Céline Liaud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Céline Liaud has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Stéphane Le Calvé
Institute for Chemistry and Processes for Energy, the Environment and Health (ICPEES), UMR 7515, CNRS/University of Strasbourg, Strasbourg, 67087, France
3 shared publications - Claire Trocquet
Université de Strasbourg, CNRS, ICPEES UMR 7515, F-67000 Strasbourg, France
1 shared publication - Isabelle Malandain
Université de Strasbourg, CNRS, ICPEES UMR 7515, F-67000 Strasbourg, France
1 shared publication - Jocelyne Adjizian Gérard
Department of Geography, CREEMO (Centre de Recherche en Environnement-Espace Méditerrannée Orientale), Saint Joseph University, Beirut 17-5208, Lebanon
1 shared publication - Maher Abboud
UEGP Unité Environnement, Génomique et Protéomique, Faculty of Sciences, Saint Joseph University, BP 17-5208 Mar Mikhael, Beirut 1104 2020, Lebanon
1 shared publication - Maud Guglielmino
Université de Strasbourg, CNRS, ICPEES UMR 7515, F-67000 Strasbourg, France
1 shared publication
Latest Publications
- Open Access
- 20 March 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (3) , 400
An Assessment of Indoor Air Quality in the Arrivals Hall of Beirut–Rafic Hariri International Airport: Monitoring of VOCs and NO2
In Beirut–Rafic Hariri International Airport (RHIA), airport employees stay at least 12 h inside the airport’s buildings and suffer from respiratory symptoms. Additionally, direct openings exist between the apron and the arrivals hall providing a pathway for contaminated air to enter the buildings. Hence, we study the impact of Beirut–RHIA’s activities on the indoor air of the arrivals hall (impact on employees and passengers) during June, November, and October 2014. Due to their impacts on air quality and human health, assessing of the concentrations of nitrogen dioxide (NO2) and Volatile Organic Compounds (VOCs) was the target of our study by using gas chromatographic techniques (GC-MS and GC-FID) for VOCs and calorimetric methods for NO2 concentrations. NO2 levels indicated a probable hazard to the health of passengers and employees, while measured VOC levels did not present any risks except for acrolein. This is the first study to assess the speciation of a large number of VOCs (46 VOCs) for airport indoor air while revealing a very interesting correlation between aircraft number and the concentrations of VOC groups (namely heavy alkanes, aldehydes and ketones, and monoaromatics). Moreover, this is the first study in Lebanon to assess the speciation of a large number of VOCs in indoor air.
- 20 March 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (3) , 400
Open AccessAn Assessment of Indoor Air Quality in the Arrivals Hall of Beirut–Rafic Hariri International Airport: Monitoring of VOCs and NO2
In Beirut–Rafic Hariri International Airport (RHIA), airport employees stay at least 12 h inside the airport’s buildings and suffer from respiratory symptoms. Additionally, direct openings exist between the apron and the arrivals hall providing a pathway for contaminated air to enter the buildings. Hence, we study the impact of Beirut–RHIA’s activities on the indoor air of the arrivals hall (impact on employees and passengers) during June, November, and October 2014. Due to their impacts on air quality and human health, assessing of the concentrations of nitrogen dioxide (NO2) and Volatile Organic Compounds (VOCs) was the target of our study by using gas chromatographic techniques (GC-MS and GC-FID) for VOCs and calorimetric methods for NO2 concentrations. NO2 levels indicated a probable hazard to the health of passengers and employees, while measured VOC levels did not present any risks except for acrolein. This is the first study to assess the speciation of a large number of VOCs (46 VOCs) for airport indoor air while revealing a very interesting correlation between aircraft number and the concentrations of VOC groups (namely heavy alkanes, aldehydes and ketones, and monoaromatics). Moreover, this is the first study in Lebanon to assess the speciation of a large number of VOCs in indoor air.
- Open Access
- 13 January 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (1) , 108
Simultaneous Monitoring of Particle-Bound PAHs Inside a Low-Energy School Building and Outdoors over Two Weeks in France
The emergence of new super-insulated buildings to reduce energy consumption can lead to a degradation of the indoor air quality. While some studies were carried out to assess the air quality in these super-insulated buildings, they were usually focused on the measurement of gas phase pollutants such as carbon dioxide and volatile organic compounds. This work reports the first measurements of Polycyclic Aromatic Hydrocarbons (PAHs) associated with particles as a function of time and particle size in a low-energy building. The airborne particles were collected indoors and outdoors over three to four days of sampling using two three-stage cascade impactors allowing to sample simultaneously particles with aerodynamic diameter Dae > 10 µm, 2.5 µm < Dae < 10 µm, 1 µm < Dae < 2.5 µm, and Dae < 1 µm. The 16 US-EPA priority PAHs were then extracted and quantified by high-performance liquid chromatography (HPLC) coupled to fluorescence detection. The resulting total particle concentrations were low, in the ranges 3.73 to 9.66 and 0.60 to 8.83 µg m-3 for indoors and outdoors, respectively. Thirteen PAHs were always detected in all the samples. The total PAH concentrations varied between 290 and 415 pg m−3 depending on the particle size, the environment (indoors or outdoors) and the sampling period considered. More interestingly, the temporal variations of individual PAHs highlighted that high molecular weight PAHs were mainly associated to the finest particles and some of them exhibited similar temporal behaviors, suggesting a common emission source. The indoor-to-outdoor concentration ratios of individual PAH were usually found close to or less than 1, except during the event combining rainy conditions and limited indoor ventilation rate.
