Erik Mertens
Research Subjects
Erik Mertens has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Daniel Elies
2 shared publicationsDavid Shahnazaryan
Centre for Sight, London, UK
2 shared publications- Francesco Carones
Advalia, Milan, Italy
2 shared publications Jaime Aramberri
2 shared publicationsJoaquin Fernandez
2 shared publications- José Fernando Alfonso
Instituto Oftalmológico Fernández-Vega, Oviedo, Spain
2 shared publications
Latest Publications
- 1 August 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (8) , 746
Comment on: From the editor. Current and future nomenclature and categorization of intraocular lenses
An abstract is unavailable. This article is available as a PDF only.
- 1 August 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (8) , 746
Comment on: From the editor. Current and future nomenclature and categorization of intraocular lenses
An abstract is unavailable. This article is available as a PDF only.
- Open Access
- 1 June 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1945-1956
Evaluating the Predictive Accuracy of an AI-Based Tool for Postoperative Vault Estimation in Phakic Intraocular Lens Implantation
Introduction: Phakic intraocular lenses are widely used for refractive error correction, with the EVO ICL delivering excellent visual outcomes. Achieving an optimal postoperative vault is critical to minimize complications. The purpose of this study was to evaluate the predictive accuracy of an AI-based tool that integrates high-resolution ultrasound biomicroscopy (UBM) imaging with biometric data, for estimating postoperative vault in myopic patients. Settings: The study was performed at four centers: Instituto Zaldivar (Argentina), Wellington Eye Clinic (Ireland), Medipolis Eye Center (Belgium), and Asian Eye Institute (Philippines). Methods: In this retrospective, multicenter study, 347 eyes from 228 myopic patients (mean age 31.3 ± 7.7 years) underwent ICL implantation. Preoperative biometric parameters and UBM imaging were utilized to generate vault predictions using the AI-based tool. Predicted vault values were compared with clinical measurements obtained at 1 day and 1 month postoperatively. Statistical analyses, including Spearman correlation and multivariable linear regression, were conducted to assess the agreement between predicted and measured vaults and to identify significant predictive factors. Results: At 1 day postoperatively, the mean clinical vault was 520.97 ± 178.73 μm versus a predicted vault of 508.16 ± 163.00 μm, with a mean signed difference of − 12.81 μm (r²=0.621, p< 0.001). Subgroup analyses across the four centers demonstrated stable predictions, with no significant inter-center differences in either clinical or predicted vault measurements (p> 0.05). Multivariable regression identified ARise and spherical power as significant predictors of vault discrepancy, with uniform effects across diverse populations. Conclusion: The ICLGuru™ reliably predicts postoperative vault with clinically acceptable accuracy. These findings underscore the generalizability and reliable performance of the AI-based tool across varied clinical settings. Its integration into preoperative planning may enhance ICL sizing and reduce complications in myopic patients. Plain Language Summary: Phakic intraocular Collamer lenses (ICLs) are special lenses implanted in the eye to correct vision problems like nearsightedness. Choosing the right size is crucial to ensure the lens fits well and does not cause complications. Doctors currently use different methods to estimate the best lens size, but these are not always perfect. This study tested a new artificial intelligence (AI) tool that predicts how much space (or “vault”) will be left between the implanted lens and the eye’s natural structures after surgery. The aim is to know if this tool could accurately estimate the vault before surgery, helping doctors choose the right lens size. To find out, 347 eyes from 228 patients who had ICL surgery in four different eye clinics around the world were analyzed. The AI tool used high-resolution ultrasound images and biometric data (measurements of the eye) to predict the vault. These predictions were then compared with actual vault measurements taken after surgery. The results showed that the AI-based tool was highly accurate, with only a small difference between predicted and actual vault values. The tool worked well across different patient groups and clinic locations. The study also identified factors, such as the shape of the eye, that slightly affected prediction accuracy. These findings suggest that AI can help eye surgeons make better decisions about lens sizing, potentially reducing the risk of complications and improving surgical outcomes for patients.
