JYJoseph El Youssef

Joseph El Youssef

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseph El Youssef has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantifying insulin-mediated and noninsulin-mediated changes in glucose dynamics during resistance exercise in type 1 diabetes

    by Gavin M. Young, Peter G. Jacobs, Nichole S. Tyler, Thanh-Tin P. Nguyen, Jessica R. Castle, Leah M. Wilson, Deborah Branigan, Virginia Gabo, Florian H. Guillot, Michael C. Riddell, et al.

    Aerobic exercise is known to cause decreases in blood glucose secondary to increased glucose utilization in people living with type 1 diabetes (T1D). However, less is known about how resistance-type exercise impacts glucose dynamics. Twenty-five participants with T1D performed in-clinic weight-bearing exercises under a glucose clamp. Mathematical modeling of infused glucose tracer allowed for quantification of the rate of hepatic glucose production as well as rates of insulin-mediated and noninsulin-mediated glucose uptake experienced during resistance exercise.


  • Open Access

    Quantifying the impact of physical activity on future glucose trends using machine learning

    by Nichole S. Tyler, Clara Mosquera-Lopez, Gavin M. Young, Joseph El Youssef, Jessica R. Castle, Peter G. Jacobs


  • Separating insulin-mediated and non-insulin-mediated glucose uptake during and after aerobic exercise in type 1 diabetes

    by Thanh-Tin P. Nguyen, Peter G. Jacobs, Jessica R. Castle, Leah M. Wilson, Kerry Kuehl, Deborah Branigan, Virginia Gabo, Florian Guillot, Michael C. Riddell, Ahmad Haidar, et al.

    Aerobic exercise in type 1 diabetes (T1D) causes rapid increase in glucose utilization due to muscle work during exercise, followed by increased insulin resistance after exercise. Better understanding of these changes is necessary for models of exercise in T1D. Twenty-six individuals with T1D underwent three studies at three insulin rates (100%, 150%, 300% of basal). After 3-hours run-in, participants performed 45 minutes aerobic exercise (moderate or intense). We determined area-under-the-curve for endogenous glucose production (AUCEGP) and rate of glucose disappearance (AUCRd) over 45 minutes from exercise start. A novel application of linear regression of Rd across the three insulin studies allowed separation of insulin-mediated from non-insulin-mediated glucose uptake before, during and after exercise. ­AUCRd increased 12.45 mmol/L (CI=10.33-14.58, pEGP increased 1.66(CI=1.01-2.31, pEGP increased during intense exercise by 2.14 mmol/L (CI=0.91-3.37, pRd equal to 0.06 mmol/L per % above basal rate (CI=0.05-0.07, p<0.001). Insulin-mediated glucose uptake rose during exercise and persisted hours afterward, while non-insulin mediated effect was limited to the exercise period. To our knowledge, this method of isolating dynamic insulin and non-insulin mediated uptake has not been previously employed during exercise. These results will be useful in informing glucoregulatory models of T1D. The study has been registered at www.clinicaltrials.gov (ID: NCT03090451).


  • Predicting and Preventing Nocturnal Hypoglycemia in Type 1 Diabetes Using Big Data Analytics and Decision Theoretic Analysis

    by Clara Mosquera-Lopez, Robert Dodier, Nichole S. Tyler, Leah M. Wilson, Joseph El Youssef, Jessica R. Castle, Peter G. Jacobs

    Background: Despite new glucose sensing technologies, nocturnal hypoglycemia is still a problem for people with type 1 diabetes (T1D) as symptoms and sensor alarms may not be detected while sleeping. Accurately predicting nocturnal hypoglycemia before sleep may help minimize nighttime hypoglycemia. Methods: A support vector regression (SVR) model was trained to predict, before bedtime, the overnight minimum glucose and overnight nocturnal hypoglycemia for people with T1D. The algorithm was trained on continuous glucose measurements and insulin data collected from 124 people (22,804 valid nights of data) with T1D. The minimum glucose threshold for announcing nocturnal hypoglycemia risk was derived by applying a decision theoretic criterion to maximize expected net benefit. Accuracy was evaluated on a validation set from 10 people with T1D during a 4-week trial under free-living sensor-augmented insulin-pump therapy. The primary outcome measures were sensitivity and specificity of prediction, the correlation between predicted and actual minimum nocturnal glucose, and root-mean-square error. The impact of using the algorithm to prevent nocturnal hypoglycemia is shown in-silico. Results: The algorithm predicted 94.1% of nocturnal hypoglycemia events (R = 0.71, P < 0.001). In-silico simulations showed that the algorithm could reduce nocturnal hypoglycemia by 77.0% ( P = 0.006) without impacting time in target range (3.9–10 mmol/L). Conclusion: An SVR model trained on a big data set and optimized using decision theoretic criterion can accurately predict at bedtime if overnight nocturnal hypoglycemia will occur and may help reduce nocturnal hypoglycemia.


