Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study (Preprint)
Authors:
- Ravi Kondama ReddyRRRavi Kondama Reddy
- Rubin PooniRPRubin Pooni
- Dessi P ZaharievaDZDessi P Zaharieva
- Brian SenfBSBrian Senf
- Joseph El YoussefJYJoseph El Youssef
- Eyal DassauEDEyal Dassau
- Francis J Doyle IiiFIFrancis J Doyle Iii
- Mark A ClementsMCMark A Clements
- Michael R RickelsMRMichael R Rickels
- Susana R PattonSPSusana R Patton
- Jessica R CastleJCJessica R Castle
- Michael C RiddellMRMichael C Riddell
Preprint
- 19 March 2018
- preprint
- Published by JMIR Publications Inc. in JMIR Preprints
Abstract
BACKGROUND Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings including more recently in medical applications. The use of real-time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured, including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady-state aerobic exercise. OBJECTIVE The objective of this study was to validate the accuracy of both HR and EE for 2 common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. METHODS We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) during dynamic activities. Over a 2-day period, 20 healthy adults (age: mean 27.5 [SD 6.0] years; body mass index: mean 22.5 [SD 2.3] kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using an HR chest strap (Polar) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. RESULTS Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (RE, %) of −3.3% (SD 16.7), whereas Fitbit estimated HR with an RE of −4.7% (SD 19.6) across all activities. The highest error was observed during high-intensity intervals on bike (Fitbit: −11.4% [SD 35.7]; Garmin: −14.3% [SD 20.5]) and lowest error during high-intensity intervals on treadmill (Fitbit: −1.7% [SD 11.5]; Garmin: −0.5% [SD 9.4]). Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: −19.3% [SD 28.9], Garmin: −1.6% [SD 30.6], P<.001) across all activities, and with both correlating poorly with indirect calorimetry measures. CONCLUSIONS Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.Keywords
All Related Versions
- Published version: JMIR mHealth and uHealth, 6 (12), e10338.
This publication has 21 references indexed in Scilit:
- Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HRJournal of Sports Sciences, 2017
- Closed-Loop Control During Intense Prolonged Outdoor Exercise in Adolescents With Type 1 Diabetes: The Artificial Pancreas Ski StudyDiabetes Care, 2017
- The Effects of Basal Insulin Suspension at the Start of Exercise on Blood Glucose Levels During Continuous Versus Circuit-Based Exercise in Individuals with Type 1 Diabetes on Continuous Subcutaneous Insulin InfusionDiabetes Technology & Therapeutics, 2017
- Outpatient Closed-Loop Control with Unannounced Moderate Exercise in Adolescents Using Zone Model Predictive ControlDiabetes Technology & Therapeutics, 2017
- Exercise management in type 1 diabetes: a consensus statementThe Lancet Diabetes & Endocrinology, 2017
- Randomized trial of a dual‐hormone artificial pancreas with dosing adjustment during exercise compared with no adjustment and sensor‐augmented pump therapyDiabetes, Obesity and Metabolism, 2016
- Incorporating an Exercise Detection, Grading, and Hormone Dosing Algorithm Into the Artificial Pancreas Using Accelerometry and Heart RateJournal of Diabetes Science and Technology, 2015
- Validity of Consumer-Based Physical Activity MonitorsMedicine & Science in Sports & Exercise, 2014
- Adding Heart Rate Signal to a Control-to-Range Artificial Pancreas System Improves the Protection Against Hypoglycemia During Exercise in Type 1 DiabetesDiabetes Technology & Therapeutics, 2014
- An Integrated Multivariable Artificial Pancreas Control SystemJournal of Diabetes Science and Technology, 2014