I. A. Novikov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
I. A. Novikov has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Peter Sergeevich Novikov
National Medical Research Center of Cardiology
4 shared publications - Evgeny Borisovich Maykov
E.I. Chazov National Medical Research Centre of Cardiology
3 shared publications - Mustafa Gabarin
Cardiology Department, Meir Medical Center, Kfar Saba 4428164, Israel
3 shared publications - Nikolay Yu. Mironov
E.I. Chazov National Medical Research Center Of Cardiology
3 shared publications - Abid Assali
Cardiology Department, Meir Medical Center, Tel Aviv University, Tel Aviv-Yafo 6997801, Israel
2 shared publications - David Pereg
Cardiology department, Meir Medical Center, kfar Saba, Israel
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (30)
ST-Segment Elevation Caused by Lung Cancer Mimicking STEMI
- 29 July 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (30)
Open AccessST-Segment Elevation Caused by Lung Cancer Mimicking STEMI
- Open Access
- 2 August 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (15) , 5449
A TAVI Programme Without an On-Site Cardiac Surgery Department: A Single-Center Retrospective Study
Background: Aortic stenosis (AS) is the most common valvular heart disease, associated with poor outcomes if left untreated. Current guidelines recommend that transcatheter aortic valve implantation (TAVI) procedures be performed in hospitals with an on-site cardiac surgery unit due to potential complications requiring surgical intervention. Objective: Based on our experience, we evaluated the feasibility and outcomes of implementing a TAVI program in a cardiology department without an on-site cardiac surgery unit, in collaboration with a remote hospital for surgical backup. Methods: The TAVI program involved pre- and post-procedural evaluations conducted at Meir Medical Center (Kfar Saba, Israel) with a remote surgical team available. The study population included 149 consecutive patients with severe aortic stenosis treated at the Meir valve clinic between November 2019 and December 2023. Procedures were performed by the center’s interventional cardiology team. Results: The mean age of the 149 patients was 80 ± 6 years, and 75 (50%) were female. The average STS score was 4.3, and the EuroSCORE II was 3.1. Among the patients, 68 (45%) were classified as New York Heart Association (NYHA) class III-IV. The valve types used included ACURATE neo2 (57 patients, 38%), Edwards SAPIEN 3 (43 patients, 28%), Evolut-PRO (41 patients, 27%), and Navitor (7 patients, 4%). There were no cases of moderate to severe paravalvular leak and no elevated post-implantation gradients, and there was no need for urgent cardiac surgery. One case of valve embolization was successfully managed percutaneously during the procedure. In-hospital follow-up revealed no deaths and only one major vascular complication. At one-year follow-up, six patients had died, with only one death attributed to cardiac causes. Conclusions: Our findings support the safe and effective performance of transfemoral TAVI in cardiology departments without on-site cardiac surgery, in collaboration with a remote surgical team. Further prospective, multicenter studies are warranted to confirm these results and guide broader clinical implementation of this practice.
- 2 August 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (15) , 5449
Open AccessA TAVI Programme Without an On-Site Cardiac Surgery Department: A Single-Center Retrospective Study
Background: Aortic stenosis (AS) is the most common valvular heart disease, associated with poor outcomes if left untreated. Current guidelines recommend that transcatheter aortic valve implantation (TAVI) procedures be performed in hospitals with an on-site cardiac surgery unit due to potential complications requiring surgical intervention. Objective: Based on our experience, we evaluated the feasibility and outcomes of implementing a TAVI program in a cardiology department without an on-site cardiac surgery unit, in collaboration with a remote hospital for surgical backup. Methods: The TAVI program involved pre- and post-procedural evaluations conducted at Meir Medical Center (Kfar Saba, Israel) with a remote surgical team available. The study population included 149 consecutive patients with severe aortic stenosis treated at the Meir valve clinic between November 2019 and December 2023. Procedures were performed by the center’s interventional cardiology team. Results: The mean age of the 149 patients was 80 ± 6 years, and 75 (50%) were female. The average STS score was 4.3, and the EuroSCORE II was 3.1. Among the patients, 68 (45%) were classified as New York Heart Association (NYHA) class III-IV. The valve types used included ACURATE neo2 (57 patients, 38%), Edwards SAPIEN 3 (43 patients, 28%), Evolut-PRO (41 patients, 27%), and Navitor (7 patients, 4%). There were no cases of moderate to severe paravalvular leak and no elevated post-implantation gradients, and there was no need for urgent cardiac surgery. One case of valve embolization was successfully managed percutaneously during the procedure. In-hospital follow-up revealed no deaths and only one major vascular complication. At one-year follow-up, six patients had died, with only one death attributed to cardiac causes. Conclusions: Our findings support the safe and effective performance of transfemoral TAVI in cardiology departments without on-site cardiac surgery, in collaboration with a remote surgical team. Further prospective, multicenter studies are warranted to confirm these results and guide broader clinical implementation of this practice.
