Patient-specific instrumentation (PSI) has recently been introduced to improve the alignment following total knee arthroplasty (TKA). However, controversy remains between PSI and conventional instrumentation. The aim of this study is to compare the accuracy of PSI with conventional instruments for total knee arthroplasty (TKA). A systematic literature search was performed in databases including PubMed, the Cochrane Library, EMBASE, and Web of Science. All of the available randomized, controlled trials (RCTs) or non-randomized, controlled trials (nRCTs) comparing PSI with conventional instruments for TKA were identified. A statistical analysis was performed of this meta-analysis. Eighteen studies with 2417 patients were included in the authors’ final analysis. The results of the meta-analysis demonstrated that there were no statistical differences in outliers of the mechanical axis (risk ratio [RR], 0.84; 95% confidence interval [CI], 0.61–1.11), the femoral component in the coronal (RR, 0.56; 95% CI, 0.32–1.05) and sagittal (RR, 0.83; 95% CI, 0.60–1.14) plane, the tibial component in the coronal (RR, 0.84; 95% CI, 0.52–1.35) and sagittal (RR, 1.04; 95% CI, 0.69–1.55) plane, and the femoral component rotation (RR, 1.02; 95% CI, 0.57, 1.83) between the 2 groups. In addition, subgroup analysis showed that the study design and imaging used for preoperative scanning did not affect the outcome of the alignment, but a different PSI system might. The authors’ meta-analysis indicated that the accuracy of PSI was not superior to conventional instruments for patients undergoing TKA. Future RCTs should focus on functional outcomes and component survivorship with mid- to long-term follow-up. [ Orthopedics. 2015; 38(4):e305–e313.]Keywords
This publication has 37 references indexed in Scilit:
- The Value of Patient-Matched Instrumentation in Total Knee ArthroplastyThe Journal of Arthroplasty, 2012
- The effect of femoral component rotation on the kinematics of the tibiofemoral and patellofemoral joints after total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- Computer-assisted TKA: Greater Precision, Doubtful Clinical Efficacy: AffirmsOrthopedics, 2009
- Results of an Initial Experience With Custom-fit Positioning Total Knee Arthroplasty in a Series of 48 PatientsOrthopedics, 2008
- Orthopaedic Surgeon Workforce and Volume Assessment for Total Hip and Knee Replacement in the United States: Preparing for an EpidemicJournal of Bone and Joint Surgery, 2008
- The Cost-Effectiveness of Computer-Assisted Navigation in Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2007
- Computer-assisted Total Knee Arthroplasty Using Patient-specific TemplatingClinical Orthopaedics and Related Research, 2006
- Health-Related Quality of Life in Total Hip and Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2004
- Why Are Total Knee Arthroplasties Failing Today?Clinical Orthopaedics and Related Research, 2002