Yanting Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yanting Chen has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Bo Feng
Huazhong University of Science and Technology
10 shared publications - Yihua Kang
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
7 shared publications Yihua Kang
5 shared publications- Shenghan Wang
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
4 shared publications - Zhaoqi Duan
Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA
3 shared publications Hongbao Ma
2 shared publications
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Eddy current detection of broken wires in EMU coupler cables under large lift-off with identification of shielded strand interference
Detecting broken wires in electric multiple unit (EMU) coupler cables in-situ is challenging due to large lift off (8 mm insulation), strong interference from a metallic shielding mesh, and poor field adaptability. This paper proposes a collaborative eddy current testing (ECT) method addressing excitation, reception, and signal identification. A vertical excitation strategy induces current crowding at the broken wire cross section. A narrow racetrack shaped asymmetric differential coil cancels common mode interference while avoiding signal cancellation, effectively overcoming lift off attenuation. A dual module ratio based method suppresses scanning speed variations and robustly distinguishes broken wires from the shielding mesh. Experiments show reliable detection of minor broken wires (≈25 % cross sectional loss) beneath 8 mm insulation, with a broken wire SNR ≥ 43.79 dB. Ratio based features for broken wires and the shielding mesh fall in 5–12.2 and ≤ 3, respectively, yielding a clear classification boundary. Repeatability tests on 16 artificial cables and progressive validation on an in service cable (intact → peeled → broken wire) confirm engineering potential, offering a compact, practical solution for in service health monitoring of coupler cables.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEddy current detection of broken wires in EMU coupler cables under large lift-off with identification of shielded strand interference
Detecting broken wires in electric multiple unit (EMU) coupler cables in-situ is challenging due to large lift off (8 mm insulation), strong interference from a metallic shielding mesh, and poor field adaptability. This paper proposes a collaborative eddy current testing (ECT) method addressing excitation, reception, and signal identification. A vertical excitation strategy induces current crowding at the broken wire cross section. A narrow racetrack shaped asymmetric differential coil cancels common mode interference while avoiding signal cancellation, effectively overcoming lift off attenuation. A dual module ratio based method suppresses scanning speed variations and robustly distinguishes broken wires from the shielding mesh. Experiments show reliable detection of minor broken wires (≈25 % cross sectional loss) beneath 8 mm insulation, with a broken wire SNR ≥ 43.79 dB. Ratio based features for broken wires and the shielding mesh fall in 5–12.2 and ≤ 3, respectively, yielding a clear classification boundary. Repeatability tests on 16 artificial cables and progressive validation on an in service cable (intact → peeled → broken wire) confirm engineering potential, offering a compact, practical solution for in service health monitoring of coupler cables.
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Eddy current detection of broken wires in EMU coupler cables under large lift-off with identification of shielded strand interference
Detecting broken wires in electric multiple unit (EMU) coupler cables in-situ is challenging due to large lift off (8 mm insulation), strong interference from a metallic shielding mesh, and poor field adaptability. This paper proposes a collaborative eddy current testing (ECT) method addressing excitation, reception, and signal identification. A vertical excitation strategy induces current crowding at the broken wire cross section. A narrow racetrack shaped asymmetric differential coil cancels common mode interference while avoiding signal cancellation, effectively overcoming lift off attenuation. A dual module ratio based method suppresses scanning speed variations and robustly distinguishes broken wires from the shielding mesh. Experiments show reliable detection of minor broken wires (≈25 % cross sectional loss) beneath 8 mm insulation, with a broken wire SNR ≥ 43.79 dB. Ratio based features for broken wires and the shielding mesh fall in 5–12.2 and ≤ 3, respectively, yielding a clear classification boundary. Repeatability tests on 16 artificial cables and progressive validation on an in service cable (intact → peeled → broken wire) confirm engineering potential, offering a compact, practical solution for in service health monitoring of coupler cables.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEddy current detection of broken wires in EMU coupler cables under large lift-off with identification of shielded strand interference
Detecting broken wires in electric multiple unit (EMU) coupler cables in-situ is challenging due to large lift off (8 mm insulation), strong interference from a metallic shielding mesh, and poor field adaptability. This paper proposes a collaborative eddy current testing (ECT) method addressing excitation, reception, and signal identification. A vertical excitation strategy induces current crowding at the broken wire cross section. A narrow racetrack shaped asymmetric differential coil cancels common mode interference while avoiding signal cancellation, effectively overcoming lift off attenuation. A dual module ratio based method suppresses scanning speed variations and robustly distinguishes broken wires from the shielding mesh. Experiments show reliable detection of minor broken wires (≈25 % cross sectional loss) beneath 8 mm insulation, with a broken wire SNR ≥ 43.79 dB. Ratio based features for broken wires and the shielding mesh fall in 5–12.2 and ≤ 3, respectively, yielding a clear classification boundary. Repeatability tests on 16 artificial cables and progressive validation on an in service cable (intact → peeled → broken wire) confirm engineering potential, offering a compact, practical solution for in service health monitoring of coupler cables.
