Abstract
Detecting broken wires in electric multiple unit (EMU) coupler cables in-situ is challenging due to large lift off (8 mm insulation), strong interference from a metallic shielding mesh, and poor field adaptability. This paper proposes a collaborative eddy current testing (ECT) method addressing excitation, reception, and signal identification. A vertical excitation strategy induces current crowding at the broken wire cross section. A narrow racetrack shaped asymmetric differential coil cancels common mode interference while avoiding signal cancellation, effectively overcoming lift off attenuation. A dual module ratio based method suppresses scanning speed variations and robustly distinguishes broken wires from the shielding mesh. Experiments show reliable detection of minor broken wires (≈25 % cross sectional loss) beneath 8 mm insulation, with a broken wire SNR ≥ 43.79 dB. Ratio based features for broken wires and the shielding mesh fall in 5–12.2 and ≤ 3, respectively, yielding a clear classification boundary. Repeatability tests on 16 artificial cables and progressive validation on an in service cable (intact → peeled → broken wire) confirm engineering potential, offering a compact, practical solution for in service health monitoring of coupler cables.

This publication has 37 references indexed in Scilit: