Petra Schmalbrock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Petra Schmalbrock has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Donald W. Chakeres
Department of Radiology, The Ohio State University, Columbus, OH 43210, USA
5 shared publications - Michael V. Knopp
Department of Radiology, The Ohio State University, Columbus, OH, USA
3 shared publications - Allahyar Kangarlu
MRI Facility, 1630 Upham Drive, Columbus, OH 43210
2 shared publications - Amir Abduljalil
Wright Center of Innovation in Biomedical Imaging, Department of Radiology, The Ohio State University, 395 W 12(th), Columbus, OH 43210, United States
2 shared publications - Huyen T. Nguyen
The Ohio State University
2 shared publications Michael V. Knopp
Department of Radiology, Wright Center of Innovation, The Ohio State University, Columbus, OH, USA
2 shared publications
Latest Publications
- Open Access
Eccentric-focused rehabilitation promotes myelin plasticity in individuals with chronic, incomplete spinal cord injury
Background: Myelin plasticity has emerged as a novel mechanism by which the nervous system can change with experience, offering new potential for rehabilitation-induced recovery after neurotrauma. This first-in-human study investigated whether innovative, downhill locomotor rehabilitation promotes myelin plasticity in individuals with chronic, incomplete spinal cord injury (SCI). Methods: Of 20 individuals with SCI that enrolled, 4 passed the imaging screen and had myelin water imaging (MWI) before and after a 12-week (3 times/week) downhill locomotor treadmill training program (SCI+DH). One individual was excluded for imaging artifacts. Uninjured control participants (n=7) had two MWI sessions within the same day. Changes in myelin water fraction (MWF), a histopathologically-validated myelin biomarker, were analyzed in a priori motor learning and non-motor learning brain regions and the cervical spinal cord using statistical approaches appropriate for small sample sizes. Results: Within SCI+DH individuals, significantly more motor learning regions showed increased MWF than non-motor learning regions (p<.05). Compared to Control, MWF in the SCI+DH group increased in white matter underlying postcentral and precuneus cortices, combined motor learning brain regions, and ventral spinal cord (p<.05). To account for small sample size, an estimation-based approach showed the pattern of MWF increase was specific to training and region. Conclusion: Downhill training increased MWF in brain regions specifically associated with motor learning and in the ventral spinal cord. Trial Registration: ClincialTrials.gov ( NCT02498548 , NCT02821845 ) Funding: National Institutes of Health [F31NS096921 (TDF), R21HD082808 (DMB)], Craig H. Neilsen Foundation [316282 (DMB)], Foundation for Physical Therapy Research [Promotion of Doctoral Studies Level II Scholarship (TDF)]
Open AccessEccentric-focused rehabilitation promotes myelin plasticity in individuals with chronic, incomplete spinal cord injury
Background: Myelin plasticity has emerged as a novel mechanism by which the nervous system can change with experience, offering new potential for rehabilitation-induced recovery after neurotrauma. This first-in-human study investigated whether innovative, downhill locomotor rehabilitation promotes myelin plasticity in individuals with chronic, incomplete spinal cord injury (SCI). Methods: Of 20 individuals with SCI that enrolled, 4 passed the imaging screen and had myelin water imaging (MWI) before and after a 12-week (3 times/week) downhill locomotor treadmill training program (SCI+DH). One individual was excluded for imaging artifacts. Uninjured control participants (n=7) had two MWI sessions within the same day. Changes in myelin water fraction (MWF), a histopathologically-validated myelin biomarker, were analyzed in a priori motor learning and non-motor learning brain regions and the cervical spinal cord using statistical approaches appropriate for small sample sizes. Results: Within SCI+DH individuals, significantly more motor learning regions showed increased MWF than non-motor learning regions (p<.05). Compared to Control, MWF in the SCI+DH group increased in white matter underlying postcentral and precuneus cortices, combined motor learning brain regions, and ventral spinal cord (p<.05). To account for small sample size, an estimation-based approach showed the pattern of MWF increase was specific to training and region. Conclusion: Downhill training increased MWF in brain regions specifically associated with motor learning and in the ventral spinal cord. Trial Registration: ClincialTrials.gov ( NCT02498548 , NCT02821845 ) Funding: National Institutes of Health [F31NS096921 (TDF), R21HD082808 (DMB)], Craig H. Neilsen Foundation [316282 (DMB)], Foundation for Physical Therapy Research [Promotion of Doctoral Studies Level II Scholarship (TDF)]
- 1 September 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 61, 233-238
MRI-based methodology to monitor the impact of positional changes on the airway caliber in obstructive sleep apnea patients
