Carles Otero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carles Otero has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Jaume Pujol
Center for Sensors, Instruments and Systems Development, Universitat Politècnica de Catalunya, Terrassa, Spain
10 shared publicationsMikel Aldaba
Center for Sensors, Instruments and Systems Development, Universitat Politècnica de Catalunya, Terrassa, Spain
4 shared publications- Mikel Aldaba
Centre for Sensors, Instruments and Systems Development, Universitat Politecnica de Catalunya, Rambla Sant Nebridi 10, 08222 Terrassa, Spain
4 shared publications - Fernando Díaz-Doutón
Centre for Sensors, Instruments and Systems Development, Universitat Politecnica de Catalunya, Rambla Sant Nebridi 10, 08222 Terrassa, Spain
3 shared publications - Meritxell Vilaseca
Centre for Sensors, Instruments and Systems Development, Universitat Politècnica de Catalunya, 08222 Terrassa, Spain
3 shared publications Fuensanta A. Vera‐Diaz
New England College of Optometry, Boston, Massachusetts *
2 shared publications
Latest Publications
- Open Access
- 19 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Author Correction: Comparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 19 February 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1
Open AccessAuthor Correction: Comparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- Open Access
- 1 June 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (6) , 424-433
Stimulus Unpredictability in Time, Magnitude, and Direction on Accommodation
Supplemental digital content is available in the text. SIGNIFICANCE: The effect of predictability in changes of time, magnitude, and direction of the accommodation demand on the accommodation response latency and its magnitude are insignificant, which suggests that repetitive accommodative tasks such as the clinical accommodative facility test may not be influenced by potential anticipation effects. PURPOSE: The purpose of this study was to investigate the effect of stimulus' time, magnitude, and direction predictability, as well as their interactions, on accommodation latency and response magnitude. METHODS: Monocular accommodative response and latency were measured in 12 young subjects for nine different conditions where the stimulus accommodative demand changed several times in a steplike fashion for a period of 120 seconds. Each change in accommodative demand could have different time duration (i.e., 1, 2, or 3 seconds), magnitude (1, 2, or 3 diopters), and/or direction (i.e., accommodation or disaccommodation). All conditions were created permuting the factors of time, magnitude, and direction with two levels each: random and not random. The baseline condition was a step signal from 0 to 2 diopters persisting for 2 seconds in both accommodative demands. After each condition, subjects were asked to provide a score from 1 to 5 in their perceived predictability. RESULTS: Friedman test conducted on the perceived predictability of each condition resulted in statistically significant differences between the nine conditions (χ 2 = 56.57, P <. 01). However, repeated‐measures analysis of variance applied to latency and accommodative response magnitude did not show significant differences ( P >. 05). In addition, no correlation was found between the perceived predictability scores and both latency and accommodative response magnitudes between the most predictable and the most unpredictable conditions. CONCLUSIONS: Subjects were able to perceptually notice whether the stimulus was predictable or not, although our results indicate no significant effect of stimuli predictability on either the accommodation latency or its magnitude.
- 1 June 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (6) , 424-433
Open AccessStimulus Unpredictability in Time, Magnitude, and Direction on Accommodation
Supplemental digital content is available in the text. SIGNIFICANCE: The effect of predictability in changes of time, magnitude, and direction of the accommodation demand on the accommodation response latency and its magnitude are insignificant, which suggests that repetitive accommodative tasks such as the clinical accommodative facility test may not be influenced by potential anticipation effects. PURPOSE: The purpose of this study was to investigate the effect of stimulus' time, magnitude, and direction predictability, as well as their interactions, on accommodation latency and response magnitude. METHODS: Monocular accommodative response and latency were measured in 12 young subjects for nine different conditions where the stimulus accommodative demand changed several times in a steplike fashion for a period of 120 seconds. Each change in accommodative demand could have different time duration (i.e., 1, 2, or 3 seconds), magnitude (1, 2, or 3 diopters), and/or direction (i.e., accommodation or disaccommodation). All conditions were created permuting the factors of time, magnitude, and direction with two levels each: random and not random. The baseline condition was a step signal from 0 to 2 diopters persisting for 2 seconds in both accommodative demands. After each condition, subjects were asked to provide a score from 1 to 5 in their perceived predictability. RESULTS: Friedman test conducted on the perceived predictability of each condition resulted in statistically significant differences between the nine conditions (χ 2 = 56.57, P <. 01). However, repeated‐measures analysis of variance applied to latency and accommodative response magnitude did not show significant differences ( P >. 05). In addition, no correlation was found between the perceived predictability scores and both latency and accommodative response magnitudes between the most predictable and the most unpredictable conditions. CONCLUSIONS: Subjects were able to perceptually notice whether the stimulus was predictable or not, although our results indicate no significant effect of stimuli predictability on either the accommodation latency or its magnitude.
- Open Access
- 1 April 2019
- Published by Elsevier in Journal of Optometry
- Vol. 12 (2) , 74-83
Clinical evaluation of an automated subjective refraction method implemented in a computer-controlled motorized phoropter
- 1 April 2019
- Published by Elsevier in Journal of Optometry
- Vol. 12 (2) , 74-83
Open AccessClinical evaluation of an automated subjective refraction method implemented in a computer-controlled motorized phoropter
- Open Access
- 4 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Comparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects
Despite the significant advantages that smartphones’ cameras can provide in teleophthalmology and artificial intelligence applications, their use as black-box systems for clinical data acquisition, without adequate information of the quality of photographs can compromise data accuracy. The aim of this study is to compare the objective and subjective quantification of conjunctival redness in images obtained with calibrated and non-calibrated cameras, in different lighting conditions and optical magnifications. One hundred ninety-two pictures of the eye were taken in 4 subjects using 3 smartphone cameras{Bq, Iphone, Nexus}, 2 lighting levels{high 815 lx, low 122 lx} and 2 magnification levels{high 10x, low 6x}. Images were duplicated: one set was white balanced and color corrected (calibrated) and the other was left as it was. Each image was subjective and objectively evaluated. There were no significant differences in subjective evaluation in any of the conditions whereas many statistically significant main effects and interaction effects were shown for all the objective metrics. The clinician’s evaluation was not affected by different cameras, lighting conditions or optical magnifications, demonstrating the effectiveness of the human eye’s color constancy properties. However, calibration of a smartphone’s camera is essential when extracting objective data from images.
- 4 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Open AccessComparison of different smartphone cameras to evaluate conjunctival hyperaemia in normal subjects
Despite the significant advantages that smartphones’ cameras can provide in teleophthalmology and artificial intelligence applications, their use as black-box systems for clinical data acquisition, without adequate information of the quality of photographs can compromise data accuracy. The aim of this study is to compare the objective and subjective quantification of conjunctival redness in images obtained with calibrated and non-calibrated cameras, in different lighting conditions and optical magnifications. One hundred ninety-two pictures of the eye were taken in 4 subjects using 3 smartphone cameras{Bq, Iphone, Nexus}, 2 lighting levels{high 815 lx, low 122 lx} and 2 magnification levels{high 10x, low 6x}. Images were duplicated: one set was white balanced and color corrected (calibrated) and the other was left as it was. Each image was subjective and objectively evaluated. There were no significant differences in subjective evaluation in any of the conditions whereas many statistically significant main effects and interaction effects were shown for all the objective metrics. The clinician’s evaluation was not affected by different cameras, lighting conditions or optical magnifications, demonstrating the effectiveness of the human eye’s color constancy properties. However, calibration of a smartphone’s camera is essential when extracting objective data from images.
- Open Access
- 1 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0206674
An automated and objective cover test to measure heterophoria
Heterophoria is the relative deviation of the eyes in absence of fusional vergence. Fusional vergence can be deprived by, for example, occluding one eye while the other fixates a visual target. Then, the occluded eye will presumably deviate from its initial position by an amount that corresponds to the heterophoria. Its assessment in clinical practice is crucial for the diagnosis of non-strabismic binocular dysfunctions such as convergence insufficiency. Traditional clinical methods, like the cover test or the modified Thorington test, suffer from practitioner’s subjectivity, impossibility to observe the occluding eye or unusual viewing conditions. These limitations could be overcome by using eye tracking systems to measure objectively the heterophoria. The main purpose of this study was to compare the performance of an automated and objective method to measure near heterophoria using an eye-tracker with two conventional methods: the cover-uncover test and the modified Thorington test. The eye tracking method gave us the possibility to measure the heterophoria as the deviation of the occluded eye (mimicking the cover test) or as the deviations of the occluded and fixating eyes (adhering to the theoretical definition of heterophoria). The latter method provided smaller results than the former, although on average the differences might not be clinically relevant. The proposed objective method exhibited considerably better repeatability than the two conventional clinical methods. It showed better agreement with the modified Thorington test than with the cover-uncover test, and a similar level of agreement was obtained between the two clinical methods. To conclude, the use of eye-trackers to measure heterophoria provides objective and more repeatable measures. As eye-trackers become common tools in clinical settings, their use to measure heterophoria should be the new gold standard.
- 1 November 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (11) , e0206674
Open AccessAn automated and objective cover test to measure heterophoria
Heterophoria is the relative deviation of the eyes in absence of fusional vergence. Fusional vergence can be deprived by, for example, occluding one eye while the other fixates a visual target. Then, the occluded eye will presumably deviate from its initial position by an amount that corresponds to the heterophoria. Its assessment in clinical practice is crucial for the diagnosis of non-strabismic binocular dysfunctions such as convergence insufficiency. Traditional clinical methods, like the cover test or the modified Thorington test, suffer from practitioner’s subjectivity, impossibility to observe the occluding eye or unusual viewing conditions. These limitations could be overcome by using eye tracking systems to measure objectively the heterophoria. The main purpose of this study was to compare the performance of an automated and objective method to measure near heterophoria using an eye-tracker with two conventional methods: the cover-uncover test and the modified Thorington test. The eye tracking method gave us the possibility to measure the heterophoria as the deviation of the occluded eye (mimicking the cover test) or as the deviations of the occluded and fixating eyes (adhering to the theoretical definition of heterophoria). The latter method provided smaller results than the former, although on average the differences might not be clinically relevant. The proposed objective method exhibited considerably better repeatability than the two conventional clinical methods. It showed better agreement with the modified Thorington test than with the cover-uncover test, and a similar level of agreement was obtained between the two clinical methods. To conclude, the use of eye-trackers to measure heterophoria provides objective and more repeatable measures. As eye-trackers become common tools in clinical settings, their use to measure heterophoria should be the new gold standard.
- Open Access
- 28 February 2018
- Published by Taylor & Francis in Current Eye Research
- Vol. 43 (6) , 788-795
Random Changes of Accommodation Stimuli: An Automated Extension of the Flippers Accommodative Facility Test
To study the accommodative dynamics for predictable and unpredictable stimuli using manual and automated accommodative facility tests Materials and Methods: Seventeen young healthy subjects were tested monocularly in two consecutive sessions, using five different conditions. Two conditions replicated the conventional monocular accommodative facility tests for far and near distances, performed with manually held flippers. The other three conditions were automated and conducted using an electro-optical system and open-field autorefractor. Two of the three automated conditions replicated the predictable manual accommodative facility tests. The last automated condition was a hybrid approach using a novel method whereby far and near-accommodative-facility tests were randomly integrated into a single test of four unpredictable accommodative demands. The within-subject standard deviations for far- and near-distance-accommodative reversals were (±1,±1) cycles per minute (cpm) for the manual flipper accommodative facility conditions and (±3, ±4) cpm for the automated conditions. The 95% limits of agreement between the manual and the automated conditions for far and near distances were poor: (-18, 12) and (-15, 3). During the hybrid unpredictable condition, the response time and accommodative response parameters were significantly (p < 0.05) larger for accommodation than disaccommodation responses for high accommodative demands only. The response times during the transitions 0.17/2.17 D and 0.50/4.50 D appeared to be indistinguishable between the hybrid unpredictable and the conventional predictable automated tests. The automated accommodative facility test does not agree with the manual flipper test results. Operator delays in flipping the lens may account for these differences. This novel test, using unpredictable stimuli, provides a more comprehensive examination of accommodative dynamics than conventional manual accommodative facility tests. Unexpectedly, the unpredictability of the stimulus did not to affect accommodation dynamics. Further studies are needed to evaluate the sensitivity of this novel hybrid technique on individuals with accommodative anomalies.
- 28 February 2018
- Published by Taylor & Francis in Current Eye Research
- Vol. 43 (6) , 788-795
Open AccessRandom Changes of Accommodation Stimuli: An Automated Extension of the Flippers Accommodative Facility Test
To study the accommodative dynamics for predictable and unpredictable stimuli using manual and automated accommodative facility tests Materials and Methods: Seventeen young healthy subjects were tested monocularly in two consecutive sessions, using five different conditions. Two conditions replicated the conventional monocular accommodative facility tests for far and near distances, performed with manually held flippers. The other three conditions were automated and conducted using an electro-optical system and open-field autorefractor. Two of the three automated conditions replicated the predictable manual accommodative facility tests. The last automated condition was a hybrid approach using a novel method whereby far and near-accommodative-facility tests were randomly integrated into a single test of four unpredictable accommodative demands. The within-subject standard deviations for far- and near-distance-accommodative reversals were (±1,±1) cycles per minute (cpm) for the manual flipper accommodative facility conditions and (±3, ±4) cpm for the automated conditions. The 95% limits of agreement between the manual and the automated conditions for far and near distances were poor: (-18, 12) and (-15, 3). During the hybrid unpredictable condition, the response time and accommodative response parameters were significantly (p < 0.05) larger for accommodation than disaccommodation responses for high accommodative demands only. The response times during the transitions 0.17/2.17 D and 0.50/4.50 D appeared to be indistinguishable between the hybrid unpredictable and the conventional predictable automated tests. The automated accommodative facility test does not agree with the manual flipper test results. Operator delays in flipping the lens may account for these differences. This novel test, using unpredictable stimuli, provides a more comprehensive examination of accommodative dynamics than conventional manual accommodative facility tests. Unexpectedly, the unpredictability of the stimulus did not to affect accommodation dynamics. Further studies are needed to evaluate the sensitivity of this novel hybrid technique on individuals with accommodative anomalies.
- Open Access
- 1 December 2017
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (12) , 1120-1128
Effect of Experimental Conditions in the Accommodation Response in Myopia
SIGNIFICANCE: The accommodative response is more affected by the type of refractive error than the method of stimulation, field of view (FOV), or stimulus depth. PURPOSE: This study aims to analyze the effect of stimulation method, stimulus depth, and FOV on the accommodation response (AR) for emmetropes (EMM), late‐onset myopes (LOM), and early‐onset myopes (EOM). METHODS: Monocular AR was measured in 26 young observers (n = 9 EMM, n = 8 LOM, n = 9 EOM) under 60 different viewing conditions that were the result of permuting the following factors: (1) stimulation method (free space or Badal lens viewing), (2) stimulus depth (flat or volumetric), (3) FOV (2.5, 4, 8, 10, and 30°), and (4) accommodative stimulus (AS: 0.17, 2.50, and 5.00 diopters [D]). RESULTS: Mixed analysis of variance for 2.50 D of AS resulted in a significant effect of refractive group (F = 6.77, P <. 01) and FOV (F = 1.26, P =. 04). There was also a significant interaction between stimulus depth and FOV (F = 2.73, P =. 03) and among stimulation method, FOV, and refractive group (F = 2.42, P =. 02). For AS of 5.00 D, there was a significant effect of refractive group (F = 13.88, P <. 01) and stimulation method (F = 5.16, P =. 03). There was also a significant interaction of stimulation method, stimulus depth, and refractive group (F = 4.08, P =. 03). When controlling for all interactions, LOM showed larger lags than EMM and EOM; the AR did not significantly change for fields of 8, 10, and 30°, and it did not significantly differ for different stimulation methods or stimulus depth. CONCLUSIONS: Previously reported differences in AR when using lens‐based methods compared with free space viewing may be explained by the effect of other factors such as the FOV or the depth of the stimulus. Targets with an FOV of 8 or 10° may be optimal for accurate ARs.
- 1 December 2017
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (12) , 1120-1128
Open AccessEffect of Experimental Conditions in the Accommodation Response in Myopia
SIGNIFICANCE: The accommodative response is more affected by the type of refractive error than the method of stimulation, field of view (FOV), or stimulus depth. PURPOSE: This study aims to analyze the effect of stimulation method, stimulus depth, and FOV on the accommodation response (AR) for emmetropes (EMM), late‐onset myopes (LOM), and early‐onset myopes (EOM). METHODS: Monocular AR was measured in 26 young observers (n = 9 EMM, n = 8 LOM, n = 9 EOM) under 60 different viewing conditions that were the result of permuting the following factors: (1) stimulation method (free space or Badal lens viewing), (2) stimulus depth (flat or volumetric), (3) FOV (2.5, 4, 8, 10, and 30°), and (4) accommodative stimulus (AS: 0.17, 2.50, and 5.00 diopters [D]). RESULTS: Mixed analysis of variance for 2.50 D of AS resulted in a significant effect of refractive group (F = 6.77, P <. 01) and FOV (F = 1.26, P =. 04). There was also a significant interaction between stimulus depth and FOV (F = 2.73, P =. 03) and among stimulation method, FOV, and refractive group (F = 2.42, P =. 02). For AS of 5.00 D, there was a significant effect of refractive group (F = 13.88, P <. 01) and stimulation method (F = 5.16, P =. 03). There was also a significant interaction of stimulation method, stimulus depth, and refractive group (F = 4.08, P =. 03). When controlling for all interactions, LOM showed larger lags than EMM and EOM; the AR did not significantly change for fields of 8, 10, and 30°, and it did not significantly differ for different stimulation methods or stimulus depth. CONCLUSIONS: Previously reported differences in AR when using lens‐based methods compared with free space viewing may be explained by the effect of other factors such as the FOV or the depth of the stimulus. Targets with an FOV of 8 or 10° may be optimal for accurate ARs.
- Open Access
- 1 November 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (6) , 649-655
Effect of apparent depth cues on accommodation in a Badal optometer
The aim was to analyse the effect of peripheral depth cues on accommodation in Badal optometers.Monocular refractions at 0.17 and 5.00 D of accommodative stimulus were measured with the PowerRef II...
- 1 November 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (6) , 649-655
Open AccessEffect of apparent depth cues on accommodation in a Badal optometer
The aim was to analyse the effect of peripheral depth cues on accommodation in Badal optometers.Monocular refractions at 0.17 and 5.00 D of accommodative stimulus were measured with the PowerRef II...