- 8 December 2025
- Published by Elsevier in Measurement
- Vol. 262
A novel crack angle measurement method based on tangential magnetic perturbation field (TMPF) under normal magnetization
- 8 December 2025
- Published by Elsevier in Measurement
- Vol. 262
A novel crack angle measurement method based on tangential magnetic perturbation field (TMPF) under normal magnetization
- 18 July 2025
- Published by Elsevier in NDT & E International
- Vol. 156
A nondestructive electrical conductivity imaging method based on carbon-coated magnetic particles
- 18 July 2025
- Published by Elsevier in NDT & E International
- Vol. 156
A nondestructive electrical conductivity imaging method based on carbon-coated magnetic particles
- Open Access
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 4, 1-7
Optimization of Magnet Dimension for MIEC Speed Sensor Using Gradient Projection Algorithm
Motion-induced eddy current (MIEC) testing method has been successfully applied in speed measurement, where the performance of the sensor is highly dependent on the dimensions of the permanent magnet. In this article, an optimization method based on the gradient projection algorithm is proposed to determine the optimal magnet dimensions and enhance measurement sensitivity. First, the principle of MIEC is analyzed based on a 2-D theoretical model. Subsequently, an optimization-based mathematical model employing the gradient projection algorithm is developed, and the corresponding optimized results are obtained. Finally, experimental validation is conducted using a rotating aluminum disk platform. The results indicate that, within the practical dimensional ranges of 40 mm in width and 30 mm in height, the optimized permanent magnet dimensions are with a width of 27.6 mm and a height of 30 mm, which yield the best measurement sensitivity.
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 4, 1-7
Open AccessOptimization of Magnet Dimension for MIEC Speed Sensor Using Gradient Projection Algorithm
Motion-induced eddy current (MIEC) testing method has been successfully applied in speed measurement, where the performance of the sensor is highly dependent on the dimensions of the permanent magnet. In this article, an optimization method based on the gradient projection algorithm is proposed to determine the optimal magnet dimensions and enhance measurement sensitivity. First, the principle of MIEC is analyzed based on a 2-D theoretical model. Subsequently, an optimization-based mathematical model employing the gradient projection algorithm is developed, and the corresponding optimized results are obtained. Finally, experimental validation is conducted using a rotating aluminum disk platform. The results indicate that, within the practical dimensional ranges of 40 mm in width and 30 mm in height, the optimized permanent magnet dimensions are with a width of 27.6 mm and a height of 30 mm, which yield the best measurement sensitivity.
- 13 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Feature Enhancement Method for Magnetic Particle Testing Based on Isolation Strip
Magnetic particle testing (MT) has the advantages of high sensitivity and adaptability. However, during the formation of magnetic particle indication (MPI) corresponding to surface opening defects, the defects are filled with magnetic particles, resulting in the weakening of the leakage magnetic field (LMF), a phenomenon that has been ignored in existing studies. In order to enhance the visual feature of MPI, this paper proposes an isolation strip-based magnetic particle testing method (ISMT), which can avoid the attenuation of LMF. Meanwhile, ISMT can isolate the surface conditions of the specimen to avoid the formation of pseudo-magnetic particle indication (PMPI). The enhancement principle of ISMT is analyzed by simulation. Comparative experiments between ISMT and traditional MT were conducted to verify the visual enhancement effect of ISMT on defects of multiple depths. The results show that the enhancement effect of ISMT is 1.51 times, 1.36 times, and 1.08 times for the standard test shims of 60/100, 30/100, and 15/100, respectively. In addition, the advantage of ISMT in detecting larger defects is verified by experiments on hole defects of different sizes, and the isolation effect against surface oil stains is discussed.