- 1 September 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 61, 233-238
MRI-based methodology to monitor the impact of positional changes on the airway caliber in obstructive sleep apnea patients
- Open Access
- 26 November 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (3) , 439-446
Basal Ganglia Iron in Patients with Multiple Sclerosis Measured with 7T Quantitative Susceptibility Mapping Correlates with Inhibitory Control
BACKGROUND AND PURPOSE: T2 hypointensity in the basal ganglia of patients with MS has been associated with clinical progression and cognitive decline. Our objectives were the following: 1) to compare signal in T2WI, R2 (ie, 1/T2), and R2* (ie, 1/T2*) relaxation rates and quantitative susceptibility mapping; and 2) to investigate the associations among MR imaging, clinical scores, and cognitive measures of inhibitory control linked to basal ganglia functioning. MATERIALS AND METHODS: Twenty-nine patients with MS underwent a battery of neuropsychological tests including the Flanker and Stroop tasks. 7T MR imaging included 3D gradient-echo and single-echo multishot spin-echo EPI. Quantitative susceptibility mapping images were calculated by using a Wiener filter deconvolution algorithm. T2WI signal was normalized to CSF. R2 and R2* were calculated by log-linear regression. Average MR imaging metrics for the globus pallidus, putamen, and caudate were computed from manually traced ROIs including the largest central part of each structure. RESULTS: Marked spatial variation was consistently visualized on quantitative susceptibility mapping and T2/T2*WI within each basal ganglia structure. MR imaging metrics correlated with each other for each basal ganglia structure individually. Notably, caudate and putamen quantitative susceptibility mapping metrics were similar, but the putamen R2 was larger than the caudate R2. This finding suggests that tissue features contribute differently to R2 and quantitative susceptibility mapping. Caudate and anterior putamen quantitative susceptibility mapping correlated with the Flanker but not Stroop measures; R2 did not correlate with inhibitory control measures. Putamen quantitative susceptibility mapping and caudate and putamen R2 correlated with the Expanded Disability Status Scale. CONCLUSIONS: Our study showed that quantitative susceptibility mapping and R2 may be complementary indicators for basal ganglia tissue changes in MS. Our findings are consistent with the hypothesis that decreased performance of basal ganglia–reliant tasks involving inhibitory control is associated with increased quantitative susceptibility mapping.
- 26 November 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (3) , 439-446
Open AccessBasal Ganglia Iron in Patients with Multiple Sclerosis Measured with 7T Quantitative Susceptibility Mapping Correlates with Inhibitory Control
BACKGROUND AND PURPOSE: T2 hypointensity in the basal ganglia of patients with MS has been associated with clinical progression and cognitive decline. Our objectives were the following: 1) to compare signal in T2WI, R2 (ie, 1/T2), and R2* (ie, 1/T2*) relaxation rates and quantitative susceptibility mapping; and 2) to investigate the associations among MR imaging, clinical scores, and cognitive measures of inhibitory control linked to basal ganglia functioning. MATERIALS AND METHODS: Twenty-nine patients with MS underwent a battery of neuropsychological tests including the Flanker and Stroop tasks. 7T MR imaging included 3D gradient-echo and single-echo multishot spin-echo EPI. Quantitative susceptibility mapping images were calculated by using a Wiener filter deconvolution algorithm. T2WI signal was normalized to CSF. R2 and R2* were calculated by log-linear regression. Average MR imaging metrics for the globus pallidus, putamen, and caudate were computed from manually traced ROIs including the largest central part of each structure. RESULTS: Marked spatial variation was consistently visualized on quantitative susceptibility mapping and T2/T2*WI within each basal ganglia structure. MR imaging metrics correlated with each other for each basal ganglia structure individually. Notably, caudate and putamen quantitative susceptibility mapping metrics were similar, but the putamen R2 was larger than the caudate R2. This finding suggests that tissue features contribute differently to R2 and quantitative susceptibility mapping. Caudate and anterior putamen quantitative susceptibility mapping correlated with the Flanker but not Stroop measures; R2 did not correlate with inhibitory control measures. Putamen quantitative susceptibility mapping and caudate and putamen R2 correlated with the Expanded Disability Status Scale. CONCLUSIONS: Our study showed that quantitative susceptibility mapping and R2 may be complementary indicators for basal ganglia tissue changes in MS. Our findings are consistent with the hypothesis that decreased performance of basal ganglia–reliant tasks involving inhibitory control is associated with increased quantitative susceptibility mapping.
