Extraction of Respiration Rate from Wrist ECG Signals
Authors:
- 1 December 2021
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0565-0570
Abstract
Respiratory behavior is one of the important parameters that indicate any physiological changes in human body. However, using a respiration sensor device for continuous monitoring is inconvenient and expensive. In this paper, an approach to acquire the respiration signal from the wrist electrocardiogram (ECG) is proposed. An analog front end (AFE) sampled at 100 Hz is used to collect ECG signals from the wrist to compute and verify the corresponding heart rate (HR) with a commercial ECG device. Signal processing mechanisms are applied on the raw data to denoise the ECG signal. The captured ECG signal is further processed to extract a breathing pattern to calculate a respiration rate (RR) in breath per minute (BPM). The extracted BPMs are compared with a commercial respiration monitor to validate the data by following a protocol at 5 different BPMs (12, 15, 20, 24 and 30). For each BPM, commercial respiration monitor is validated at first. Then, data are taken simultaneously wearing wrist electrodes and commercial respiratory device to validate the performance of our proposed method at different BPMs. The results indicate high accuracy of the proposed system which is low-cost, simpler to implement, can be integrated with a wearable device and remove the demand of any dedicated sensor for RR measurements.Keywords
Funding Information
- National Science Foundation
This publication has 21 references indexed in Scilit:
- Development of a real-time breathing-rate monitor using difference operation method and adaptive windowing on dry-electrode ECG signal2017
- Respiratory Rate Estimation by Using ECG, Impedance, and Motion Sensing in Smart ClothingJournal of Medical and Biological Engineering, 2017
- Application of iterated Hilbert transform for deriving respiratory signal from single-lead ECG2016
- Respiration Disorders Classification With Informative Features for m-Health ApplicationsIEEE Journal of Biomedical and Health Informatics, 2016
- A robust detection algorithm to identify breathing peaks in respiration signals from spontaneously breathing subjects2015
- Basic study on the most relaxing respiration period in children to aid the development of a respiration-leading stuffed toy2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2014
- Accurate interpretation of the 12-lead ECG electrode placement: A systematic reviewHealth Education Journal, 2013
- Automatic breathing segmentation from wearable respiration sensors2011
- Willem Einthoven and the Birth of Clinical Electrocardiography a Hundred Years AgoCardiac Electrophysiology Review, 2003
- Product specificationBuilding Research & Information, 1993