- Open Access
- 21 April 2025
- Published by MDPI AG in Preprints.org
TAVI Program in a Center Without On-Site Cardiac Surgical Department
Background: Aortic stenosis (AS) is the most common valvular heart disease, associated with poor outcomes if left untreated. Current guidelines recommend that transcatheter aortic valve implantation (TAVI) procedures be performed in hospitals with an on-site cardiac surgery unit due to potential complications requiring surgical intervention. This study aims to evaluate the feasibility and clinical outcomes of implementing a TAVI program at a cardiology department without an on-site cardiac surgery department, in collaboration with a remote hospital for surgical backup. Methods: The TAVI program involved pre- and post-procedural evaluations conducted at Meir Medical Center (Kfar Saba, Israel) with a remote surgical team available. The study population included 149 consecutive patients with severe aortic stenosis treated at the Meir valve clinic between November 2019 and December 2023. Procedures were performed by the center's interventional cardiology team. Results: The mean age of the 149 patients was 80 ± 6 years, and 75 (50%) were female. The average STS score was 4.3 and the EuroSCORE II was 3.1. Among the patients, 68 (45%) were classified as New York Heart Association (NYHA) class III-IV. Valve types used included Acurate-neo 2 (57 patients, 38%), Sapien-3 (43 patients, 28%), Evolut-PRO (41 patients, 27%), and Navitor (7 patients, 4%). There were no cases of moderate to severe paravalvular leak, no elevated post-implantation gradients, and no need for urgent cardiac surgery. One case of valve embolization was successfully managed percutaneously during the procedure. In-hospital follow-up revealed no deaths and only one major vascular complication. At one-year follow-up, six patients had died, with only one death attributed to cardiac causes. Conclusions: This study demonstrates that the transfemoral TAVI procedure can be safely and effectively performed in a cardiology department without an on-site cardiac surgery unit, provided there is collaboration with a remote surgical center. These findings suggest that expanding TAVI programs to centers without on-site cardiac surgery could increase access to this life-saving treatment for aortic stenosis.