- Open Access
- 12 November 2015
- Published by Elsevier in NeuroImage: Clinical
- Vol. 10, 129-139
Frontoparietal white matter integrity predicts haptic performance in chronic stroke
- 12 November 2015
- Published by Elsevier in NeuroImage: Clinical
- Vol. 10, 129-139
Open AccessFrontoparietal white matter integrity predicts haptic performance in chronic stroke
- 30 September 2012
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 30 (7) , 907-915
Detecting cortical lesions in multiple sclerosis at 7 T using white matter signal attenuation
- 30 September 2012
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 30 (7) , 907-915
Detecting cortical lesions in multiple sclerosis at 7 T using white matter signal attenuation
- Open Access
- 23 October 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (5) , 924-932
7 Tesla MR imaging of the human eye in vivo
Purpose: To develop a protocol which optimizes contrast, resolution and scan time for three‐dimensional (3D) imaging of the human eye in vivo using a 7 Tesla (T) scanner and custom radio frequency (RF) coil.Materials and Methods: Initial testing was conducted to reduce motion and susceptibility artifacts. Three‐dimensional FFE and IR‐TFE images were obtained with variable flip angles and TI times. T1 measurements were made and numerical simulations were performed to determine the ideal contrast of certain ocular structures. Studies were performed to optimize resolution and signal‐to‐noise ratio (SNR) with scan times from 20 s to 5 min.Results: Motion and susceptibility artifacts were reduced through careful subject preparation. T1 values of the ocular structures are in line with previous work at 1.5T. A voxel size of 0.15 × 0.25 × 1.0 mm3 was obtained with a scan time of approximately 35 s for both 3D FFE and IR‐TFE sequences. Multiple images were registered in 3D to produce final SNRs over 40.Conclusion: Optimization of pulse sequences and avoidance of susceptibility and motion artifacts led to high quality images with spatial resolution and SNR exceeding prior work. Ocular imaging at 7T with a dedicated coil improves the ability to make measurements of the fine structures of the eye. J. Magn. Reson. Imaging 2009;30:924–932.
- 23 October 2009
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (5) , 924-932
Open Access7 Tesla MR imaging of the human eye in vivo
Purpose: To develop a protocol which optimizes contrast, resolution and scan time for three‐dimensional (3D) imaging of the human eye in vivo using a 7 Tesla (T) scanner and custom radio frequency (RF) coil.Materials and Methods: Initial testing was conducted to reduce motion and susceptibility artifacts. Three‐dimensional FFE and IR‐TFE images were obtained with variable flip angles and TI times. T1 measurements were made and numerical simulations were performed to determine the ideal contrast of certain ocular structures. Studies were performed to optimize resolution and signal‐to‐noise ratio (SNR) with scan times from 20 s to 5 min.Results: Motion and susceptibility artifacts were reduced through careful subject preparation. T1 values of the ocular structures are in line with previous work at 1.5T. A voxel size of 0.15 × 0.25 × 1.0 mm3 was obtained with a scan time of approximately 35 s for both 3D FFE and IR‐TFE sequences. Multiple images were registered in 3D to produce final SNRs over 40.Conclusion: Optimization of pulse sequences and avoidance of susceptibility and motion artifacts led to high quality images with spatial resolution and SNR exceeding prior work. Ocular imaging at 7T with a dedicated coil improves the ability to make measurements of the fine structures of the eye. J. Magn. Reson. Imaging 2009;30:924–932.
