An Adaptive Reclosing Scheme for Cross-Line Faults on Double-Circuit Wind Power Outgoing Lines with Shunt Reactors
Open Access
Abstract
Wind turbines are vulnerable to negative sequence current injection, the conventional automatic reclosing scheme for wind power outgoing lines, since we may inject negative sequence components into the system and reclose it without distinguishing the nature of the fault through rectification. Moreover, reclosing in permanent faults could induce a secondary impact on the system. To solve the above problems, an adaptive reclosing scheme for cross-line faults on double-circuit wind power outgoing lines with shunt reactors is proposed. Firstly, a new tripping strategy and a single-side partial-phase reclosing method are proposed for multiple types of outgoing line faults, while, simultaneously, phase-to-phase coupling loops are established. Secondly, the criteria of fault nature are established based on the fault phase shunt reactor current and fault phase voltage characteristics, and transient faults are rapidly and accurately distinguished from permanent ones according to the criteria. Finally, the theoretical derivation and simulation experiments are conducted on the PSCAD/EMTDC platform to demonstrate that the proposed adaptive reclosing method is applicable to avoid the injection of negative sequence currents into wind turbines. Meanwhile, the success rate of reclosing for wind power outgoing line is significantly improved and the continuity of power transmission on the wind farm(s) is ensured.Keywords
Funding Information
- National Key R&D Program (2021YFB1507001)
This publication has 25 references indexed in Scilit:
- Adaptive Autoreclosing Scheme for Line-to-Line Nongrounded Faults on Double-Circuit Transmission Lines Based on Phase-to-Phase Reactive PowerIEEE Access, 2020
- Study on Three-Phase Reclosing Strategy Applicable to Tie Line of Photovoltaic Power StationIEEE Access, 2020
- Online parameter determination based adaptive single‐phase reclosing scheme for wind‐powered outgoing lines with shunt reactorsIET Renewable Power Generation, 2019
- Algorithm for adaptive single‐phase reclosure on shunt‐reactor compensated extra high voltage transmission lines considering beat frequency oscillationIET Generation, Transmission & Distribution, 2018
- A New Intelligent Autoreclosing Scheme Using Artificial Neural Network and Taguchi's MethodologyIEEE Transactions on Industry Applications, 2010
- New approach to adaptive single pole auto-reclosing of power transmission linesIET Generation, Transmission & Distribution, 2010
- Digital fault location for parallel double-circuit multi-terminal transmission linesIEEE Transactions on Power Delivery, 2000
- Adaptive distance protection of double-circuit lines using artificial neural networksIEEE Transactions on Power Delivery, 1997
- Intelligent reclosing for overdutied breakersIEEE Transactions on Power Delivery, 1995
- Adaptive transmission relaying concepts for improved performanceIEEE Transactions on Power Delivery, 1988