Toward imaging the body at 10.5 tesla
- 21 October 2016
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 434-443
Abstract
Purpose: To explore the potential of performing body imaging at 10.5 Tesla (T) compared with 7.0T through evaluating the transmit/receive performance of similarly configured dipole antenna arrays.Methods: Fractionated dipole antenna elements for 10.5T body imaging were designed and evaluated using numerical simulations. Transmit performance of antenna arrays inside the prostate, kidneys and heart were investigated and compared with those at 7.0T using both phase‐only radiofrequency (RF) shimming and multi‐spoke pulses. Signal‐to‐noise ratio (SNR) comparisons were also performed. A 10‐channel antenna array was constructed to image the abdomen of a swine at 10.5T. Numerical methods were validated with phantom studies at both field strengths.Results: Similar power efficiencies were observed inside target organs with phase‐only shimming, but RF nonuniformity was significantly higher at 10.5T. Spokes RF pulses allowed similar transmit performance with accompanying local specific absorption rate increases of 25–90% compared with 7.0T. Relative SNR gains inside the target anatomies were calculated to be >two‐fold higher at 10.5T, and 2.2‐fold SNR gain was measured in a phantom. Gradient echo and fast spin echo imaging demonstrated the feasibility of body imaging at 10.5T with the designed array.Conclusion: While comparable power efficiencies can be achieved using dipole antenna arrays with static shimming at 10.5T; increasing RF nonuniformities underscore the need for efficient, robust, and safe parallel transmission methods. Magn Reson Med 77:434–443, 2017. © 2016 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- National Cancer Institute (R01 CA155268)
- National Institute of Biomedical Imaging and Bioengineering (NIBIB P41 EB015894)
This publication has 58 references indexed in Scilit:
- Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationaleMagnetic Resonance Materials in Physics, Biology and Medicine, 2016
- Validating subject-specific RF and thermal simulations in the calf muscle using MR-based temperature measurementsMagnetic Resonance in Medicine, 2016
- A 16‐channel combined loop‐dipole transceiver array for 7 Tesla body MRIMagnetic Resonance in Medicine, 2016
- Universal pulses: A new concept for calibration‐free parallel transmissionMagnetic Resonance in Medicine, 2016
- Dipole antennas for ultrahigh‐field body imaging: a comparison with loop coilsNMR in Biomedicine, 2015
- A 7T spine array based on electric dipole transmittersMagnetic Resonance in Medicine, 2015
- 16‐channel bow tie antenna transceiver array for cardiac MR at 7.0 teslaMagnetic Resonance in Medicine, 2015
- Parallel transmission for ultrahigh‐field imagingNMR in Biomedicine, 2015
- MRI at 7 tesla and above: Demonstrated and potential capabilitiesJournal of Magnetic Resonance Imaging, 2014
- Design of a radiative surface coil array element at 7 T: The single‐side adapted dipole antennaMagnetic Resonance in Medicine, 2011