- 1 April 2009
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 181 (S 01) , WI_PO43
Time-of-Flight und Phase Contrast Magnetresonanzangiographie der intrazerebralen Arterien im Ultrahochfeld
Ziele: Ziel dieser Studie war es die Möglichkeit der Time-of-Flight (ToF) und Phase Contrast (PC) Magnetresonanzangiographie (MRA) der intrazerebralen Arterien im Ultrahochfeld 7T Magnetresonanztomographen zu untersuchen und der Vergleich mit konventionellen 1,5T und 3T Systemen. Methode: PC und TOF MRAs wurden in einem 7T MR Tomographen (Achieva, Philips) und in klinischen 3T (Achieva, Philips) and 1.5T (Signa, GE) Tomographen mit Birdcage-Kopfspulen akquiriert. 3D PC (TR:8–15ms; TE:3–4ms; FA:12–20°; FoV: 240mm; Matrix:512×384) und 3D TOF (TR:15–25ms; TE:3–4ms; FA:18–20°; FoV:240mm; Matrix:512×384) Sequenzen mit einer Schichtdicke von 0,75mm wurden in der transversalen Ebene aufgenommen. Diese schlossen die gesamte Gefäßanatomie des Circulus Willisii ein. PC und TOF Bilder wurden in ähnlichen Akquisitionszeiten von 5 Minuten aufgenommen. Die Darstellung der distalen Zweige cerebralen Arterien wurde ausgewertet. Zusätzlich wurde die Signal zu Rausch Verhältnis for der verschiedenen vaskulären Strukturen bestimmt und zwischen den Feldstärken verglichen. Ergebnis: Beide Methoden zeigten the gleichen kleinen arteriellen Zweige oberhald des Circulus Willisii. Neben den Ästen erster Ordnung wurden auch sekundäre und tertiäre Äste dargestellt. PCMRAs zeigten die bessere Hintergrundunterdrückung. Im Vergleich zu den klilnischen 1,5T/3T Bildern, zeigte die MRA der Gehirnvaskulatur bei 7T höheren Gefäßkontrast und -schärfe. Ultrahochfeld MRAs demonstriertÄste höherer Ordnung mit kleiner Kalibern im Vergleich zur konventionellen MRA. Schlussfolgerung: Diese Studie zeigt die Möglichkeit TOF and PCMRA der Darstellung der arteriellen Gehringefäße bei 7T in einem Ganzkörper MR Tomographen. Es zeigte sich ein verbesserter Kontrast und eine verbesserte Darstellung im Vergleich zu den niedrigeren Feldstärken. 7T MRA wird ein wichtiges Werkzeug für die neuroradiologische Forschung darstellen. Korrespondierender Autor: Heverhagen T Klinikum der Philipps Universität, Klinik für Strahlendiagnostik, Baldingerstr., 35033 Marburg E-Mail: [email protected]
- 1 April 2009
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 181 (S 01) , WI_PO43
Time-of-Flight und Phase Contrast Magnetresonanzangiographie der intrazerebralen Arterien im Ultrahochfeld
Ziele: Ziel dieser Studie war es die Möglichkeit der Time-of-Flight (ToF) und Phase Contrast (PC) Magnetresonanzangiographie (MRA) der intrazerebralen Arterien im Ultrahochfeld 7T Magnetresonanztomographen zu untersuchen und der Vergleich mit konventionellen 1,5T und 3T Systemen. Methode: PC und TOF MRAs wurden in einem 7T MR Tomographen (Achieva, Philips) und in klinischen 3T (Achieva, Philips) and 1.5T (Signa, GE) Tomographen mit Birdcage-Kopfspulen akquiriert. 3D PC (TR:8–15ms; TE:3–4ms; FA:12–20°; FoV: 240mm; Matrix:512×384) und 3D TOF (TR:15–25ms; TE:3–4ms; FA:18–20°; FoV:240mm; Matrix:512×384) Sequenzen mit einer Schichtdicke von 0,75mm wurden in der transversalen Ebene aufgenommen. Diese schlossen die gesamte Gefäßanatomie des Circulus Willisii ein. PC und TOF Bilder wurden in ähnlichen Akquisitionszeiten von 5 Minuten aufgenommen. Die Darstellung der distalen Zweige cerebralen Arterien wurde ausgewertet. Zusätzlich wurde die Signal zu Rausch Verhältnis for der verschiedenen vaskulären Strukturen bestimmt und zwischen den Feldstärken verglichen. Ergebnis: Beide Methoden zeigten the gleichen kleinen arteriellen Zweige oberhald des Circulus Willisii. Neben den Ästen erster Ordnung wurden auch sekundäre und tertiäre Äste dargestellt. PCMRAs zeigten die bessere Hintergrundunterdrückung. Im Vergleich zu den klilnischen 1,5T/3T Bildern, zeigte die MRA der Gehirnvaskulatur bei 7T höheren Gefäßkontrast und -schärfe. Ultrahochfeld MRAs demonstriertÄste höherer Ordnung mit kleiner Kalibern im Vergleich zur konventionellen MRA. Schlussfolgerung: Diese Studie zeigt die Möglichkeit TOF and PCMRA der Darstellung der arteriellen Gehringefäße bei 7T in einem Ganzkörper MR Tomographen. Es zeigte sich ein verbesserter Kontrast und eine verbesserte Darstellung im Vergleich zu den niedrigeren Feldstärken. 7T MRA wird ein wichtiges Werkzeug für die neuroradiologische Forschung darstellen. Korrespondierender Autor: Heverhagen T Klinikum der Philipps Universität, Klinik für Strahlendiagnostik, Baldingerstr., 35033 Marburg E-Mail: [email protected]
