Dual-Channel FMCW Harmonic Radar With Active Tags at 61/122 GHz for Phase-Based Gait Parameter Monitoring
Open Access
- 8 August 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 9, 692-704
Abstract
Optimized rehabilitation after joint replacement surgery or other medical procedures affecting the musculoskeletal system requires practical movement analysis systems that enable the continuous and precise gait monitoring of patients in everyday life. To address this need, we present a system consisting of a frequency-modulated continuous-wave (FMCW) radar sensor and active frequency-doubling tags designed for accurate long-term monitoring. By using a harmonic measurement concept in which the tags double the frequency of the transceiver signal, a high signal-to-interference-and-noise ratio (SINR) is achieved, ensuring that the tags stand out clearly from the clutter produced by the leg. With our system, we particularly focus on a phase-based angle determination within the sagittal plane, enabled by two closely spaced receive antennas, allowing for more accurate and reliable gait monitoring compared to our previous system based on a bilateration method. By utilizing millimeter waves in the frequency range 56-63 GHz for transmission and 112-126 GHz for reception, we achieve a compact sensor size sufficient for the application. Based on measurements taken in a gait laboratory, we demonstrate that our system is capable of measuring the distance and angle between the sensor and tags during gait with an accuracy of up to 1.73 mm and 0.93°, respectively, using a stationary camera-based motion capture (MoCap) system as a reference.Keywords
Funding Information
- Bundesministerium f?r Bildung und Forschung (16KISK041)
- Federal state of North Rhine Westphalia and European Union (EFRE-0801736/EFRE-0801737)
This publication has 41 references indexed in Scilit:
- Do we still need to screen our patients?—Orthopaedic scoring based on motion trackingInternational Orthopaedics, 2023
- Gait variability analysis using continuous RF data streams of human activitySmart Health, 2022
- A Maritime Harmonic Radar Search and Rescue System Using Passive and Active Tags2021
- Active Reflector Tag for Millimeter Wave Harmonic Radar at 61/122 GHz ISM Band Based on 130 nm-BiCMOS SiGe:C Technology2020
- Doppler Radar for the Extraction of Biomechanical Parameters in Gait AnalysisIEEE Journal of Biomedical and Health Informatics, 2020
- Comparative Analysis of Gait Speed Estimation Using Wideband and Narrowband Radars, Thermal Camera, and Motion Tracking Suit TechnologiesJournal of Healthcare Informatics Research, 2020
- Assessment of the measurement accuracy of inertial sensors during different tasks of daily livingJournal of Biomechanics, 2019
- IMU-Based but Magnetometer-Free Joint Angle Estimation of Constrained Links2018
- Inertial measurement units: A brief state of the art on gait analysis2017
- SiGe HBT and BiCMOS process integration optimization within the DOTSEVEN project2015