Eddy current detection of broken wires in EMU coupler cables under large lift-off with identification of shielded strand interference
Authors:
- Yiran LiuYLYiran Liu
- Hongbao MaHMHongbao Ma
- Bo FengBo Feng
- Yanting ChenYCYanting Chen
- Jin LiJLJin Li
- Yihua KangYKYihua Kang
Preprint
- 24 June 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
Detecting broken wires in electric multiple unit (EMU) coupler cables in-situ is challenging due to large lift off (8 mm insulation), strong interference from a metallic shielding mesh, and poor field adaptability. This paper proposes a collaborative eddy current testing (ECT) method addressing excitation, reception, and signal identification. A vertical excitation strategy induces current crowding at the broken wire cross section. A narrow racetrack shaped asymmetric differential coil cancels common mode interference while avoiding signal cancellation, effectively overcoming lift off attenuation. A dual module ratio based method suppresses scanning speed variations and robustly distinguishes broken wires from the shielding mesh. Experiments show reliable detection of minor broken wires (≈25 % cross sectional loss) beneath 8 mm insulation, with a broken wire SNR ≥ 43.79 dB. Ratio based features for broken wires and the shielding mesh fall in 5–12.2 and ≤ 3, respectively, yielding a clear classification boundary. Repeatability tests on 16 artificial cables and progressive validation on an in service cable (intact → peeled → broken wire) confirm engineering potential, offering a compact, practical solution for in service health monitoring of coupler cables.Keywords
This publication has 37 references indexed in Scilit:
- Eddy Current Method in Non-Magnetic Aluminide Coating Thickness AssessmentJournal of Nondestructive Evaluation, 2025
- Failure analysis and residual life assessment of forged coupler yokesEngineering Failure Analysis, 2024
- A nondestructive high-resistance fault diagnosis method of XLPE medium voltage cables based on Chirp-TDRMeasurement, 2024
- Investigation of partial discharge characteristics in XLPE cable insulation under increasing electrical stressEngineering Failure Analysis, 2024
- Online multi-parameter sensing and condition assessment technology for power cables: A reviewElectric Power Systems Research, 2022
- Random vibration fatigue life assessment and optimization of a train buffer beam considering welding residual stressJournal of Mechanical Science and Technology, 2020
- Defect imaging curved surface based on flexible eddy current array sensorMeasurement, 2020
- Novel austenitic steel ageing classification method using eddy current testing and a support vector machineMeasurement, 2018
- Pulsed Eddy Current Testing of Carbon Steel Pipes’ Wall-thinning Through Insulation and CladdingJournal of Nondestructive Evaluation, 2012
- Wirbelströme im leitenden Halbraum bei beliebiger Form der erregenden LeiterschleifeElectrical Engineering, 1972