To study the energy spectrum response of a CsI(Tl) detector, we fabricated a new scintillation detector by coupling a CsI (Tl) crystal with an avalanche photodiode (APD) . Then, we designed a new low-noise readout circuit for the detector. Finally, we analyzed the effects of both temperature and bias voltage on the energy spectrum response and evaluated the capability to identify nuclides by connecting the detector to the readout circuit. The research showed that the noise of the readout circuit was 608e, with the noise slope being 5.71e/pF . At 20oC, the detector achieved an excellent bias stability, the energy resolution reached an optimal value of 5.24% at a bias voltage of 370 V, thus proving a satisfactory performance. The signal-noise ratio reached 19:1 and the rise time of the output signals was 84 ns. The detector achieved an excellent energy spectrum response to 137Cs, 152Eu and 226Ra radioactive sources, demonstrating a strong capability of nuclide recognition distinguishing clearly each energy peak.Keywords
This publication has 14 references indexed in Scilit:
- Characteristics of a Silicon Avalanche Photodiode for the Near-IR Spectral RangeTechnical Physics Letters, 2019
- Analytical Description of Avalanche Photodiode Characteristics. An Overview: Part IIJournal of Communications Technology and Electronics, 2018
- New numerical evaluation of parallelepiped NaI(Tl) detector geometrical and total efficiencies using extended sourcesRadioprotection, 2017
- Analytical description of avalanche photodiode characteristics. An overview: Part IJournal of Communications Technology and Electronics, 2017
- A CsI low-temperature detector for dark matter searchAstroparticle Physics, 2016
- Development of a High-Sensitivity Radiation Detector for ChromatographyIEEE Transactions on Nuclear Science, 2011
- Small Size Integrated CsI(Tl) Spectrometer Efficiency and Properties Dependence on TemperatureIEEE Transactions on Nuclear Science, 2008
- Comparative Study of a CsI and a ZnSe(Te/O) Scintillation Detector’s Properties for a Gamma-ray MeasurementJournal of Nuclear Science and Technology, 2008
- Combined detectors based on ZnSe(Te), CsI(Tl) and Si-PIN-PD for separate detection of alpha, beta and gamma radiationIEEE Transactions on Nuclear Science, 2000
- Improved energy resolution for scintillator based gamma-ray detectors obtained using a CsI(Tl)/Si-PIN detectorReview of Scientific Instruments, 1997