- 1 June 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1945-1956
Open AccessEvaluating the Predictive Accuracy of an AI-Based Tool for Postoperative Vault Estimation in Phakic Intraocular Lens Implantation
Introduction: Phakic intraocular lenses are widely used for refractive error correction, with the EVO ICL delivering excellent visual outcomes. Achieving an optimal postoperative vault is critical to minimize complications. The purpose of this study was to evaluate the predictive accuracy of an AI-based tool that integrates high-resolution ultrasound biomicroscopy (UBM) imaging with biometric data, for estimating postoperative vault in myopic patients. Settings: The study was performed at four centers: Instituto Zaldivar (Argentina), Wellington Eye Clinic (Ireland), Medipolis Eye Center (Belgium), and Asian Eye Institute (Philippines). Methods: In this retrospective, multicenter study, 347 eyes from 228 myopic patients (mean age 31.3 ± 7.7 years) underwent ICL implantation. Preoperative biometric parameters and UBM imaging were utilized to generate vault predictions using the AI-based tool. Predicted vault values were compared with clinical measurements obtained at 1 day and 1 month postoperatively. Statistical analyses, including Spearman correlation and multivariable linear regression, were conducted to assess the agreement between predicted and measured vaults and to identify significant predictive factors. Results: At 1 day postoperatively, the mean clinical vault was 520.97 ± 178.73 μm versus a predicted vault of 508.16 ± 163.00 μm, with a mean signed difference of − 12.81 μm (r²=0.621, p< 0.001). Subgroup analyses across the four centers demonstrated stable predictions, with no significant inter-center differences in either clinical or predicted vault measurements (p> 0.05). Multivariable regression identified ARise and spherical power as significant predictors of vault discrepancy, with uniform effects across diverse populations. Conclusion: The ICLGuru™ reliably predicts postoperative vault with clinically acceptable accuracy. These findings underscore the generalizability and reliable performance of the AI-based tool across varied clinical settings. Its integration into preoperative planning may enhance ICL sizing and reduce complications in myopic patients. Plain Language Summary: Phakic intraocular Collamer lenses (ICLs) are special lenses implanted in the eye to correct vision problems like nearsightedness. Choosing the right size is crucial to ensure the lens fits well and does not cause complications. Doctors currently use different methods to estimate the best lens size, but these are not always perfect. This study tested a new artificial intelligence (AI) tool that predicts how much space (or “vault”) will be left between the implanted lens and the eye’s natural structures after surgery. The aim is to know if this tool could accurately estimate the vault before surgery, helping doctors choose the right lens size. To find out, 347 eyes from 228 patients who had ICL surgery in four different eye clinics around the world were analyzed. The AI tool used high-resolution ultrasound images and biometric data (measurements of the eye) to predict the vault. These predictions were then compared with actual vault measurements taken after surgery. The results showed that the AI-based tool was highly accurate, with only a small difference between predicted and actual vault values. The tool worked well across different patient groups and clinic locations. The study also identified factors, such as the shape of the eye, that slightly affected prediction accuracy. These findings suggest that AI can help eye surgeons make better decisions about lens sizing, potentially reducing the risk of complications and improving surgical outcomes for patients.
- 1 May 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (5) , 436
Comment on: Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group
An abstract is unavailable. This article is available as a PDF only.
- 1 May 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (5) , 436
Comment on: Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group
An abstract is unavailable. This article is available as a PDF only.