- 13 January 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (1) , 108
Open AccessSimultaneous Monitoring of Particle-Bound PAHs Inside a Low-Energy School Building and Outdoors over Two Weeks in France
The emergence of new super-insulated buildings to reduce energy consumption can lead to a degradation of the indoor air quality. While some studies were carried out to assess the air quality in these super-insulated buildings, they were usually focused on the measurement of gas phase pollutants such as carbon dioxide and volatile organic compounds. This work reports the first measurements of Polycyclic Aromatic Hydrocarbons (PAHs) associated with particles as a function of time and particle size in a low-energy building. The airborne particles were collected indoors and outdoors over three to four days of sampling using two three-stage cascade impactors allowing to sample simultaneously particles with aerodynamic diameter Dae > 10 µm, 2.5 µm < Dae < 10 µm, 1 µm < Dae < 2.5 µm, and Dae < 1 µm. The 16 US-EPA priority PAHs were then extracted and quantified by high-performance liquid chromatography (HPLC) coupled to fluorescence detection. The resulting total particle concentrations were low, in the ranges 3.73 to 9.66 and 0.60 to 8.83 µg m-3 for indoors and outdoors, respectively. Thirteen PAHs were always detected in all the samples. The total PAH concentrations varied between 290 and 415 pg m−3 depending on the particle size, the environment (indoors or outdoors) and the sampling period considered. More interestingly, the temporal variations of individual PAHs highlighted that high molecular weight PAHs were mainly associated to the finest particles and some of them exhibited similar temporal behaviors, suggesting a common emission source. The indoor-to-outdoor concentration ratios of individual PAH were usually found close to or less than 1, except during the event combining rainy conditions and limited indoor ventilation rate.
- Open Access
- 30 November 2019
- Published by MDPI AG in Atmosphere
- Vol. 10 (12) , 763
Near Real-Time Monitoring of Formaldehyde in a Low-Energy School Building
The emergence of new super-insulated buildings to reduce energy consumption places the quality of indoor air at the center of the debate. Among the indoor air pollutants, aldehydes are often present, and formaldehyde is of major interest regarding its multiple sources and its health impact. Therefore, French regulations expect to reduce formaldehyde concentrations below 10 μg m−3 in public buildings by 2023. Formaldehyde and other aldehydes were measured for two weeks during an intensive field campaign conducted in a school recently built and equipped with programmable dual-flow ventilation. Aldehydes were monitored with the ISO 16000-3 reference method based on sampling with 2,4-dinitrophenylhydrazine (DNPH) tubes while formaldehyde concentration was continuously measured by using a sensitive near real-time formaldehyde microanalyzer with a detection limit of 1 µg m−3. Formaldehyde was the major aldehyde. Its concentrations varied in the range of 2–25 µg m−3 and decreased by half when mechanical ventilation was ON, while the other ones were always below 5 µg m−3. In addition, an excellent agreement was observed between the different analytical techniques deployed to quantify formaldehyde levels. The microanalyzer was able to measure fast variations of formaldehyde concentration in the studied room, according to the building's ventilation periods.
- 30 November 2019
- Published by MDPI AG in Atmosphere
- Vol. 10 (12) , 763
Open AccessNear Real-Time Monitoring of Formaldehyde in a Low-Energy School Building
The emergence of new super-insulated buildings to reduce energy consumption places the quality of indoor air at the center of the debate. Among the indoor air pollutants, aldehydes are often present, and formaldehyde is of major interest regarding its multiple sources and its health impact. Therefore, French regulations expect to reduce formaldehyde concentrations below 10 μg m−3 in public buildings by 2023. Formaldehyde and other aldehydes were measured for two weeks during an intensive field campaign conducted in a school recently built and equipped with programmable dual-flow ventilation. Aldehydes were monitored with the ISO 16000-3 reference method based on sampling with 2,4-dinitrophenylhydrazine (DNPH) tubes while formaldehyde concentration was continuously measured by using a sensitive near real-time formaldehyde microanalyzer with a detection limit of 1 µg m−3. Formaldehyde was the major aldehyde. Its concentrations varied in the range of 2–25 µg m−3 and decreased by half when mechanical ventilation was ON, while the other ones were always below 5 µg m−3. In addition, an excellent agreement was observed between the different analytical techniques deployed to quantify formaldehyde levels. The microanalyzer was able to measure fast variations of formaldehyde concentration in the studied room, according to the building's ventilation periods.