Performance and Safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) in Phakic Subjects with Presbyopia
Open Access
- 1 September 2020
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2717-2730
Abstract
Purpose: To evaluate the performance and safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) for improvement of uncorrected near, intermediate and distance visual acuity in phakic subjects with myopia and presbyopia. Design: Prospective multicenter study. Methods: Presbyopic subjects who required an EDOF ICL in the range of − 0.50 D to − 18.00 D, exhibited ≤ 0.75 D refractive astigmatism and required from +1.00 to +2.50 D reading add were implanted bilaterally. Assessments at 6 months included uncorrected near, intermediate and distance visual acuities, defocus curves, contrast sensitivity, responses to the National Eye Institute Refractive Error Quality of Life Questionnaire and a Task Assessment Questionnaire. Results: A total of 34 subjects completed the study. Investigators targeted emmetropia in all eyes. Mean binocular uncorrected near, intermediate and distance visual acuities measured logMAR − 0.01 ± 0.05 (20/20), − 0.02 ± 0.08 (20/19) and 0.07 ± 0.10 (20/23), respectively. Mean monocular uncorrected near, intermediate and distance visual acuities measured logMAR 0.068 ± 0.09 (20/23), 0.062 ± 0.10 (20/23) and 0.16 ± 0.12 (20/29). There were no clinically or statistically significant differences in contrast sensitivity between baseline and 6 months under any testing conditions. Subjects reported significant improvements in measures of vision-related quality of life and ability to perform tasks at all distances without glasses or contact lenses. Overall, satisfaction with the EDOF ICL was high: postoperatively, 91.2% of subjects were satisfied with their vision. Conclusion: This multicenter, prospective clinical investigation demonstrated the ability of the EDOF ICL to correct myopia and presbyopia, resulting in improvement of uncorrected near, intermediate and distance visual acuity without compromising the quality of vision. The EDOF ICL allowed subjects to perform tasks of daily living without glasses or contact lenses. Subjects reported significant improvements in quality of life with high levels of spectacle independence and satisfaction.Keywords
This publication has 17 references indexed in Scilit:
- Monovision LASIK Versus Presbyopia-Correcting IOLs: Comparison of Clinical and Patient-Reported OutcomesJournal of Refractive Surgery, 2017
- Pseudophakic retinal detachment in young-aged patientsPLOS ONE, 2017
- Reading charts in ophthalmologyGraefe's Archive for Clinical and Experimental Ophthalmology, 2017
- Safety and effectiveness of the SUPRACOR presbyopic LASIK algorithm on hyperopic patientsEye and Vision, 2016
- Modern Phacoemulsification and Intraocular Lens Implantation (Refractive Lens Exchange) Is Safe and Effective in Treating High MyopiaAsia-Pacific Journal of Ophthalmology, 2016
- One-Year Safety and Efficacy Results of a Hydrogel Inlay to Improve Near Vision in Patients With Emmetropic PresbyopiaJournal of Refractive Surgery, 2013
- LASIK for Presbyopia Correction in Emmetropic Patients Using Aspheric Ablation Profiles and a Micro-monovision Protocol With the Carl Zeiss Meditec MEL 80 and VisuMaxJournal of Refractive Surgery, 2012
- The Quality of Life Associated with PresbyopiaAmerican Journal of Ophthalmology, 2008
- Psychometric properties of the National Eye Institute–Refractive Error Quality of Life instrumentOphthalmology, 2003
- Associations of Presbyopia With Vision-Targeted Health-Related Quality of LifeArchives of Ophthalmology (1950), 2003