Mahfuzur Rahman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mahfuzur Rahman has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Bashir I. Morshed
Texas Tech University,Department of Computer Science,Lubbock,TX,USA,79409
4 shared publications- Bashir I. Morshed
Department of Computer Science, Texas Tech University, Lubbock, TX 79409, USA
3 shared publications Robert Hewitt
University of Memphis,Department of Engineering Technology,Memphis,TN,USA,38152
1 shared publication- Ucchwas Talukder Utsha
Department of Computer Science, Texas Tech University, Lubbock, TX 79409, USA
1 shared publication
Latest Publications
- Open Access
- 4 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2463
A Novel Real-Time Intelligent Axis Selection Based on Body Positions with Simultaneous Cardiac and Respiratory Signal Using an Edge Wearable for Smart Health Applications
Real-time simultaneous monitoring of cardiac and respiratory signals in wearable systems remains challenging due to motion artifacts under varying body postures. This paper proposes an edge wearable integrated with novel methods to acquire and process cardiac and respiratory signals simultaneously from the chest. For respiration monitoring, the system captures chest motion using an IMU and applies dynamic filtering with real-time axis selection in a custom mobile application. It automatically selects the best respiratory axis from six IMU vectors: x, y, z, xy, yz, and zx, improving robustness across body postures and device placements. The proposed system can also capture and process electrocardiogram (ECG) data simultaneously for cardiac monitoring. Cardiac and respiration data were taken from eight healthy subjects, including males and females, followed by five protocols. The overall mean absolute error (MAE) for eight subjects is found to be 0.64 breath per minute (BrPM) after validation by a commercial sensor. In real time, the wearable continuously provides ECG and breathing signal streaming, ECG beat detection, and cardiac and breathing rates with an overall latency of 13.8 ms. The results indicate that the system can monitor the cardio-respiratory signals in real time under static and light-movement conditions.
- 4 June 2026
- Published by MDPI AG in Electronics
- Vol. 15 (11) , 2463
Open AccessA Novel Real-Time Intelligent Axis Selection Based on Body Positions with Simultaneous Cardiac and Respiratory Signal Using an Edge Wearable for Smart Health Applications
Real-time simultaneous monitoring of cardiac and respiratory signals in wearable systems remains challenging due to motion artifacts under varying body postures. This paper proposes an edge wearable integrated with novel methods to acquire and process cardiac and respiratory signals simultaneously from the chest. For respiration monitoring, the system captures chest motion using an IMU and applies dynamic filtering with real-time axis selection in a custom mobile application. It automatically selects the best respiratory axis from six IMU vectors: x, y, z, xy, yz, and zx, improving robustness across body postures and device placements. The proposed system can also capture and process electrocardiogram (ECG) data simultaneously for cardiac monitoring. Cardiac and respiration data were taken from eight healthy subjects, including males and females, followed by five protocols. The overall mean absolute error (MAE) for eight subjects is found to be 0.64 breath per minute (BrPM) after validation by a commercial sensor. In real time, the wearable continuously provides ECG and breathing signal streaming, ECG beat detection, and cardiac and breathing rates with an overall latency of 13.8 ms. The results indicate that the system can monitor the cardio-respiratory signals in real time under static and light-movement conditions.
- Open Access
- 31 October 2025
- Published by MDPI AG in Electronics
- Vol. 14 (21) , 4276
CardioResp Device: Hardware and Firmware of an Embedded Wearable for Real-Time ECG and Respiration in Dynamic Settings
Monitoring electrocardiogram (ECG) and respiration continuously and non-invasively is essential for managing cardiopulmonary health. An effective wearable device can be used to regularly monitor key vitals, reducing the need for clinical visits. In this work, we propose a custom device for real-time continuous ECG by inkjet printed (IJP) dry electrodes and respiration monitoring by using a novel single 6-axis inertial measurement unit (IMU). The proposed system can extract the heart rate (HR) and respiration rate (RR) during static and dynamic postures. The respiration process implements a quaternion-based update and multiple filtering stages to estimate the signal. The custom device uses Bluetooth protocol to send the raw and processed data to a mobile application. The RR is investigated in stationary, i.e., sitting and standing, and dynamic, i.e., walking, running, and cycling, postures. The proposed device is evaluated with commercial Go Direct® respiration belt from Vernier® for RR and offers an overall accuracy of 99.3% and 98.6% for static and dynamic conditions, respectively. The wearable also offers 98.9% and 97.9% accuracy for HR measurements, respectively, in static and active postures when compared with the Kardia® device. Furthermore, the device is assessed in an ambulatory monitoring setup in both indoor and outdoor environments. The low-power wearable consumes an average of only 7.4 mA of current during data processing. The device performs effectively and efficiently in both stationary and active states, offering a low complexity, portable solution for real-time monitoring. The proposed system can benefit from the continuous monitoring and early detection of pulmonary and cardio-respiratory health issues.