- 21 April 2025
- Published by MDPI AG in Preprints.org
Open AccessTAVI Program in a Center Without On-Site Cardiac Surgical Department
Background: Aortic stenosis (AS) is the most common valvular heart disease, associated with poor outcomes if left untreated. Current guidelines recommend that transcatheter aortic valve implantation (TAVI) procedures be performed in hospitals with an on-site cardiac surgery unit due to potential complications requiring surgical intervention. This study aims to evaluate the feasibility and clinical outcomes of implementing a TAVI program at a cardiology department without an on-site cardiac surgery department, in collaboration with a remote hospital for surgical backup. Methods: The TAVI program involved pre- and post-procedural evaluations conducted at Meir Medical Center (Kfar Saba, Israel) with a remote surgical team available. The study population included 149 consecutive patients with severe aortic stenosis treated at the Meir valve clinic between November 2019 and December 2023. Procedures were performed by the center's interventional cardiology team. Results: The mean age of the 149 patients was 80 ± 6 years, and 75 (50%) were female. The average STS score was 4.3 and the EuroSCORE II was 3.1. Among the patients, 68 (45%) were classified as New York Heart Association (NYHA) class III-IV. Valve types used included Acurate-neo 2 (57 patients, 38%), Sapien-3 (43 patients, 28%), Evolut-PRO (41 patients, 27%), and Navitor (7 patients, 4%). There were no cases of moderate to severe paravalvular leak, no elevated post-implantation gradients, and no need for urgent cardiac surgery. One case of valve embolization was successfully managed percutaneously during the procedure. In-hospital follow-up revealed no deaths and only one major vascular complication. At one-year follow-up, six patients had died, with only one death attributed to cardiac causes. Conclusions: This study demonstrates that the transfemoral TAVI procedure can be safely and effectively performed in a cardiology department without an on-site cardiac surgery unit, provided there is collaboration with a remote surgical center. These findings suggest that expanding TAVI programs to centers without on-site cardiac surgery could increase access to this life-saving treatment for aortic stenosis.
- Open Access
- 20 July 2023
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 30 (3) , 40-48
Efficacy of different variants of endocardial balloon cryoablation in patients with persistent atrial fibrillation
Aim. To study the effectiveness of “extended” cryoballon ablation in patients with a persistent form of atrial fibrillation (AF) and to determine the risk factors for AF recurrence after cryoablation.Methods. The study included 89 patients (62±10 years, 24 [27%] men) with a persistent form of AF. The patients were randomized into two groups: in the 1st, the pulmonary veins (PV) cryoablation was performed (n=48 [53.9%]); in the 2nd, the PV cryoablation was performed in combination with cryoablation of the posterior wall of the left atrium (n=41 [46.1%]). The number of patients at high risk of thromboembolic events predominated in Group 2 (p=0,03). There is a high frequency of taking antiarrhythmic drugs of class III in this group (p=0.018). The follow-up period was 12 months. Clinical efficacy was assessed during a survey and daily ECG monitoring at face-to-face visits after 3, 6 and 12 months.Results. Antral isolation of PV was achieved in all 89 (100%) patients in both groups. In group 2, the average number of applications in the posterior wall of the PV was 10 [9; 13]. The effectiveness of cryoablation in group 1 by the end of the 12-month follow-up period was 54.2%, in group 2 - 56.1%. The complication rate (6.7%) in both groups did not differ statistically (p=0.683). The risk of arrhythmia recurrence didn’t depend on the strategy of cryoablation in postablation period (p=0.834). When conducting a single-factor analysis, a statistically significant effect on the probability of AF recurrence in the period of 3-12 months in group 1 was caused by AF recurrence in the blind period (95% confidence interval (CI): 1.5-27.7, p=0.013), in group 2 belonging to the female sex (95% CI: 1.2-24.6, p=0.032) and AF relapse in the blind period (95% CI: 1.5-128.5, p=0.020). During multivariate analysis in group 2, a statistically significant influence on the risk of AF recurrence in the period of 3-12 months was exerted by belonging to the female sex (hazard ratio (HR) 7.84; 95% CI 1478-42,23; p=0.016) and the presence of early AF recurrence (HR 20.36; 95% CI 1.99-208.23; p=0.011).Conclusion. Extended cryoablation in terms of efficiency and safety was comparable with the standard cryoablation. Early recurrence of AF (in the first 3 months after the intervention) turned out to be an independent risk factor for AF recurrence in the long-term period up to 12 months after cryoablation in both groups.
