Optimisation of tube voltage for conventional urography using a Gd2O2S:Tb flat panel detector
- 11 March 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 139 (1-3) , 86-91
Abstract
With the increasing use of computed tomography (CT) for urography examinations, the indications for ‘conventional’ projection urography have changed and are more focused on high-contrast details. The purpose of the present study was to optimise the beam quality for urography examinations performed with a Gd2O2S:Tb flat-panel detector for the new conditions. Images of an anthropomorphic phantom were collected at different tube voltages with a CXDI-40G detector (Canon Inc., Tokyo, Japan). The images were analysed by radiologists and residents in a visual grading characteristics (VGCs) study. The tube voltage resulting in the best image quality was 55 kV, which therefore was selected for a clinical study. Images from 62 patients exposed with either 55 or 73 kV (original tube voltage) at constant effective doses were included. The 55-kV images underwent simulated dose reduction to represent images collected at 80, 64, 50, 40 and 32 % of the original dose level. All images were included in a VGC study where the observers rated the visibility of important anatomical landmarks. For images collected at 55 kV, an effective dose of ∼85 % resulted in the same image quality as for images collected at 73 kV at 100 % dose. In conclusion, a low tube voltage should be used for conventional urography focused on high-contrast details. The study indicates that using a tube voltage of 55 kV instead of 73 kV for a Gd2O2S:Tb flat-panel detector, the effective dose can be reduced by ∼10–20 % for normal-sized patients while maintaining image quality.Keywords
This publication has 6 references indexed in Scilit:
- Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluationBritish Journal of Radiology, 2007
- Reduction of absorbed dose in storage phosphor urography by significant lowering of tube voltage and adjustment of image display parametersActa Radiologica, 2005
- A software tool for increased efficiency in observer performance studies in radiologyRadiation Protection Dosimetry, 2005
- A conceptual optimisation strategy for radiography in a digital environmentRadiation Protection Dosimetry, 2005
- Method of simulating dose reduction for digital radiographic systemsRadiation Protection Dosimetry, 2005
- Evaluation of image quality in fluoroscopy by measurements and Monte Carlo calculationsPhysics in Medicine & Biology, 1995