7 Tesla MR imaging of the human eye in vivo
Open Access
- 23 October 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (5) , 924-932
Abstract
Purpose: To develop a protocol which optimizes contrast, resolution and scan time for three‐dimensional (3D) imaging of the human eye in vivo using a 7 Tesla (T) scanner and custom radio frequency (RF) coil.Materials and Methods: Initial testing was conducted to reduce motion and susceptibility artifacts. Three‐dimensional FFE and IR‐TFE images were obtained with variable flip angles and TI times. T1 measurements were made and numerical simulations were performed to determine the ideal contrast of certain ocular structures. Studies were performed to optimize resolution and signal‐to‐noise ratio (SNR) with scan times from 20 s to 5 min.Results: Motion and susceptibility artifacts were reduced through careful subject preparation. T1 values of the ocular structures are in line with previous work at 1.5T. A voxel size of 0.15 × 0.25 × 1.0 mm3 was obtained with a scan time of approximately 35 s for both 3D FFE and IR‐TFE sequences. Multiple images were registered in 3D to produce final SNRs over 40.Conclusion: Optimization of pulse sequences and avoidance of susceptibility and motion artifacts led to high quality images with spatial resolution and SNR exceeding prior work. Ocular imaging at 7T with a dedicated coil improves the ability to make measurements of the fine structures of the eye. J. Magn. Reson. Imaging 2009;30:924–932.Keywords
This publication has 31 references indexed in Scilit:
- Age-related changes in optical and biometric characteristics of emmetropic eyesJournal of Vision, 2008
- Development of a robust method for generating 7.0 T multichannel phase images of the brain with application to normal volunteers and patients with neurological diseasesNeuroImage, 2008
- T1 and T2 measurements of the fine structures of the in vivo and enucleated human eyeJournal of Magnetic Resonance Imaging, 2007
- High-Field-Strength Magnetic ResonanceTopics in Magnetic Resonance Imaging, 2007
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- Demonstration of an Anterior Diffusional Pathway for Solutes in the Normal Human Eye with High Spatial Resolution Contrast-Enhanced Dynamic MR ImagingInvestigative Ophthalmology & Visual Science, 2006
- Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diametersJournal of Cataract & Refractive Surgery, 2006
- In‐depth study of the electromagnetics of ultrahigh‐field MRINMR in Biomedicine, 2006
- Optimization of 3-D MP-RAGE Sequences for Structural Brain ImagingNeuroImage, 2000