- 31 October 2025
- Published by MDPI AG in Electronics
- Vol. 14 (21) , 4276
Open AccessCardioResp Device: Hardware and Firmware of an Embedded Wearable for Real-Time ECG and Respiration in Dynamic Settings
Monitoring electrocardiogram (ECG) and respiration continuously and non-invasively is essential for managing cardiopulmonary health. An effective wearable device can be used to regularly monitor key vitals, reducing the need for clinical visits. In this work, we propose a custom device for real-time continuous ECG by inkjet printed (IJP) dry electrodes and respiration monitoring by using a novel single 6-axis inertial measurement unit (IMU). The proposed system can extract the heart rate (HR) and respiration rate (RR) during static and dynamic postures. The respiration process implements a quaternion-based update and multiple filtering stages to estimate the signal. The custom device uses Bluetooth protocol to send the raw and processed data to a mobile application. The RR is investigated in stationary, i.e., sitting and standing, and dynamic, i.e., walking, running, and cycling, postures. The proposed device is evaluated with commercial Go Direct® respiration belt from Vernier® for RR and offers an overall accuracy of 99.3% and 98.6% for static and dynamic conditions, respectively. The wearable also offers 98.9% and 97.9% accuracy for HR measurements, respectively, in static and active postures when compared with the Kardia® device. Furthermore, the device is assessed in an ambulatory monitoring setup in both indoor and outdoor environments. The low-power wearable consumes an average of only 7.4 mA of current during data processing. The device performs effectively and efficiently in both stationary and active states, offering a low complexity, portable solution for real-time monitoring. The proposed system can benefit from the continuous monitoring and early detection of pulmonary and cardio-respiratory health issues.
- Open Access
- 30 June 2025
- Published by MDPI AG in Electronics
- Vol. 14 (13) , 2654
Resource-Constrained On-Chip AI Classifier for Beat-by-Beat Real-Time Arrhythmia Detection with an ECG Wearable System
The electrocardiogram (ECG) is one of the vital physiological signals for human health. Lightweight neural network (NN) models integrated into a low-resource wearable device can benefit the user with a low-power, real-time edge computing system for continuous and daily monitoring. This work introduces a novel edge-computing wearable device for real-time beat-by-beat ECG arrhythmia classification. The proposed wearable integrates the light AI model into a 32-bit ARM® Cortex™-based custom printed circuit board (PCB). The work analyzes the performance of artificial neural network (ANN), convolutional neural network (CNN), and long short-term memory (LSTM) models for real-time wearable implementation. The wearable is capable of real-time QRS detection and feature extraction from raw ECG data. The QRS detection algorithm offers high reliability with a 99.5% F1 score and R-peak position error (RPE) of 6.3 ms for R-peak-to-R-peak intervals. The proposed method implements a combination of top time series, spectral, and signal-specific features for model development. Lightweight, pretrained models are deployed on the custom wearable and evaluated in real time using mock data from the MIT-BIH dataset. We propose an LSTM model that provides efficient performance over accuracy, inference latency, and memory consumption. The proposed model offers 98.1% accuracy, with 98.2% sensitivity and 99.5% specificity while testing in real time on the wearable. Real-time inferencing takes 20 ms, and the device consumes as low as 5.9 mA of power. The proposed method achieves efficient performance in real-time testing, which indicates the wearable can be effectively used for real-time continuous arrhythmia detection.