- 18 May 2023
- Published by Springer Nature
- p. 813-817
Management of Surgical Complications When Implanting Phakic IOLs
- 18 May 2023
- Published by Springer Nature
- p. 813-817
Management of Surgical Complications When Implanting Phakic IOLs
- Open Access
- 14 October 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (2) , 126-132
Postoperative vault prediction for phakic implantable collamer lens surgery: LASSO formulas
Purpose: To develop and evaluate reliable formulas for predicting postoperative vault more accurately after implantable collamer lens (ICL) surgery in a White patient population with varying degrees of ametropia. Setting: Private clinical practice. Design: Retrospective analysis on dataset split into a separate training and test set. Methods: 115 eyes of 59 patients were used to train regression models predicting postoperative vault based on anterior segment optical coherence tomography (OCT) parameters (Least Absolute Shrinkage and Selection Operator [LASSO]-OCT formula), ocular biometry data (LASSO-Biometry formula), or data from both devices (LASSO-Full formula). The performance of these models was evaluated against the manufacturer's nomogram (Online Calculation and Ordering System [OCOS]) and Nakamura 1 (NK1) and 2 (NK2) formulas on a matched separate test set of 37 eyes of 19 patients. Results: The mean preoperative spherical equivalent was −5.32 ± 3.37 (range: +3.75 to −17.375 diopters). The mean absolute errors of the estimated vs achieved postoperative vault for the LASSO-Biometry, LASSO-OCT, and LASSO-Full formulas were 144.1 ± 107.9 μm, 145.6 ± 100.6 μm, and 132.0 ± 86.6 μm, respectively. These results were significantly lower compared with the OCOS, NK1, and NK2 formulas (P < .006). Postoperative vault could be estimated within 500 μm in 97.3% (LASSO-Biometry) to 100% of cases (LASSO-OCT and LASSO-Full). Conclusions: The LASSO suite provided a set of powerful, reproducible yet convenient ICL sizing formulas with state-of-the-art performance in White patients, including those with low to moderate degrees of myopia. The calculator can be accessed at http://icl.emmetropia.be.
- 14 October 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (2) , 126-132
Open AccessPostoperative vault prediction for phakic implantable collamer lens surgery: LASSO formulas
Purpose: To develop and evaluate reliable formulas for predicting postoperative vault more accurately after implantable collamer lens (ICL) surgery in a White patient population with varying degrees of ametropia. Setting: Private clinical practice. Design: Retrospective analysis on dataset split into a separate training and test set. Methods: 115 eyes of 59 patients were used to train regression models predicting postoperative vault based on anterior segment optical coherence tomography (OCT) parameters (Least Absolute Shrinkage and Selection Operator [LASSO]-OCT formula), ocular biometry data (LASSO-Biometry formula), or data from both devices (LASSO-Full formula). The performance of these models was evaluated against the manufacturer's nomogram (Online Calculation and Ordering System [OCOS]) and Nakamura 1 (NK1) and 2 (NK2) formulas on a matched separate test set of 37 eyes of 19 patients. Results: The mean preoperative spherical equivalent was −5.32 ± 3.37 (range: +3.75 to −17.375 diopters). The mean absolute errors of the estimated vs achieved postoperative vault for the LASSO-Biometry, LASSO-OCT, and LASSO-Full formulas were 144.1 ± 107.9 μm, 145.6 ± 100.6 μm, and 132.0 ± 86.6 μm, respectively. These results were significantly lower compared with the OCOS, NK1, and NK2 formulas (P < .006). Postoperative vault could be estimated within 500 μm in 97.3% (LASSO-Biometry) to 100% of cases (LASSO-OCT and LASSO-Full). Conclusions: The LASSO suite provided a set of powerful, reproducible yet convenient ICL sizing formulas with state-of-the-art performance in White patients, including those with low to moderate degrees of myopia. The calculator can be accessed at http://icl.emmetropia.be.
