Setting up a quantitative SPECT imaging network for a European multi-centre dosimetry study of radioiodine treatment for thyroid cancer as part of the MEDIRAD project
Authors:
- Jan TaproggeJTJan Taprogge
- Francesca LeekFLFrancesca Leek
- Tino SchurratTSTino Schurrat
- Johannes Tran-GiaJTJohannes Tran-Gia
- Delphine VallotDVDelphine Vallot
- Manuel BardièsMBManuel Bardiès
- Uta EberleinUEUta Eberlein
- Michael LassmannMLMichael Lassmann
- Susanne SchlöglSSSusanne Schlögl
- Alex Vergara GilAGAlex Vergara Gil
- Glenn D. FluxGFGlenn D. Flux
- Andreas BuckABAndreas Buck
Open Access
- 8 October 2020
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 7 (1) , 1-14
Abstract
Background: Differentiated thyroid cancer has been treated with radioiodine for almost 80 years, although controversial questions regarding radiation-related risks and the optimisation of treatment regimens remain unresolved. Multi-centre clinical studies are required to ensure recruitment of sufficient patients to achieve the statistical significance required to address these issues. Optimisation and standardisation of data acquisition and processing are necessary to ensure quantitative imaging and patient-specific dosimetry. Material and methods: A European network of centres able to perform standardised quantitative imaging of radioiodine therapy of thyroid cancer patients was set-up within the EU consortium MEDIRAD. This network will support a concurrent series of clinical studies to determine accurately absorbed doses for thyroid cancer patients treated with radioiodine. Five SPECT(/CT) systems at four European centres were characterised with respect to their system volume sensitivity, recovery coefficients and dead time. Results: System volume sensitivities of the Siemens Intevo systems (crystal thickness 3/8″) ranged from 62.1 to 73.5 cps/MBq. For a GE Discovery 670 (crystal thickness 5/8″) a system volume sensitivity of 92.2 cps/MBq was measured. Recovery coefficients measured on three Siemens Intevo systems show good agreement. For volumes larger than 10 ml, the maximum observed difference between recovery coefficients was found to be ± 0.02. Furthermore, dead-time coefficients measured on two Siemens Intevo systems agreed well with previously published dead-time values. Conclusions: Results presented here provide additional support for the proposal to use global calibration parameters for cameras of the same make and model. This could potentially facilitate the extension of the imaging network for further dosimetry-based studies.Keywords
Funding Information
- Horizon 2020 (755523)
- National Institute for Health Research NIHR (NA)
This publication has 31 references indexed in Scilit:
- Development of patient‐specific molecular imaging phantoms using a 3D printerMedical Physics, 2014
- MIRD Pamphlet No. 24: Guidelines for Quantitative 131I SPECT in Dosimetry ApplicationsJournal of Nuclear Medicine, 2013
- Dosimetry for audit and clinical trials: challenges and requirementsJournal of Physics: Conference Series, 2013
- Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancerMedical Physics, 2011
- 131I Activity for Remnant Ablation in Patients with Differentiated Thyroid Cancer: A Systematic ReviewThe Journal of Clinical Endocrinology & Metabolism, 2007
- Radiation Dose Assessment for I-131 Therapy of Thyroid Cancer Using I-124 PET ImagingClinical Positron Imaging, 1999
- Dosimetric Considerations in the Radioiodine Treatment of Macrometastases and Micrometastases from Differentiated Thyroid CancerThyroid®, 1997
- Radiation dose assessment in radioiodine therapy. Dose-response relationships in differentiated thyroid carcinoma using quantitative scanning and PETRadiotherapy and Oncology, 1993
- Radiation dose assessment in radioiodine therapy. 2. Practical implementation using quantitative scanning and PET, with initial results on thyroid carcinomaRadiotherapy and Oncology, 1989
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979