  • Open Access

    Accuracy of the Dexcom G6 Glucose Sensor during Aerobic, Resistance, and Interval Exercise in Adults with Type 1 Diabetes

    by Florian H. Guillot, Peter G. Jacobs, Leah M. Wilson, Joseph El Youssef, Virginia B. Gabo, Deborah L. Branigan, Nichole S. Tyler, Katrina Ramsey, Michael C. Riddell, Jessica R. Castle

    The accuracy of continuous glucose monitoring (CGM) sensors may be significantly impacted by exercise. We evaluated the impact of three different types of exercise on the accuracy of the Dexcom G6 sensor. Twenty-four adults with type 1 diabetes on multiple daily injections wore a G6 sensor. Participants were randomized to aerobic, resistance, or high intensity interval training (HIIT) exercise. Each participant completed two in-clinic 30-min exercise sessions. The sensors were applied on average 5.3 days prior to the in-clinic visits (range 0.6–9.9). Capillary blood glucose (CBG) measurements with a Contour Next meter were performed before and after exercise as well as every 10 min during exercise. No CGM calibrations were performed. The median absolute relative difference (MARD) and median relative difference (MRD) of the CGM as compared with the reference CBG did not differ significantly from the start of exercise to the end exercise across all exercise types (ranges for aerobic MARD: 8.9 to 13.9% and MRD: −6.4 to 0.5%, resistance MARD: 7.7 to 14.5% and MRD: −8.3 to −2.9%, HIIT MARD: 12.1 to 16.8% and MRD: −14.3 to −9.1%). The accuracy of the no-calibration Dexcom G6 CGM was not significantly impacted by aerobic, resistance, or HIIT exercise.


  • Effect of Aerobic and Resistance Exercise on Glycemic Control in Adults With Type 1 Diabetes

    by Ravi Reddy, Amanda Wittenberg, Jessica R. Castle, Joseph El Youssef, Kerri Winters-Stone, Melanie Gillingham, Peter G. Jacobs


  • Open Access

    Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study

    by Ravi Kondama Reddy, Rubin Pooni, Dessi P Zaharieva, Brian Senf, Joseph El Youssef, Eyal Dassau, Francis J Doyle Iii, Mark A Clements, Michael R Rickels, Susana R Patton, et al.

    Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings, including more recently in medical applications. The use of real time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady state aerobic exercise. Objective: The objective of this study was to validate the accuracy of both HR and EE for two common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. Methods: We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2TM, Garmin vívosmart® HR+) during dynamic activities. Over a two-day period, 20 healthy adults (age: 27.5 ± 6.0 yrs; BMI: 22.5 ± 2.3 kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using a HR chest strap (Polar®) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. Results: Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high intensity activities, when there was a lack of repetitive wrist motion, and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (%RE) of -3.3% ± 16.7 while Fitbit estimated HR with a %RE of -4.7% ± 19.6 across all activities. The highest error was observed during high intensity intervals on bike (Fitbit: -11.4% ± 35.7; Garmin: -14.3% ± 20.5) and lowest error during high intensity intervals on treadmill (Fitbit: -1.7% ± 11.5; Garmin: -0.5% ± 9.4). Fitbit and Garmin EE estimates differed significantly with Garmin having less negative bias (Fitbit: -19.3% ± 29.9, Garmin: -1.6% ± 30.6, P<.001) across all activities, with both correlating poorly with indirect calorimetry measures. Conclusions: Two common wrist-worn devices show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.


  • Open Access

    Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study (Preprint)

    by Ravi Kondama Reddy, Rubin Pooni, Dessi P Zaharieva, Brian Senf, Joseph El Youssef, Eyal Dassau, Francis J Doyle Iii, Mark A Clements, Michael R Rickels, Susana R Patton, et al.

    BACKGROUND Wrist-worn activity monitors are often used to monitor heart rate (HR) and energy expenditure (EE) in a variety of settings including more recently in medical applications. The use of real-time physiological signals to inform medical systems including drug delivery systems and decision support systems will depend on the accuracy of the signals being measured, including accuracy of HR and EE. Prior studies assessed accuracy of wearables only during steady-state aerobic exercise. OBJECTIVE The objective of this study was to validate the accuracy of both HR and EE for 2 common wrist-worn devices during a variety of dynamic activities that represent various physical activities associated with daily living including structured exercise. METHODS We assessed the accuracy of both HR and EE for two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) during dynamic activities. Over a 2-day period, 20 healthy adults (age: mean 27.5 [SD 6.0] years; body mass index: mean 22.5 [SD 2.3] kg/m2; 11 females) performed a maximal oxygen uptake test, free-weight resistance circuit, interval training session, and activities of daily living. Validity was assessed using an HR chest strap (Polar) and portable indirect calorimetry (Cosmed). Accuracy of the commercial wearables versus research-grade standards was determined using Bland-Altman analysis, correlational analysis, and error bias. RESULTS Fitbit and Garmin were reasonably accurate at measuring HR but with an overall negative bias. There was more error observed during high-intensity activities when there was a lack of repetitive wrist motion and when the exercise mode indicator was not used. The Garmin estimated HR with a mean relative error (RE, %) of −3.3% (SD 16.7), whereas Fitbit estimated HR with an RE of −4.7% (SD 19.6) across all activities. The highest error was observed during high-intensity intervals on bike (Fitbit: −11.4% [SD 35.7]; Garmin: −14.3% [SD 20.5]) and lowest error during high-intensity intervals on treadmill (Fitbit: −1.7% [SD 11.5]; Garmin: −0.5% [SD 9.4]). Fitbit and Garmin EE estimates differed significantly, with Garmin having less negative bias (Fitbit: −19.3% [SD 28.9], Garmin: −1.6% [SD 30.6], P<.001) across all activities, and with both correlating poorly with indirect calorimetry measures. CONCLUSIONS Two common wrist-worn devices (Fitbit Charge 2 and Garmin vívosmart HR+) show good HR accuracy, with a small negative bias, and reasonable EE estimates during low to moderate-intensity exercise and during a variety of common daily activities and exercise. Accuracy was compromised markedly when the activity indicator was not used on the watch or when activities involving less wrist motion such as cycle ergometry were done.

  • Factors affecting the success of glucagon delivered during an automated closed-loop system in type 1 diabetes

    by P.A. Bakhtiani, J. El Youssef, A.K. Duell, D.L. Branigan, P.G. Jacobs, M.R. Lasarev, J.R. Castle, W.K. Ward