- 20 July 2023
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 30 (3) , 40-48
Open AccessEfficacy of different variants of endocardial balloon cryoablation in patients with persistent atrial fibrillation
Aim. To study the effectiveness of “extended” cryoballon ablation in patients with a persistent form of atrial fibrillation (AF) and to determine the risk factors for AF recurrence after cryoablation.Methods. The study included 89 patients (62±10 years, 24 [27%] men) with a persistent form of AF. The patients were randomized into two groups: in the 1st, the pulmonary veins (PV) cryoablation was performed (n=48 [53.9%]); in the 2nd, the PV cryoablation was performed in combination with cryoablation of the posterior wall of the left atrium (n=41 [46.1%]). The number of patients at high risk of thromboembolic events predominated in Group 2 (p=0,03). There is a high frequency of taking antiarrhythmic drugs of class III in this group (p=0.018). The follow-up period was 12 months. Clinical efficacy was assessed during a survey and daily ECG monitoring at face-to-face visits after 3, 6 and 12 months.Results. Antral isolation of PV was achieved in all 89 (100%) patients in both groups. In group 2, the average number of applications in the posterior wall of the PV was 10 [9; 13]. The effectiveness of cryoablation in group 1 by the end of the 12-month follow-up period was 54.2%, in group 2 - 56.1%. The complication rate (6.7%) in both groups did not differ statistically (p=0.683). The risk of arrhythmia recurrence didn’t depend on the strategy of cryoablation in postablation period (p=0.834). When conducting a single-factor analysis, a statistically significant effect on the probability of AF recurrence in the period of 3-12 months in group 1 was caused by AF recurrence in the blind period (95% confidence interval (CI): 1.5-27.7, p=0.013), in group 2 belonging to the female sex (95% CI: 1.2-24.6, p=0.032) and AF relapse in the blind period (95% CI: 1.5-128.5, p=0.020). During multivariate analysis in group 2, a statistically significant influence on the risk of AF recurrence in the period of 3-12 months was exerted by belonging to the female sex (hazard ratio (HR) 7.84; 95% CI 1478-42,23; p=0.016) and the presence of early AF recurrence (HR 20.36; 95% CI 1.99-208.23; p=0.011).Conclusion. Extended cryoablation in terms of efficiency and safety was comparable with the standard cryoablation. Early recurrence of AF (in the first 3 months after the intervention) turned out to be an independent risk factor for AF recurrence in the long-term period up to 12 months after cryoablation in both groups.
- 30 June 2022
- Published by APO Society of Specialists in Heart Failure in Kardiologiia
- Vol. 62 (6) , 23-29
Potential risk factors of atrial fibrillation recurrence after cryoballoon ablation
Aim To identify risk factors for recurrence of atrial fibrillation (AF) following cryoballoon ablation (CBA). Material and methods This prospective study included patients with paroxysmal AF who had undergone CBA (141 patients, median age 60 years, 3% men). The evaluation prior to CBA included clinical instrumental parameters (electrocardiography (ECG), 24-h ECG monitoring, echocardiography, contrast-enhanced cardiac multispiral computed tomography). Also, possible intraoperative indexes that could affect the CBA effectivity, were evaluated. The postoperative follow-up duration was 12 months. Effectivity was assessed during in-person visits at 3, 6, and 12 months, when questioning of patients and 24-h ECG monitoring were performed. CBA was considered ineffective if the patient had recurrences of any atrial tachyarrhythmia longer than 30 sec after the end of the 3-month “blind” period. Results During the 12-month follow-up, recurrences of atrial tachyarrhythmia were observed in 46 (32.6 %) patients. Patients with ineffective CBA more frequently had AF during the first 3 months (71.7 % vs. 11.6 %; рvs . 20.0 %; р=0.008), and stroke/recurrent ischemic attacks (15.2 % vs . 5.2 %; р=0.047). Multifactorial regression analysis showed that the factors of AF recurrence included common PV collector (relative risk (RR) 2.35; 95 % confidence interval (CI) 1.29–4.25; р=0.005), multiple ineffective AADs (RR 1.42; 95 % CI 1.08–1.86; р=0.011), and early AF recurrence (RR 7.57; 95 % CI 3.84–14.90; рConclusion Common PV collector and multiple ineffective AADs are risk factors of ineffective CBA. Early recurrences during the first 3 postoperative months are a significant risk factor of long-term AF recurrences.