- 30 June 2025
- Published by MDPI AG in Electronics
- Vol. 14 (13) , 2654
Open AccessResource-Constrained On-Chip AI Classifier for Beat-by-Beat Real-Time Arrhythmia Detection with an ECG Wearable System
The electrocardiogram (ECG) is one of the vital physiological signals for human health. Lightweight neural network (NN) models integrated into a low-resource wearable device can benefit the user with a low-power, real-time edge computing system for continuous and daily monitoring. This work introduces a novel edge-computing wearable device for real-time beat-by-beat ECG arrhythmia classification. The proposed wearable integrates the light AI model into a 32-bit ARM® Cortex™-based custom printed circuit board (PCB). The work analyzes the performance of artificial neural network (ANN), convolutional neural network (CNN), and long short-term memory (LSTM) models for real-time wearable implementation. The wearable is capable of real-time QRS detection and feature extraction from raw ECG data. The QRS detection algorithm offers high reliability with a 99.5% F1 score and R-peak position error (RPE) of 6.3 ms for R-peak-to-R-peak intervals. The proposed method implements a combination of top time series, spectral, and signal-specific features for model development. Lightweight, pretrained models are deployed on the custom wearable and evaluated in real time using mock data from the MIT-BIH dataset. We propose an LSTM model that provides efficient performance over accuracy, inference latency, and memory consumption. The proposed model offers 98.1% accuracy, with 98.2% sensitivity and 99.5% specificity while testing in real time on the wearable. Real-time inferencing takes 20 ms, and the device consumes as low as 5.9 mA of power. The proposed method achieves efficient performance in real-time testing, which indicates the wearable can be effectively used for real-time continuous arrhythmia detection.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Design and Packaging of a Custom Single-lead Electrocardiogram (ECG) Sensor Embedded with Wireless Transmission
An embedded device is developed to acquire an electrocardiogram (ECG) signal by using only a single lead. The device is capable to capture the ECG signal of a human from the wrist or heart region and transmit data through Bluetooth low energy (BLE). The device includes a custom printed circuit board (PCB) for ECG acquisition. The custom PCB implements the AD 8232 chip for ECG calculation. The PCB is embedded with a commercial nRF52840 development board. Analog data from custom PCB is converted to the digital domain by using a 10-bit analog to digital converter (ADC) and transmitted through Bluetooth 5.3 both supplied by the development board. nRF52840 is 32 bit ARM ® Cortex™ processing unit. The BLE data is transmitted by a baud rate of 115.2 kbps. The PCB is 2-layer (32 mm X 50 mm X 4 mm). The device is powered by a 350 mA-hr LiPo battery and consumes approximately 0.58 mA of current. With this current consumption, the battery would last around 603 hours. Finally, all parts are packaged in a box to make it compact and functional for body-worn uses. The device is a low-cost, low-weight design suitable for mobile health (mHealth) applications.
- 14 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Design and Packaging of a Custom Single-lead Electrocardiogram (ECG) Sensor Embedded with Wireless Transmission
An embedded device is developed to acquire an electrocardiogram (ECG) signal by using only a single lead. The device is capable to capture the ECG signal of a human from the wrist or heart region and transmit data through Bluetooth low energy (BLE). The device includes a custom printed circuit board (PCB) for ECG acquisition. The custom PCB implements the AD 8232 chip for ECG calculation. The PCB is embedded with a commercial nRF52840 development board. Analog data from custom PCB is converted to the digital domain by using a 10-bit analog to digital converter (ADC) and transmitted through Bluetooth 5.3 both supplied by the development board. nRF52840 is 32 bit ARM ® Cortex™ processing unit. The BLE data is transmitted by a baud rate of 115.2 kbps. The PCB is 2-layer (32 mm X 50 mm X 4 mm). The device is powered by a 350 mA-hr LiPo battery and consumes approximately 0.58 mA of current. With this current consumption, the battery would last around 603 hours. Finally, all parts are packaged in a box to make it compact and functional for body-worn uses. The device is a low-cost, low-weight design suitable for mobile health (mHealth) applications.
