Dietmar Rafolt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dietmar Rafolt has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
E. Gallasch
7 shared publications- Monica Christova
Otto Loewi Research Center, Physiology Section, Medical University of Graz, Graz, Austria
3 shared publications T. Kenner
University of Graz
2 shared publicationsA Konev
1 shared publicationE Gallasch
Dept. of Physiology, University of Graz, Austria
1 shared publicationEugen Gallasch
Department of Physiology, University of Graz, Graz, Austria
1 shared publication
Latest Publications
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 322
Transcranial direct current stimulation improves pegboard test performance and has a positive effect on motor memory
- 1 March 2015
- Published by Elsevier in Brain Stimulation
- Vol. 8 (2) , 322
Transcranial direct current stimulation improves pegboard test performance and has a positive effect on motor memory
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 163-166
Transcranial Magnetic Stimulation to Elicit Changes in Motor Cortex Excitability during Haptic Training
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 163-166
Transcranial Magnetic Stimulation to Elicit Changes in Motor Cortex Excitability during Haptic Training
- 31 July 2008
- Published by Elsevier in Brain Stimulation
- Vol. 1 (3) , 290
Hemispheric differences in motor cortex excitability during training of a novel goal-directed motor task
- 31 July 2008
- Published by Elsevier in Brain Stimulation
- Vol. 1 (3) , 290
Hemispheric differences in motor cortex excitability during training of a novel goal-directed motor task
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Bilateral manipulandum to synthesize ground referenced and interlimb viscoelastic loads
The bilateral system was designed to study limb stiffness in different movement tasks. The mechatronics consists of two angular voice coil actuators (/spl plusmn/40 Nm) with embedded rotary (/spl plusmn/20/spl deg/) and torque sensors driven by voltage controlled current sources. DSP software routines to synthesize isotonic (preloads, stretches) as well as viscoelastic load schemes (Voigt model) were implemented for each sensor-actuator. The software further provides coupling of both sensor-actuators for interlimb loads as well as real-time video functions for experiment guidance. The system's performance was tested in forearm extensions against ground referenced and interlimb viscoelastic loads.
- 25 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Bilateral manipulandum to synthesize ground referenced and interlimb viscoelastic loads
The bilateral system was designed to study limb stiffness in different movement tasks. The mechatronics consists of two angular voice coil actuators (/spl plusmn/40 Nm) with embedded rotary (/spl plusmn/20/spl deg/) and torque sensors driven by voltage controlled current sources. DSP software routines to synthesize isotonic (preloads, stretches) as well as viscoelastic load schemes (Voigt model) were implemented for each sensor-actuator. The software further provides coupling of both sensor-actuators for interlimb loads as well as real-time video functions for experiment guidance. The system's performance was tested in forearm extensions against ground referenced and interlimb viscoelastic loads.
- 1 September 2002
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (5) , 594-599
Surface myomechanical responses recorded on a scanner galvanometer.
- 1 September 2002
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (5) , 594-599
Surface myomechanical responses recorded on a scanner galvanometer.
- 1 May 1999
- Published by Wiley in Artificial Organs
- Vol. 23 (5) , 436-439
Dynamic Force Responses in Electrically Stimulated Triceps Surae Muscles: Effects of Fatigue and Temperature
- 1 May 1999
- Published by Wiley in Artificial Organs
- Vol. 23 (5) , 436-439
Dynamic Force Responses in Electrically Stimulated Triceps Surae Muscles: Effects of Fatigue and Temperature
- 1 March 1997
- Vol. 21 (3) , 210-2
Useful applications and limits of battery powered implants in functional electrical stimulations.
Battery powered stimulation implants have been well-known for a long time as heart pacemakers. In the last few years, fully implantable stimulators have been used in the field of functional electrical stimulation (FES) for applications like dynamic cardiomyoplasty and electro-stimulated graciloplasty for fecal incontinence. The error rate of battery powered implants is significantly smaller than that for conventional stimulator systems, and the quality of life for the patients is increased because the need for an external power and control unit is eliminated. The use of battery powered implants is limited by the complexity of the stimulation control strategies and the battery capacity. Therefore, applications like the stimulation of lower extremities for walking, cochlea stimulation, or direct muscle stimulation cannot be supported. The improvement of implantable batteries, microcontrollers, and ultralow power products is ongoing. In the future, battery powered implants will also meet the requirements of complex applications. Systems for restoration of hand and breathing functions after spinal cord injury can be the next field of use for battery powered implants. For these purposes, we developed a battery powered multichannel implant with a sufficient life span for phrenic pacing. The problems during development and the limits of this system are described in this paper.
