Bilateral manipulandum to synthesize ground referenced and interlimb viscoelastic loads

Authors:

Abstract
The bilateral system was designed to study limb stiffness in different movement tasks. The mechatronics consists of two angular voice coil actuators (/spl plusmn/40 Nm) with embedded rotary (/spl plusmn/20/spl deg/) and torque sensors driven by voltage controlled current sources. DSP software routines to synthesize isotonic (preloads, stretches) as well as viscoelastic load schemes (Voigt model) were implemented for each sensor-actuator. The software further provides coupling of both sensor-actuators for interlimb loads as well as real-time video functions for experiment guidance. The system's performance was tested in forearm extensions against ground referenced and interlimb viscoelastic loads.

This publication has 4 references indexed in Scilit: