Comparison of Freelite and N-Latex serum free light chain assays
Authors:
Open Access
- 15 October 2021
- journal article
- review article
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 31 (3) , 431-438
Abstract
The measurement of serum free light chain (FLC) represents a fundamental aspect on the assessment of patients with monoclonal gammopathies (MG). Different analytical methods for FLC have become available with the possibility to obtain different value with a substantial impact on the assessment of patients with MG. This study aimed to evaluate FLC results obtained with two different assays and how the difference value obtained can impact in the patient’s assessment. Ninety-three patient serum samples that underwent analysis for FLC with two different methods, Serum Freelite (The Binding Site, Birmingham, UK) and N-Latex FLC (Siemens, Marburg, Germany), were included in this retrospective study. Statistical analysis was performed to evaluate correlation, difference, and the grade of concordance between the results obtained with the two methods. Significant statistical differences between the results obtained from the two methods were found (P < 0.05). A good correlation was found (0.99 for κ FLC, 0.95 for λ FLC, and 0.94 for the κ/λ ratio, respectively). We found a weighted kappa value of 0.65 for κ/λ ratio, 0.65 for λ FLC and 0.90 for κ FLC. A positive bias found with the Bland-Altman plot mirrors overestimation of κ FLC and κ/λ ratio with Freelite compared to N-Latex, whilst a negative bias underscores underestimation of λ FLC by Freelite compared to N-Latex. Although in general the concordance between Freelite and N-Latex appears satisfactory, several discrepancies could be evidenced and consequently the two assays are not interchangeable.Keywords
This publication has 24 references indexed in Scilit:
- Measurement of free light chains with assays based on monoclonal antibodiesClinical Chemistry and Laboratory Medicine (CCLM), 2016
- Measurement of free light chains – pros and cons of current methodsClinical Chemistry and Laboratory Medicine (CCLM), 2016
- International Myeloma Working Group updated criteria for the diagnosis of multiple myelomaThe Lancet Oncology, 2014
- Serum free light chain analysis in the diagnosis and management of multiple myeloma and related conditionsExpert Review of Molecular Diagnostics, 2013
- Effect of sample dilution on two free light chain nephelometric assaysClinica Chimica Acta, 2012
- N Latex FLC – new monoclonal high-performance assays for the determination of free light chain kappa and lambdaClinical Chemistry and Laboratory Medicine (CCLM), 2011
- Serum immunoglobulin free light-chain measurement in primary amyloidosis: prognostic value and correlations with clinical featuresBlood, 2010
- Overestimation of Serum κ Free Light Chain Concentration by ImmunonephelometryClinical Chemistry, 2010
- International Myeloma Working Group guidelines for serum-free light chain analysis in multiple myeloma and related disordersLeukemia, 2008
- Quantitative Assessment of Serum and Urinary Polyclonal Free Light Chains in Patients with Chronic Kidney DiseaseClinical Journal of the American Society of Nephrology, 2008