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0565-0570
Extraction of Respiration Rate from Wrist ECG Signals
Respiratory behavior is one of the important parameters that indicate any physiological changes in human body. However, using a respiration sensor device for continuous monitoring is inconvenient and expensive. In this paper, an approach to acquire the respiration signal from the wrist electrocardiogram (ECG) is proposed. An analog front end (AFE) sampled at 100 Hz is used to collect ECG signals from the wrist to compute and verify the corresponding heart rate (HR) with a commercial ECG device. Signal processing mechanisms are applied on the raw data to denoise the ECG signal. The captured ECG signal is further processed to extract a breathing pattern to calculate a respiration rate (RR) in breath per minute (BPM). The extracted BPMs are compared with a commercial respiration monitor to validate the data by following a protocol at 5 different BPMs (12, 15, 20, 24 and 30). For each BPM, commercial respiration monitor is validated at first. Then, data are taken simultaneously wearing wrist electrodes and commercial respiratory device to validate the performance of our proposed method at different BPMs. The results indicate high accuracy of the proposed system which is low-cost, simpler to implement, can be integrated with a wearable device and remove the demand of any dedicated sensor for RR measurements.
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 0565-0570
Extraction of Respiration Rate from Wrist ECG Signals
Respiratory behavior is one of the important parameters that indicate any physiological changes in human body. However, using a respiration sensor device for continuous monitoring is inconvenient and expensive. In this paper, an approach to acquire the respiration signal from the wrist electrocardiogram (ECG) is proposed. An analog front end (AFE) sampled at 100 Hz is used to collect ECG signals from the wrist to compute and verify the corresponding heart rate (HR) with a commercial ECG device. Signal processing mechanisms are applied on the raw data to denoise the ECG signal. The captured ECG signal is further processed to extract a breathing pattern to calculate a respiration rate (RR) in breath per minute (BPM). The extracted BPMs are compared with a commercial respiration monitor to validate the data by following a protocol at 5 different BPMs (12, 15, 20, 24 and 30). For each BPM, commercial respiration monitor is validated at first. Then, data are taken simultaneously wearing wrist electrodes and commercial respiratory device to validate the performance of our proposed method at different BPMs. The results indicate high accuracy of the proposed system which is low-cost, simpler to implement, can be integrated with a wearable device and remove the demand of any dedicated sensor for RR measurements.
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Estimation of Respiration Rate using an Inertial Measurement Unit Placed on Thorax-Abdomen
Respiration rate is one of the important measures of any physiological changes in human body. In this paper, an inertial measurement unit (IMU) is used to detect the chest movement and estimate the respiration rate from the real-time signal. A commercial inertial motion sensor chip used in this study that produces linear motion vector as streaming data. The signal from the motion sensor was sampled at 10 Hz. Signal processing was applied to denoise respiration signals from the values of linear motion vectors. Then, an algorithm of calculating respiration rate, was used to estimate breath per minute (BPM). The results were compared with a commercial respiration monitor belt logger sensor as the ground truth. The IMU sensor was tested at 5 different BPMs (12, 15, 20, 24, and 30) to validate the data from the IMU sensor and from the commercial respiration belt using a protocol where different BPM was maintained. The results show high accuracy of the proposed system which is simpler to use, cheaper to protype, and can be integrated with a wearable device and a custom smartphone app using edge computing technique.
- 14 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Estimation of Respiration Rate using an Inertial Measurement Unit Placed on Thorax-Abdomen
Respiration rate is one of the important measures of any physiological changes in human body. In this paper, an inertial measurement unit (IMU) is used to detect the chest movement and estimate the respiration rate from the real-time signal. A commercial inertial motion sensor chip used in this study that produces linear motion vector as streaming data. The signal from the motion sensor was sampled at 10 Hz. Signal processing was applied to denoise respiration signals from the values of linear motion vectors. Then, an algorithm of calculating respiration rate, was used to estimate breath per minute (BPM). The results were compared with a commercial respiration monitor belt logger sensor as the ground truth. The IMU sensor was tested at 5 different BPMs (12, 15, 20, 24, and 30) to validate the data from the IMU sensor and from the commercial respiration belt using a protocol where different BPM was maintained. The results show high accuracy of the proposed system which is simpler to use, cheaper to protype, and can be integrated with a wearable device and a custom smartphone app using edge computing technique.