Model-Independent Analysis of QCM Data on Colloidal Particle Adsorption
- 24 March 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 25 (9) , 5177-5184
Abstract
Quartz crystal microbalance (QCM) is widely used for studying soft interfaces in liquid environment. Many of these interfaces are heterogeneous in nature, in the sense that they are composed of discrete, isolated entities adsorbed at a surface. When characterizing such interfaces, one is interested in determining parameters such as surface coverage and size of the surface-adsorbed entities. The current strategy is to obtain this information by fitting QCM data—shifts in resonance frequency, ΔF, and bandwidth, ΔΓ—with the model derived for smooth, homogeneous films using the film acoustic thickness and shear elastic moduli as fitting parameters. Investigating adsorption of liposomes and icosahedral virus particles on inorganic surfaces of titania and gold, we demonstrate that the predictions of this model are at variance with the experimental observations. In particular, while the model predicts that the ratio between the bandwidth and frequency shifts, ΔΓ/ΔF (the Df ratio), should increase with both surface coverage and particle size, we observe that this ratio increases with increasing particle size but decreases with increasing surface coverage, demonstrating that QCM response in heterogeneous films, such as those composed of adsorbed colloidal particles, does not conform with the predictions of the homogeneous film model. Employing finite element method (FEM) calculations, we show that hydrodynamic effects are the cause of this discrepancy. Finally, we find that the size of the adsorbed colloidal particles can be recovered from a model-independent analysis of the plot of the ΔΓ/ΔF ratio versus the frequency shift on many overtones.Keywords
This publication has 38 references indexed in Scilit:
- Viscoelastic, mechanical, and dielectric measurements on complex samples with the quartz crystal microbalancePhysical Chemistry Chemical Physics, 2008
- Simultaneous Surface Plasmon Resonance and Quartz Crystal Microbalance with Dissipation Monitoring Measurements of Biomolecular Adsorption Events Involving Structural Transformations and Variations in Coupled WaterAnalytical Chemistry, 2004
- The role of surface science in bioengineered materialsSurface Science, 2002
- Biological surface scienceSurface Science, 2002
- Simultaneous frequency and dissipation factor QCM measurements of biomolecular adsorption and cell adhesionFaraday Discussions, 1997
- QCM Operation in Liquids: An Explanation of Measured Variations in Frequency and Q Factor with Liquid ConductivityAnalytical Chemistry, 1996
- Quartz crystal microbalance setup for frequency and Q-factor measurements in gaseous and liquid environmentsReview of Scientific Instruments, 1995
- In Situ Interfacial Mass Detection with Piezoelectric TransducersScience, 1990
- Damping of a crystal oscillator by an adsorbed monolayer and its relation to interfacial viscosityPhysical Review B, 1988
- Verwendung von Schwingquarzen zur W gung d nner Schichten und zur Mikrow gungThe European Physical Journal A, 1959