- 1 March 1997
- Vol. 21 (3) , 210-2
Useful applications and limits of battery powered implants in functional electrical stimulations.
Battery powered stimulation implants have been well-known for a long time as heart pacemakers. In the last few years, fully implantable stimulators have been used in the field of functional electrical stimulation (FES) for applications like dynamic cardiomyoplasty and electro-stimulated graciloplasty for fecal incontinence. The error rate of battery powered implants is significantly smaller than that for conventional stimulator systems, and the quality of life for the patients is increased because the need for an external power and control unit is eliminated. The use of battery powered implants is limited by the complexity of the stimulation control strategies and the battery capacity. Therefore, applications like the stimulation of lower extremities for walking, cochlea stimulation, or direct muscle stimulation cannot be supported. The improvement of implantable batteries, microcontrollers, and ultralow power products is ongoing. In the future, battery powered implants will also meet the requirements of complex applications. Systems for restoration of hand and breathing functions after spinal cord injury can be the next field of use for battery powered implants. For these purposes, we developed a battery powered multichannel implant with a sufficient life span for phrenic pacing. The problems during development and the limits of this system are described in this paper.
- 1 May 1994
- Vol. 1 (1) , P52-4
Physiological tremor and control of limb position in 1 and 0 G.
Muscle and skeletal mechanoreceptors play an important role for the regulation of muscular tone and the genesis of normal Physiological Tremor (PT). For example if a big limb as the arm or leg is kept against the gravity vector, the la afferent spindle discharges continuously control the load bearing flexor in a negative feedback manner in order to compensate the gravity vector and to the stabilize arm position. This servo-like action, denoted as 'stretch reflex', not only increases static postural stability (tonic stretch reflex) but also counteracts against external disturbances by dynamically increasing the muscle tone. Muscle spindles are very sophisticated sensory organs. They have an own innervation and the endings of the nuclear bag fibres are highly sensitive for small microstretches. EMG and microneurografic studies showed their importance in the mechanism of the 8-12 Hz component for PT. In a 0 G a limb becomes position controlled. In contrast to 1g, where control of limb position is a subordinated function of force compensation in the load bearing muscle, an antagonistic control scheme is necessary in 0 G to compensate the arm against positional drifts. As a consequence there is a shift from load dependent (muscular) to position dependent (skeletal) mechanoreceptors that become involved in the neural control process. As the control process is reflected in the tremor pattern, we investigated arm tremor in a constant limb position in 1 and 0 G.
- 1 May 1994
- Vol. 1 (1) , P52-4
Physiological tremor and control of limb position in 1 and 0 G.
Muscle and skeletal mechanoreceptors play an important role for the regulation of muscular tone and the genesis of normal Physiological Tremor (PT). For example if a big limb as the arm or leg is kept against the gravity vector, the la afferent spindle discharges continuously control the load bearing flexor in a negative feedback manner in order to compensate the gravity vector and to the stabilize arm position. This servo-like action, denoted as 'stretch reflex', not only increases static postural stability (tonic stretch reflex) but also counteracts against external disturbances by dynamically increasing the muscle tone. Muscle spindles are very sophisticated sensory organs. They have an own innervation and the endings of the nuclear bag fibres are highly sensitive for small microstretches. EMG and microneurografic studies showed their importance in the mechanism of the 8-12 Hz component for PT. In a 0 G a limb becomes position controlled. In contrast to 1g, where control of limb position is a subordinated function of force compensation in the load bearing muscle, an antagonistic control scheme is necessary in 0 G to compensate the arm against positional drifts. As a consequence there is a shift from load dependent (muscular) to position dependent (skeletal) mechanoreceptors that become involved in the neural control process. As the control process is reflected in the tremor pattern, we investigated arm tremor in a constant limb position in 1 and 0 G.
- 1 January 1994
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 615
Head mounted accelerometers in the control of a video cursor
- 1 January 1994
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 615
Head mounted accelerometers in the control of a video cursor
- 1 January 1992
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 37 (s1) , 167-169
Neue optische, mechanische und optomechanische Pulssensoren für die nichtinvasive Pulskurvenaufzeichnung an den Akren und großen Arterien
- 1 January 1992
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 37 (s1) , 167-169
Neue optische, mechanische und optomechanische Pulssensoren für die nichtinvasive Pulskurvenaufzeichnung an den Akren und großen Arterien