- Open Access
- 18 April 2017
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 10 (4) , 567-572
Suitability of open-field autorefractors as pupillometers and instrument design effects
To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics), PowerRef II (Plusoptix), WAM-5500 (Grand Seiko) and study the effects of instrument design on pupillometry. Forty patients were measured twice in low, mid and high mesopic. Repeatability was analyzed with the within-subject standard deviation (Sw) and paired t-tests. Agreement was studied with Bland-Altman plots and repeated measures ANOVA. Instrument design analysis consisted on measuring pupil size with PowerRef II simulating monocular and binocular conditions as well as with proximity cues and without proximity cues. The mean difference (±standard deviation) between test-retest for low, mid and high mesopic conditions were, respectively: -0.09 (±0.16), -0.05 (±0.18) and -0.08 (±0.23) mm for Neuroptics, -0.05 (±0.17), -0.12 (±0.23) and -0.17 (±0.34) mm for WAM-5500, -0.04 (±0.27), -0.13 (±0.37) and -0.11 (±0.28) mm for PowerRef II. Regarding agreement with Neuroptics, the mean difference for low, mid and high mesopic conditions were, respectively: -0.48 (±0.35), -0.83 (±0.52) and -0.38 (±0.56) mm for WAM-5500, -0.28 (±0.56), -0.70 (±0.55) and -0.61 (±0.54) mm for PowerRef II. The mean difference of binocular minus monocular pupil measurements was: -0.83 (±0.87) mm; and with proximity cues minus without proximity cues was: -0.30 (±0.77) mm. All the instruments show similar repeat-ability. In all illumination conditions, agreement of Neuroptics with WAM-5500 and PowerRef II is not good enough, which can be partially induced due to their open field design.
- 18 April 2017
- Published by Press of International Journal of Ophthalmology (IJO Press) in International Journal of Ophthalmology
- Vol. 10 (4) , 567-572
Open AccessSuitability of open-field autorefractors as pupillometers and instrument design effects
To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics), PowerRef II (Plusoptix), WAM-5500 (Grand Seiko) and study the effects of instrument design on pupillometry. Forty patients were measured twice in low, mid and high mesopic. Repeatability was analyzed with the within-subject standard deviation (Sw) and paired t-tests. Agreement was studied with Bland-Altman plots and repeated measures ANOVA. Instrument design analysis consisted on measuring pupil size with PowerRef II simulating monocular and binocular conditions as well as with proximity cues and without proximity cues. The mean difference (±standard deviation) between test-retest for low, mid and high mesopic conditions were, respectively: -0.09 (±0.16), -0.05 (±0.18) and -0.08 (±0.23) mm for Neuroptics, -0.05 (±0.17), -0.12 (±0.23) and -0.17 (±0.34) mm for WAM-5500, -0.04 (±0.27), -0.13 (±0.37) and -0.11 (±0.28) mm for PowerRef II. Regarding agreement with Neuroptics, the mean difference for low, mid and high mesopic conditions were, respectively: -0.48 (±0.35), -0.83 (±0.52) and -0.38 (±0.56) mm for WAM-5500, -0.28 (±0.56), -0.70 (±0.55) and -0.61 (±0.54) mm for PowerRef II. The mean difference of binocular minus monocular pupil measurements was: -0.83 (±0.87) mm; and with proximity cues minus without proximity cues was: -0.30 (±0.77) mm. All the instruments show similar repeat-ability. In all illumination conditions, agreement of Neuroptics with WAM-5500 and PowerRef II is not good enough, which can be partially induced due to their open field design.
- Open Access
- 1 January 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (1) , 26-32
Comparison of the Adaptive Optics Vision Analyzer and the KR‐1 W for measuring ocular wave aberrations
The aim was to assess the agreement in the measurement of ocular aberrations between a new Adaptive Optics Vision Analyzer (AOVA, Voptica, Murcia, Spain) and a commercial aberrometer (KR‐1 W, Topco...
- 1 January 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (1) , 26-32
Open AccessComparison of the Adaptive Optics Vision Analyzer and the KR‐1 W for measuring ocular wave aberrations
The aim was to assess the agreement in the measurement of ocular aberrations between a new Adaptive Optics Vision Analyzer (AOVA, Voptica, Murcia, Spain) and a commercial aberrometer (KR‐1 W, Topco...