the model in relation to the performance of the calibration. The simulation results supported by experimental data demonstrate the suitability of the CL-EP method for analysis of samples with variation of the sample environment parameters. The calibrant-loaded approach can provide both total and free concentrations from a single experiment based on whether the partition coefficient (Kes) value being used is measured in a matrix-matched sample or in a matrix-free sample, respectively. Total concentrations can also be obtained by utilizing CL-EP in combination with external matrix-matched calibrations, which can be employed to automate the sampling process and provide corrections for variations in sample preparation, matrix effects, and detection processes. This approach is also suitable for very small volumes of sample, where addition of an internal standard in the sample is either troublesome or can change the sample characteristics.
- 24 August 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (17) , 8632-8639
Open AccessNumerical Simulation and Experimental Validation of Calibrant-Loaded Extraction Phase Standardization Approach
We present the kinetics of calibrant release and analyte uptake between the sample and calibrant-loaded extraction phase, CL-EP, with a finite-element analysis (FEA) using COMSOL Multiphysics software package. Effect of finite and infinite sample volume conditions, as well as various sample environment parameters such as fluid flow velocity, temperature, and presence of a binding matrix component were investigated in detail with the model in relation to the performance of the calibration. The simulation results supported by experimental data demonstrate the suitability of the CL-EP method for analysis of samples with variation of the sample environment parameters. The calibrant-loaded approach can provide both total and free concentrations from a single experiment based on whether the partition coefficient (Kes) value being used is measured in a matrix-matched sample or in a matrix-free sample, respectively. Total concentrations can also be obtained by utilizing CL-EP in combination with external matrix-matched calibrations, which can be employed to automate the sampling process and provide corrections for variations in sample preparation, matrix effects, and detection processes. This approach is also suitable for very small volumes of sample, where addition of an internal standard in the sample is either troublesome or can change the sample characteristics.
- 7 September 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (19) , 9846-9854
Numerical Modeling of Solid-Phase Microextraction: Binding Matrix Effect on Equilibrium Time
Solid-phase microextraction (SPME) is a well-known sampling and sample preparation technique used for a wide variety of analytical applications. As there are various complex processes taking place at the time of extraction that influence the parameters of optimum extraction, a mathematical model and computational simulation describing the SPME process is required for experimentalists to understand and implement the technique without performing multiple costly and time-consuming experiments in the laboratory. In this study, a mechanistic mathematical model for the processes occurring in SPME extraction of analyte(s) from an aqueous sample medium is presented. The proposed mechanistic model was validated with previously reported experimental data from three different sources. Several key factors that affect the extraction kinetics, such as sample agitation, fiber coating thickness, and presence of a binding matrix component, are discussed. More interestingly, for the first time, shorter or longer equilibrium times in the presence of a binding matrix component were explained with the help of an asymptotic analysis. Parameters that contribute to the variation of the equilibrium times are discussed, with the assumption that one binding matrix component is present in a static sample. Numerical simulation results show that the proposed model captures the phenomena occurring in SPME, leading to a clearer understanding of this process. Therefore, the currently presented model can be used to identify optimum experimental parameters without the need to perform a large number of experiments in the laboratory.
- 7 September 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (19) , 9846-9854
Numerical Modeling of Solid-Phase Microextraction: Binding Matrix Effect on Equilibrium Time
Solid-phase microextraction (SPME) is a well-known sampling and sample preparation technique used for a wide variety of analytical applications. As there are various complex processes taking place at the time of extraction that influence the parameters of optimum extraction, a mathematical model and computational simulation describing the SPME process is required for experimentalists to understand and implement the technique without performing multiple costly and time-consuming experiments in the laboratory. In this study, a mechanistic mathematical model for the processes occurring in SPME extraction of analyte(s) from an aqueous sample medium is presented. The proposed mechanistic model was validated with previously reported experimental data from three different sources. Several key factors that affect the extraction kinetics, such as sample agitation, fiber coating thickness, and presence of a binding matrix component, are discussed. More interestingly, for the first time, shorter or longer equilibrium times in the presence of a binding matrix component were explained with the help of an asymptotic analysis. Parameters that contribute to the variation of the equilibrium times are discussed, with the assumption that one binding matrix component is present in a static sample. Numerical simulation results show that the proposed model captures the phenomena occurring in SPME, leading to a clearer understanding of this process. Therefore, the currently presented model can be used to identify optimum experimental parameters without the need to perform a large number of experiments in the laboratory.
- 1 October 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 845, 45-52
Aptamer-functionalized solid phase microextraction–liquid chromatography/tandem mass spectrometry for selective enrichment and determination of thrombin
- 1 October 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 845, 45-52
Aptamer-functionalized solid phase microextraction–liquid chromatography/tandem mass spectrometry for selective enrichment and determination of thrombin
- 6 July 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (18) , 4220-4225
Scanning positional variations in single-nucleotide polymorphism of DNA: an electrochemical study
While there are a number of electrochemical methods reported that enable the detection of single nucleotide mismatches, the determination of mismatch position in a double stranded DNA remains an unsolved challenge. Using a model system, we systematically explored the electrochemical response of all possible positions of single nucleotide mismatches in a set of 25-mer DNA films. These ds-DNA sequences each with a single mismatch at one of the twenty-five positions were bound to gold surfaces through a Au–S linkage and analyzed by electrochemical impedance spectroscopy (EIS) and scanning electrochemical microscopy (SECM) in the absence and presence of Zn2+. We expected a unique response from each mismatched sequence in order to discriminate the mismatch positions. A pattern emerges between the electrochemical signals and mismatch positions. The positions can be grouped broadly into positions that exhibit large differences between matched and mismatched DNA (around positions 5 and 9) and those that exhibit smaller differences (around positions 1, 13 and 23) in the charge transfer resistance ΔRct, evaluated by EIS, and the apparent rate constant k0, evaluated by SECM. To the best of our knowledge, this is the first study evaluating the electrochemical response of a single nucleotide mismatch as a function of mismatch positions along an oligonucleotide sequence.
- 6 July 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (18) , 4220-4225
Scanning positional variations in single-nucleotide polymorphism of DNA: an electrochemical study
While there are a number of electrochemical methods reported that enable the detection of single nucleotide mismatches, the determination of mismatch position in a double stranded DNA remains an unsolved challenge. Using a model system, we systematically explored the electrochemical response of all possible positions of single nucleotide mismatches in a set of 25-mer DNA films. These ds-DNA sequences each with a single mismatch at one of the twenty-five positions were bound to gold surfaces through a Au–S linkage and analyzed by electrochemical impedance spectroscopy (EIS) and scanning electrochemical microscopy (SECM) in the absence and presence of Zn2+. We expected a unique response from each mismatched sequence in order to discriminate the mismatch positions. A pattern emerges between the electrochemical signals and mismatch positions. The positions can be grouped broadly into positions that exhibit large differences between matched and mismatched DNA (around positions 5 and 9) and those that exhibit smaller differences (around positions 1, 13 and 23) in the charge transfer resistance ΔRct, evaluated by EIS, and the apparent rate constant k0, evaluated by SECM. To the best of our knowledge, this is the first study evaluating the electrochemical response of a single nucleotide mismatch as a function of mismatch positions along an oligonucleotide sequence.