Potential risk factors of atrial fibrillation recurrence after cryoballoon ablation
- 30 June 2022
- journal article
- research article
- Published by APO Society of Specialists in Heart Failure in Kardiologiia
- Vol. 62 (6) , 23-29
Abstract
Aim To identify risk factors for recurrence of atrial fibrillation (AF) following cryoballoon ablation (CBA). Material and methods This prospective study included patients with paroxysmal AF who had undergone CBA (141 patients, median age 60 years, 3% men). The evaluation prior to CBA included clinical instrumental parameters (electrocardiography (ECG), 24-h ECG monitoring, echocardiography, contrast-enhanced cardiac multispiral computed tomography). Also, possible intraoperative indexes that could affect the CBA effectivity, were evaluated. The postoperative follow-up duration was 12 months. Effectivity was assessed during in-person visits at 3, 6, and 12 months, when questioning of patients and 24-h ECG monitoring were performed. CBA was considered ineffective if the patient had recurrences of any atrial tachyarrhythmia longer than 30 sec after the end of the 3-month “blind” period. Results During the 12-month follow-up, recurrences of atrial tachyarrhythmia were observed in 46 (32.6 %) patients. Patients with ineffective CBA more frequently had AF during the first 3 months (71.7 % vs. 11.6 %; рvs . 20.0 %; р=0.008), and stroke/recurrent ischemic attacks (15.2 % vs . 5.2 %; р=0.047). Multifactorial regression analysis showed that the factors of AF recurrence included common PV collector (relative risk (RR) 2.35; 95 % confidence interval (CI) 1.29–4.25; р=0.005), multiple ineffective AADs (RR 1.42; 95 % CI 1.08–1.86; р=0.011), and early AF recurrence (RR 7.57; 95 % CI 3.84–14.90; рConclusion Common PV collector and multiple ineffective AADs are risk factors of ineffective CBA. Early recurrences during the first 3 postoperative months are a significant risk factor of long-term AF recurrences.Keywords
This publication has 29 references indexed in Scilit:
- Predictors of late atrial fibrillation recurrence after cryoballoon-based pulmonary vein isolation: a meta-analysisPolish Heart Journal, 2017
- Predicting atrial fibrillation ablation outcome: The CAAP-AF scoreHeart Rhythm, 2016
- Cryoballoon or radiofrequency ablation for symptomatic paroxysmal atrial fibrillation: reintervention, rehospitalization, and quality-of-life outcomes in the FIRE AND ICE trialEuropean Heart Journal, 2016
- One-year follow-up after second-generation cryoballoon ablation for atrial fibrillation in a large cohort of patients: a single-centre experienceEP Europace, 2015
- Evaluating the Atrial Myopathy Underlying Atrial FibrillationCirculation, 2015
- Fibrotic Atrial Cardiomyopathy, Atrial Fibrillation, and ThromboembolismJACC, 2015
- The APPLE score: a novel and simple score for the prediction of rhythm outcomes after catheter ablation of atrial fibrillationClinical Research in Cardiology, 2015
- Refralon (niferidil) is a new class III antiarrhythmic agent for pharmacological cardioversion for persistent atrial fibrillation and atrial flutterTerapevticheskii arkhiv, 2015
- Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoonHeart Rhythm, 2015
- Pulmonary vein isolation: The impact of pulmonary venous anatomy on long-term outcome of catheter ablation for paroxysmal atrial fibrillationHeart Rhythm, 2014