- 30 June 2022
- Published by APO Society of Specialists in Heart Failure in Kardiologiia
- Vol. 62 (6) , 23-29
Potential risk factors of atrial fibrillation recurrence after cryoballoon ablation
Aim To identify risk factors for recurrence of atrial fibrillation (AF) following cryoballoon ablation (CBA). Material and methods This prospective study included patients with paroxysmal AF who had undergone CBA (141 patients, median age 60 years, 3% men). The evaluation prior to CBA included clinical instrumental parameters (electrocardiography (ECG), 24-h ECG monitoring, echocardiography, contrast-enhanced cardiac multispiral computed tomography). Also, possible intraoperative indexes that could affect the CBA effectivity, were evaluated. The postoperative follow-up duration was 12 months. Effectivity was assessed during in-person visits at 3, 6, and 12 months, when questioning of patients and 24-h ECG monitoring were performed. CBA was considered ineffective if the patient had recurrences of any atrial tachyarrhythmia longer than 30 sec after the end of the 3-month “blind” period. Results During the 12-month follow-up, recurrences of atrial tachyarrhythmia were observed in 46 (32.6 %) patients. Patients with ineffective CBA more frequently had AF during the first 3 months (71.7 % vs. 11.6 %; рvs . 20.0 %; р=0.008), and stroke/recurrent ischemic attacks (15.2 % vs . 5.2 %; р=0.047). Multifactorial regression analysis showed that the factors of AF recurrence included common PV collector (relative risk (RR) 2.35; 95 % confidence interval (CI) 1.29–4.25; р=0.005), multiple ineffective AADs (RR 1.42; 95 % CI 1.08–1.86; р=0.011), and early AF recurrence (RR 7.57; 95 % CI 3.84–14.90; рConclusion Common PV collector and multiple ineffective AADs are risk factors of ineffective CBA. Early recurrences during the first 3 postoperative months are a significant risk factor of long-term AF recurrences.
- Open Access
- 29 March 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (1) , 63-68
Takotsubo cardiomyopathy after cryoballoon pulmonary vein ablation in a patient with persistent atrial fibrillation: clinical case
We present a case of takotsubo cardiomyopathy characterized as acute transient left ventricular systolic dysfunction in a patient with persistent atrial fibrillation, that occurred after cryoballoon pulmonary vein ablation procedure.
- 29 March 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (1) , 63-68
Open AccessTakotsubo cardiomyopathy after cryoballoon pulmonary vein ablation in a patient with persistent atrial fibrillation: clinical case
We present a case of takotsubo cardiomyopathy characterized as acute transient left ventricular systolic dysfunction in a patient with persistent atrial fibrillation, that occurred after cryoballoon pulmonary vein ablation procedure.
- 8 August 2019
- Published by APO Society of Specialists in Heart Failure in Kardiologiia
- Vol. 59 (8) , 39-46
Electrophysiological Cardiac Parameters and Results of Antiarrhythmic Treatment in Patients with Paroxysmal Atrial Fibrillation (Lone and Associated with Arterial Hypertension)
Purpose: to assess cardiac electrophysiological parameters in patients with paroxysmal atrial fibrillation (AF), lone or with concomitant arterial hypertension (AH), and their prognostic significance relative to treatment effectiveness. Materials and methods . We included in this study 184 patients with paroxysmal AF (84 with concomitant AH and 100 with presumed lone AF). Cardiac electrophysiological study was performed in accordance with standardized protocol that included assessment of sinus node recovery time, sinoatrial, intraatrial and interatrial conduction time, and effective refractory periods (ERP) of right and left atria and atrioventricular node. Patients with inducible supraventricular reentrant arrhythmias that could potentially trigger AF underwent catheter radiofrequency ablation of those arrhythmias. Other patients received either antiarrhythmic drug therapy (AAD; n=79) or catheter cryo-ablation (CBA; n=81). Treatment was considered ineffective in case of any symptomatic or asymptomatic AF episode documented by ECG or Holter ECG within 12 months of follow-up. Results. Patients with lone AF compared with those with AH had shorter ERP of the right atrium (219±21 ms vs. 253±44 ms, respectively, p<0.05) and more prominent dispersion of ERP of right and left atria (median 40 ms, interquartile range 10-50 ms vs. median 20 ms, interquartile range 10-22.5 ms, respectively, p<0.05). There was no statistically significant difference in other electrophysiology parameters between the groups. Sustained supraventricular reentrant arrhythmias were induced in 9% (9 of 100) patients with presumed lone AF and in 1.2% (1 of 84) patients with AH (p<0.05). All these arrhythmias were successfully ablated, and patients had no AF recurrence during 12-month follow-up. Among other patient treatment (CBA n=81, AAD n=79) was effective in 64% of those with lone AFib and in 34% - with AH (p<0.05). In multivariate multiple regression analysis, none of electrophysiological parameters could be assumed as a factor associated with the efficacy of CBA or AAD. Conclusion. Patients with lone AF had more prominent atrial electrophysiological inhomogeneity compared with patients with concomitant AH. Cardiac electrophysiological parameters had no influence on effectiveness of antiarrhythmic treatment.