- Open Access
- 1 May 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 2117-2126
Bilateral Implantation of a New Refractive Multi-Segmented Multifocal Intraocular Lens in Cataract or Refractive Lens Exchange Patients
Purpose: To evaluate the safety and efficacy of a new multi-segmented refractive multifocal intraocular lens (IOL) after phacoemulsification and refractive lens exchange (RLE). Patients and Methods: In this prospective, multicenter clinical trial, 63 presbyopic subjects who had cataract or where RLE candidates were bilaterally implanted with the Precizon Presbyopia IOL (Ophtec BV, Groningen, the Netherlands) after phacoemulsification. The study was conducted at 6 clinical centers in Germany, the Netherlands, Belgium, Turkey and Spain. Subjects were evaluated at baseline and at 1 day, 1 week, 1 and 3 months postoperatively for monocular and binocular uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity (DCIVA), uncorrected (UNVA), corrected (CNVA) and distance-corrected near visual acuity (DCNVA), contrast sensitivity and quality of vision. Results: Three months postoperatively, binocular UDVA and CDVA of ≥ 20/40 was achieved in 98.4% (60/61) and 100%, respectively. Binocular UIVA and DCIVA of ≥ 20/40 was achieved in 96.7% (59/61) and 93.4% (57/61) respectively. Binocular UNVA, CNVA and DCNVA of ≥ 20/40 was achieved in 93.4% (57/61), 98.4% (60/61) and 95% (57/60) subjects, respectively. Complete spectacle independence was achieved in 80% (49/61) patients; 93% of patients reported that they were quite or very satisfied with the outcomes of the procedure. Conclusion: Precizon Presbyopia IOL implantation is a safe and effective method to provide good visual acuity at all distances in presbyopic and cataract patients.
- 1 May 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 2117-2126
Open AccessBilateral Implantation of a New Refractive Multi-Segmented Multifocal Intraocular Lens in Cataract or Refractive Lens Exchange Patients
Purpose: To evaluate the safety and efficacy of a new multi-segmented refractive multifocal intraocular lens (IOL) after phacoemulsification and refractive lens exchange (RLE). Patients and Methods: In this prospective, multicenter clinical trial, 63 presbyopic subjects who had cataract or where RLE candidates were bilaterally implanted with the Precizon Presbyopia IOL (Ophtec BV, Groningen, the Netherlands) after phacoemulsification. The study was conducted at 6 clinical centers in Germany, the Netherlands, Belgium, Turkey and Spain. Subjects were evaluated at baseline and at 1 day, 1 week, 1 and 3 months postoperatively for monocular and binocular uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity (DCIVA), uncorrected (UNVA), corrected (CNVA) and distance-corrected near visual acuity (DCNVA), contrast sensitivity and quality of vision. Results: Three months postoperatively, binocular UDVA and CDVA of ≥ 20/40 was achieved in 98.4% (60/61) and 100%, respectively. Binocular UIVA and DCIVA of ≥ 20/40 was achieved in 96.7% (59/61) and 93.4% (57/61) respectively. Binocular UNVA, CNVA and DCNVA of ≥ 20/40 was achieved in 93.4% (57/61), 98.4% (60/61) and 95% (57/60) subjects, respectively. Complete spectacle independence was achieved in 80% (49/61) patients; 93% of patients reported that they were quite or very satisfied with the outcomes of the procedure. Conclusion: Precizon Presbyopia IOL implantation is a safe and effective method to provide good visual acuity at all distances in presbyopic and cataract patients.