- 13 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Feature Enhancement Method for Magnetic Particle Testing Based on Isolation Strip
Magnetic particle testing (MT) has the advantages of high sensitivity and adaptability. However, during the formation of magnetic particle indication (MPI) corresponding to surface opening defects, the defects are filled with magnetic particles, resulting in the weakening of the leakage magnetic field (LMF), a phenomenon that has been ignored in existing studies. In order to enhance the visual feature of MPI, this paper proposes an isolation strip-based magnetic particle testing method (ISMT), which can avoid the attenuation of LMF. Meanwhile, ISMT can isolate the surface conditions of the specimen to avoid the formation of pseudo-magnetic particle indication (PMPI). The enhancement principle of ISMT is analyzed by simulation. Comparative experiments between ISMT and traditional MT were conducted to verify the visual enhancement effect of ISMT on defects of multiple depths. The results show that the enhancement effect of ISMT is 1.51 times, 1.36 times, and 1.08 times for the standard test shims of 60/100, 30/100, and 15/100, respectively. In addition, the advantage of ISMT in detecting larger defects is verified by experiments on hole defects of different sizes, and the isolation effect against surface oil stains is discussed.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (6) , 8251-8262
3-D Vision Based Magnetic Particle Indication Measuring for Identification and Evaluation of Cracks in Hub Bearing Raceway
Surface cracks in the raceway of hub bearings pose a significant safety threat. Magnetic particle testing (MPT) can be used to locate these cracks regardless of the influences caused by raceway structure. However, crack identification and evaluation in conventional MPT are quite challenging due to the low correlation between magnetic particle indication (MPI) and inspection images. To address this problem, this article introduces a dynamical MPI measuring method through 3-D vision. Specifically, a scanning 3-D vision system, an approach to forming MPI, and a curvature feature–based algorithm for MPI identification are newly proposed. 3-D measurement directly captures the spatial aggregation state of the magnetic particles, thereby enabling the connection between MPI and the cause of it, which is the leakage magnetic field above cracks. Starting from the electromagnetic field, we analyze the potential features of the 3-D profile of MPI. Magnetic force serves as a link, providing a theoretical basis for the identification and evaluation. Experiments show that our method successfully detects artificial notches with depths of 0.5–2.5 mm and natural microcracks with a maximum width of 40 μ m and differentiates between variations in crack depths of 0.5 mm. The sensitivity, stability, and evaluation ability can be demonstrated.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (6) , 8251-8262
3-D Vision Based Magnetic Particle Indication Measuring for Identification and Evaluation of Cracks in Hub Bearing Raceway
Surface cracks in the raceway of hub bearings pose a significant safety threat. Magnetic particle testing (MPT) can be used to locate these cracks regardless of the influences caused by raceway structure. However, crack identification and evaluation in conventional MPT are quite challenging due to the low correlation between magnetic particle indication (MPI) and inspection images. To address this problem, this article introduces a dynamical MPI measuring method through 3-D vision. Specifically, a scanning 3-D vision system, an approach to forming MPI, and a curvature feature–based algorithm for MPI identification are newly proposed. 3-D measurement directly captures the spatial aggregation state of the magnetic particles, thereby enabling the connection between MPI and the cause of it, which is the leakage magnetic field above cracks. Starting from the electromagnetic field, we analyze the potential features of the 3-D profile of MPI. Magnetic force serves as a link, providing a theoretical basis for the identification and evaluation. Experiments show that our method successfully detects artificial notches with depths of 0.5–2.5 mm and natural microcracks with a maximum width of 40 μ m and differentiates between variations in crack depths of 0.5 mm. The sensitivity, stability, and evaluation ability can be demonstrated.
- 30 August 2023
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 202
Automatic crack identification using a novel 3D profilometry-based magnetic particle testing method
- 30 August 2023
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 202
Automatic crack identification using a novel 3D profilometry-based magnetic particle testing method
- 23 April 2022
- Published by Springer Nature in Journal of Nondestructive Evaluation
A Novel AC-MFL Probe Based on the Parallel Cables Magnetizing Technique
Sensor technology is the fundamental part of intelligent manufacturing. Considering the advantages of the flexible sensor, such as being light in weight and applicable to arbitrarily curvilinear surfaces, it has become a research hotspot in the past few years. The alternating current magnetic flux leakage (AC-MFL) testing method plays a crucial role in the ferromagnetic materials manufacturing industry. However, the commonly used U-shape yoke magnetizers are large in size and difficult to be implemented on various curved surfaces, which limits the application of the method. An AC-MFL detection method based on powered parallel cables (PCs) is proposed. Furthermore, a flexible AC-MFL probe with integrating magnetizer and magnetic sensors is developed. It can be implemented in a limited space and is feasible to test parts with various curved surfaces. The finite element analysis method was used to analyze the origin of the crack signal. The directionality of the probe was analyzed and verified. In order to trade off the sensitivity and the detection stability of the probe, sensors should be placed above PC. The overall width of PC should be greater than 10 mm and less than 15 mm. Finally, the sensitivity and directionality of the probe was verified by the experiments; the application example of detecting the transition zone of a drill pipe is presented.
- 23 April 2022
- Published by Springer Nature in Journal of Nondestructive Evaluation
A Novel AC-MFL Probe Based on the Parallel Cables Magnetizing Technique
Sensor technology is the fundamental part of intelligent manufacturing. Considering the advantages of the flexible sensor, such as being light in weight and applicable to arbitrarily curvilinear surfaces, it has become a research hotspot in the past few years. The alternating current magnetic flux leakage (AC-MFL) testing method plays a crucial role in the ferromagnetic materials manufacturing industry. However, the commonly used U-shape yoke magnetizers are large in size and difficult to be implemented on various curved surfaces, which limits the application of the method. An AC-MFL detection method based on powered parallel cables (PCs) is proposed. Furthermore, a flexible AC-MFL probe with integrating magnetizer and magnetic sensors is developed. It can be implemented in a limited space and is feasible to test parts with various curved surfaces. The finite element analysis method was used to analyze the origin of the crack signal. The directionality of the probe was analyzed and verified. In order to trade off the sensitivity and the detection stability of the probe, sensors should be placed above PC. The overall width of PC should be greater than 10 mm and less than 15 mm. Finally, the sensitivity and directionality of the probe was verified by the experiments; the application example of detecting the transition zone of a drill pipe is presented.