An Assessment of Indoor Air Quality in the Arrivals Hall of Beirut–Rafic Hariri International Airport: Monitoring of VOCs and NO2
Open Access
- 20 March 2021
- journal article
- research article
- Published by MDPI AG in Atmosphere
- Vol. 12 (3) , 400
Abstract
In Beirut–Rafic Hariri International Airport (RHIA), airport employees stay at least 12 h inside the airport’s buildings and suffer from respiratory symptoms. Additionally, direct openings exist between the apron and the arrivals hall providing a pathway for contaminated air to enter the buildings. Hence, we study the impact of Beirut–RHIA’s activities on the indoor air of the arrivals hall (impact on employees and passengers) during June, November, and October 2014. Due to their impacts on air quality and human health, assessing of the concentrations of nitrogen dioxide (NO2) and Volatile Organic Compounds (VOCs) was the target of our study by using gas chromatographic techniques (GC-MS and GC-FID) for VOCs and calorimetric methods for NO2 concentrations. NO2 levels indicated a probable hazard to the health of passengers and employees, while measured VOC levels did not present any risks except for acrolein. This is the first study to assess the speciation of a large number of VOCs (46 VOCs) for airport indoor air while revealing a very interesting correlation between aircraft number and the concentrations of VOC groups (namely heavy alkanes, aldehydes and ketones, and monoaromatics). Moreover, this is the first study in Lebanon to assess the speciation of a large number of VOCs in indoor air.Keywords
This publication has 30 references indexed in Scilit:
- Exposure and health impact evaluation based on simultaneous measurement of indoor and ambient PM2.5 in Haidian, BeijingEnvironmental Pollution, 2017
- Seasonality and indoor/outdoor relationships of flame retardants and PCBs in residential airEnvironmental Pollution, 2016
- Association of indoor air pollution from coal combustion with influenza-like illness in housewivesEnvironmental Pollution, 2016
- Assessment of indoor and outdoor PM species at schools and residences in a high-altitude Ecuadorian urban centerEnvironmental Pollution, 2016
- Assessment of polycyclic aromatic hydrocarbons in indoor and outdoor air of preschool environments (3–5 years old children)Environmental Pollution, 2016
- Influences of ambient air PM2.5 concentration and meteorological condition on the indoor PM2.5 concentrations in a residential apartment in Beijing using a new approachEnvironmental Pollution, 2015
- Spatial and temporal variation of outdoor and indoor exposure of volatile organic compounds in Greater CairoAtmospheric Pollution Research, 2010
- Exposure Evaluation to Airborne Polycyclic Aromatic Hydrocarbons in an Italian AirportJournal of Occupational and Environmental Medicine, 2006
- Aldehyde measurements in indoor environments in Strasbourg (France)Atmospheric Environment, 2006
- Seasonal cycle of VOCs in apartmentsIndoor Air, 2003