Bilateral manipulandum to synthesize ground referenced and interlimb viscoelastic loads
Authors:
- D. RafoltDRD. Rafolt
- H.P. TafernerHTH.P. Taferner
- M. FendMFM. Fend
- 25 August 2005
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Abstract
The bilateral system was designed to study limb stiffness in different movement tasks. The mechatronics consists of two angular voice coil actuators (/spl plusmn/40 Nm) with embedded rotary (/spl plusmn/20/spl deg/) and torque sensors driven by voltage controlled current sources. DSP software routines to synthesize isotonic (preloads, stretches) as well as viscoelastic load schemes (Voigt model) were implemented for each sensor-actuator. The software further provides coupling of both sensor-actuators for interlimb loads as well as real-time video functions for experiment guidance. The system's performance was tested in forearm extensions against ground referenced and interlimb viscoelastic loads.Keywords
This publication has 4 references indexed in Scilit:
- Instrumentation for assessment of tremor, skin vibrations, and cardiovascular variables in MIR space missionsIEEE Transactions on Biomedical Engineering, 1996
- Portable system for quantifying motor abnormalities in Parkinson's diseaseIEEE Transactions on Biomedical Engineering, 1993
- A perceptual analysis of stiffnessExperimental Brain Research, 1990
- What muscle variable(s) does the nervous system control in limb movements?Behavioral and Brain Sciences, 1982