- Open Access
- 1 October 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3065-3066
Performance and Safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) in Phakic Subjects with Presbyopia [Corrigendum]
Performance and Safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) in Phakic Subjects with Presbyopia [Corrigendum]
- 1 October 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 3065-3066
Open AccessPerformance and Safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) in Phakic Subjects with Presbyopia [Corrigendum]
Performance and Safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) in Phakic Subjects with Presbyopia [Corrigendum]
- Open Access
- 1 September 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2717-2730
Performance and Safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) in Phakic Subjects with Presbyopia
Purpose: To evaluate the performance and safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) for improvement of uncorrected near, intermediate and distance visual acuity in phakic subjects with myopia and presbyopia. Design: Prospective multicenter study. Methods: Presbyopic subjects who required an EDOF ICL in the range of − 0.50 D to − 18.00 D, exhibited ≤ 0.75 D refractive astigmatism and required from +1.00 to +2.50 D reading add were implanted bilaterally. Assessments at 6 months included uncorrected near, intermediate and distance visual acuities, defocus curves, contrast sensitivity, responses to the National Eye Institute Refractive Error Quality of Life Questionnaire and a Task Assessment Questionnaire. Results: A total of 34 subjects completed the study. Investigators targeted emmetropia in all eyes. Mean binocular uncorrected near, intermediate and distance visual acuities measured logMAR − 0.01 ± 0.05 (20/20), − 0.02 ± 0.08 (20/19) and 0.07 ± 0.10 (20/23), respectively. Mean monocular uncorrected near, intermediate and distance visual acuities measured logMAR 0.068 ± 0.09 (20/23), 0.062 ± 0.10 (20/23) and 0.16 ± 0.12 (20/29). There were no clinically or statistically significant differences in contrast sensitivity between baseline and 6 months under any testing conditions. Subjects reported significant improvements in measures of vision-related quality of life and ability to perform tasks at all distances without glasses or contact lenses. Overall, satisfaction with the EDOF ICL was high: postoperatively, 91.2% of subjects were satisfied with their vision. Conclusion: This multicenter, prospective clinical investigation demonstrated the ability of the EDOF ICL to correct myopia and presbyopia, resulting in improvement of uncorrected near, intermediate and distance visual acuity without compromising the quality of vision. The EDOF ICL allowed subjects to perform tasks of daily living without glasses or contact lenses. Subjects reported significant improvements in quality of life with high levels of spectacle independence and satisfaction.
- 1 September 2020
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 14, 2717-2730
Open AccessPerformance and Safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) in Phakic Subjects with Presbyopia
Purpose: To evaluate the performance and safety of the Extended Depth of Focus Implantable Collamer® Lens (EDOF ICL) for improvement of uncorrected near, intermediate and distance visual acuity in phakic subjects with myopia and presbyopia. Design: Prospective multicenter study. Methods: Presbyopic subjects who required an EDOF ICL in the range of − 0.50 D to − 18.00 D, exhibited ≤ 0.75 D refractive astigmatism and required from +1.00 to +2.50 D reading add were implanted bilaterally. Assessments at 6 months included uncorrected near, intermediate and distance visual acuities, defocus curves, contrast sensitivity, responses to the National Eye Institute Refractive Error Quality of Life Questionnaire and a Task Assessment Questionnaire. Results: A total of 34 subjects completed the study. Investigators targeted emmetropia in all eyes. Mean binocular uncorrected near, intermediate and distance visual acuities measured logMAR − 0.01 ± 0.05 (20/20), − 0.02 ± 0.08 (20/19) and 0.07 ± 0.10 (20/23), respectively. Mean monocular uncorrected near, intermediate and distance visual acuities measured logMAR 0.068 ± 0.09 (20/23), 0.062 ± 0.10 (20/23) and 0.16 ± 0.12 (20/29). There were no clinically or statistically significant differences in contrast sensitivity between baseline and 6 months under any testing conditions. Subjects reported significant improvements in measures of vision-related quality of life and ability to perform tasks at all distances without glasses or contact lenses. Overall, satisfaction with the EDOF ICL was high: postoperatively, 91.2% of subjects were satisfied with their vision. Conclusion: This multicenter, prospective clinical investigation demonstrated the ability of the EDOF ICL to correct myopia and presbyopia, resulting in improvement of uncorrected near, intermediate and distance visual acuity without compromising the quality of vision. The EDOF ICL allowed subjects to perform tasks of daily living without glasses or contact lenses. Subjects reported significant improvements in quality of life with high levels of spectacle independence and satisfaction.
- Open Access
- 1 March 2011
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 5, 369-75
Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes
Peer reviewed article authored by (Erik L Mertens). Read article or submit your manuscript for publishing.
- 1 March 2011
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 5, 369-75
Open AccessToric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes
Peer reviewed article authored by (Erik L Mertens). Read article or submit your manuscript for publishing.