Comparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects
Open Access
- 4 February 2019
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Abstract
Despite the significant advantages that smartphones’ cameras can provide in teleophthalmology and artificial intelligence applications, their use as black-box systems for clinical data acquisition, without adequate information of the quality of photographs can compromise data accuracy. The aim of this study is to compare the objective and subjective quantification of conjunctival redness in images obtained with calibrated and non-calibrated cameras, in different lighting conditions and optical magnifications. One hundred ninety-two pictures of the eye were taken in 4 subjects using 3 smartphone cameras{Bq, Iphone, Nexus}, 2 lighting levels{high 815 lx, low 122 lx} and 2 magnification levels{high 10x, low 6x}. Images were duplicated: one set was white balanced and color corrected (calibrated) and the other was left as it was. Each image was subjective and objectively evaluated. There were no significant differences in subjective evaluation in any of the conditions whereas many statistically significant main effects and interaction effects were shown for all the objective metrics. The clinician’s evaluation was not affected by different cameras, lighting conditions or optical magnifications, demonstrating the effectiveness of the human eye’s color constancy properties. However, calibration of a smartphone’s camera is essential when extracting objective data from images.Keywords
Funding Information
- BEVISION EU Project.
This publication has 33 references indexed in Scilit:
- Automated grading system for evaluation of ocular redness associated with dry eyeClinical Ophthalmology, 2013
- Smartphones in ophthalmologyIndian Journal Of Ophthalmology, 2012
- Anterior segment slitlamp photography using the iPhoneJournal of Cataract & Refractive Surgery, 2010
- Telemedical diagnosis of anterior segment eye diseases: validation of digital slit-lamp still imagesEye, 2008
- Grading static versus dynamic images of contact lens complicationsClinical and Experimental Optometry, 2007
- How red is a white eye? Clinical grading of normal conjunctival hyperaemiaEye, 2006
- Incremental nature of anterior eye grading scales determined by objective image analysisBritish Journal of Ophthalmology, 2004
- The Red EyeNew England Journal of Medicine, 2000
- The Repeatability of Discrete and Continuous Anterior Segment Grading ScalesOptometry and Vision Science, 2000
- Objective Measurement of Contact Lens-Induced Conjunctival RednessOptometry and Vision Science, 1996