- 8 August 2019
- Published by APO Society of Specialists in Heart Failure in Kardiologiia
- Vol. 59 (8) , 39-46
Electrophysiological Cardiac Parameters and Results of Antiarrhythmic Treatment in Patients with Paroxysmal Atrial Fibrillation (Lone and Associated with Arterial Hypertension)
Purpose: to assess cardiac electrophysiological parameters in patients with paroxysmal atrial fibrillation (AF), lone or with concomitant arterial hypertension (AH), and their prognostic significance relative to treatment effectiveness. Materials and methods . We included in this study 184 patients with paroxysmal AF (84 with concomitant AH and 100 with presumed lone AF). Cardiac electrophysiological study was performed in accordance with standardized protocol that included assessment of sinus node recovery time, sinoatrial, intraatrial and interatrial conduction time, and effective refractory periods (ERP) of right and left atria and atrioventricular node. Patients with inducible supraventricular reentrant arrhythmias that could potentially trigger AF underwent catheter radiofrequency ablation of those arrhythmias. Other patients received either antiarrhythmic drug therapy (AAD; n=79) or catheter cryo-ablation (CBA; n=81). Treatment was considered ineffective in case of any symptomatic or asymptomatic AF episode documented by ECG or Holter ECG within 12 months of follow-up. Results. Patients with lone AF compared with those with AH had shorter ERP of the right atrium (219±21 ms vs. 253±44 ms, respectively, p<0.05) and more prominent dispersion of ERP of right and left atria (median 40 ms, interquartile range 10-50 ms vs. median 20 ms, interquartile range 10-22.5 ms, respectively, p<0.05). There was no statistically significant difference in other electrophysiology parameters between the groups. Sustained supraventricular reentrant arrhythmias were induced in 9% (9 of 100) patients with presumed lone AF and in 1.2% (1 of 84) patients with AH (p<0.05). All these arrhythmias were successfully ablated, and patients had no AF recurrence during 12-month follow-up. Among other patient treatment (CBA n=81, AAD n=79) was effective in 64% of those with lone AFib and in 34% - with AH (p<0.05). In multivariate multiple regression analysis, none of electrophysiological parameters could be assumed as a factor associated with the efficacy of CBA or AAD. Conclusion. Patients with lone AF had more prominent atrial electrophysiological inhomogeneity compared with patients with concomitant AH. Cardiac electrophysiological parameters had no influence on effectiveness of antiarrhythmic treatment.
- Open Access
- 1 January 2018
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 13 (3) , 10-15
Advances of balloon cryoablation for treatment of atrial fibrillation
Medical article медицинская статья
- 1 January 2018
- Published by Media Sphere Publishing Group in Russian Cardiology Bulletin
- Vol. 13 (3) , 10-15
Open AccessAdvances of balloon cryoablation for treatment of atrial fibrillation
Medical article медицинская статья