A Review on Surface Stress-Based Miniaturized Piezoresistive SU-8 Polymeric Cantilever Sensors
Open Access
- 2 February 2018
- journal article
- review article
- Published by Springer Nature in Nano-Micro Letters
- Vol. 10 (2) , 1-41
Abstract
In the last decade, microelectromechanical systems (MEMS) SU-8 polymeric cantilevers with piezoresistive readout combined with the advances in molecular recognition techniques have found versatile applications, especially in the field of chemical and biological sensing. Compared to conventional solid-state semiconductor-based piezoresistive cantilever sensors, SU-8 polymeric cantilevers have advantages in terms of better sensitivity along with reduced material and fabrication cost. In recent times, numerous researchers have investigated their potential as a sensing platform due to high performance-to-cost ratio of SU-8 polymer-based cantilever sensors. In this article, we critically review the design, fabrication, and performance aspects of surface stress-based piezoresistive SU-8 polymeric cantilever sensors. The evolution of surface stress-based piezoresistive cantilever sensors from solid-state semiconductor materials to polymers, especially SU-8 polymer, is discussed in detail. Theoretical principles of surface stress generation and their application in cantilever sensing technology are also devised. Variants of SU-8 polymeric cantilevers with different composition of materials in cantilever stacks are explained. Furthermore, the interdependence of the material selection, geometrical design parameters, and fabrication process of piezoresistive SU-8 polymeric cantilever sensors and their cumulative impact on the sensor response are also explained in detail. In addition to the design-, fabrication-, and performance-related factors, this article also describes various challenges in engineering SU-8 polymeric cantilevers as a universal sensing platform such as temperature and moisture vulnerability. This review article would serve as a guideline for researchers to understand specifics and functionality of surface stress-based piezoresistive SU-8 cantilever sensors.Keywords
This publication has 269 references indexed in Scilit:
- Air-Coupled Piezoelectric Transducers with Active Polypropylene Foam Matching LayersSensors, 2013
- Cyclic olefin copolymer based microfluidic devices for biochip applications: Ultraviolet surface grafting using 2-methacryloyloxyethyl phosphorylcholineBiomicrofluidics, 2012
- Adsorption induced surface-stress sensing signal originating from both vertical interface effects and intermolecular lateral interactionsThe Analyst, 2011
- Approaches to Increasing Surface Stress for Improving Signal-to-Noise Ratio of Microcantilever SensorsAnalytical Chemistry, 2010
- Design optimization of piezoresistive cantilevers for force sensing in air and waterJournal of Applied Physics, 2009
- In vivo wireless ethanol vapor detection in the Wistar ratSensors and Actuators B: Chemical, 2009
- SU-8 force sensing pillar arrays for biological measurementsLab on a Chip, 2009
- Crystalline silicon cantilevers for piezoresistive detection of biomolecular forcesMicroelectronic Engineering, 2008
- Dry release of all-polymer structuresMicroelectronic Engineering, 2005
- Flow behaviour of thin polymer films used for hot embossing lithographyMicroelectronic Engineering, 2000