- 1 February 2009
- Published by Bentham Science Publishers Ltd. in Current Nanoscience
- Vol. 5 (1) , 88-102
Nanoparticulate Iron Oxide Contrast Agents for Untargeted and Targeted Cardiovascular Magnetic Resonance Imaging
In cardiology and oncology, early disease detection produces better patient outcomes. Imaging approaches, particularly Magnetic Resonance Imaging (MRI), are attractive for screening large, mostly disease-free populations because they are noninvasive and produce high-resolution anatomical/morphological images from disease sites. Biochemically targeted nanoparticulate contrast agents (ultrasmall superparamagnetic iron oxide particles called USPIOs, superparamagnetic iron oxide nanoparticles called SPIONs, cross-linked iron oxides called CLIOs, Gadolinium chelates, and other superparamagnetic or paramagnetic particles) can be administered parenterally to define lesional biochemical/cellular composition, in addition to giving excellent definition of morphological features. Such targeted contrast agents can be considered modular nanobiological devices containing, at minimum, a contrast module and a targeting moiety. Here we review synthesis, surface chemistry and physics of superparamagnetic iron oxide MRI contrast agents (USPIOs and SPIONs) and results to date from the use of biochemically targeted and untargeted iron oxide MRI contrast agents in vivo, in vitro and ex vivo in vascular disease, and to a lesser extent, in oncology applications. We discuss design parameters critical to in vivo use of targeted contrast particles, including parameters influencing particle biodistribution/pharmacokinetics and immunogenicity. We discuss the increasing sophistication of theranostic contrast agents that provide other physiological services concurrent with their MRI function.
- 1 February 2009
- Published by Bentham Science Publishers Ltd. in Current Nanoscience
- Vol. 5 (1) , 88-102
Nanoparticulate Iron Oxide Contrast Agents for Untargeted and Targeted Cardiovascular Magnetic Resonance Imaging
In cardiology and oncology, early disease detection produces better patient outcomes. Imaging approaches, particularly Magnetic Resonance Imaging (MRI), are attractive for screening large, mostly disease-free populations because they are noninvasive and produce high-resolution anatomical/morphological images from disease sites. Biochemically targeted nanoparticulate contrast agents (ultrasmall superparamagnetic iron oxide particles called USPIOs, superparamagnetic iron oxide nanoparticles called SPIONs, cross-linked iron oxides called CLIOs, Gadolinium chelates, and other superparamagnetic or paramagnetic particles) can be administered parenterally to define lesional biochemical/cellular composition, in addition to giving excellent definition of morphological features. Such targeted contrast agents can be considered modular nanobiological devices containing, at minimum, a contrast module and a targeting moiety. Here we review synthesis, surface chemistry and physics of superparamagnetic iron oxide MRI contrast agents (USPIOs and SPIONs) and results to date from the use of biochemically targeted and untargeted iron oxide MRI contrast agents in vivo, in vitro and ex vivo in vascular disease, and to a lesser extent, in oncology applications. We discuss design parameters critical to in vivo use of targeted contrast particles, including parameters influencing particle biodistribution/pharmacokinetics and immunogenicity. We discuss the increasing sophistication of theranostic contrast agents that provide other physiological services concurrent with their MRI function.
- Open Access
- 9 May 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (6) , 1390-1395
Blipped multi gradient-echo slice excitation profile imaging (bmGESEPI) for fastT2* measurements with macroscopicB0 inhomogeneity compensation
- 9 May 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (6) , 1390-1395
Open AccessBlipped multi gradient-echo slice excitation profile imaging (bmGESEPI) for fastT2* measurements with macroscopicB0 inhomogeneity compensation
- 1 October 2003
- Vol. 24 (9) , 1881-1884
MR Imaging Visualization of the Cerebral Microvasculature: A Comparison of Live and Postmortem Studies at 8 T
Summary: In this study, we compared 8-T gradient-echo MR images of the microvasculature in the live human brain with images of the unembalmed and embalmed postmortem brain. Small vessels were well visualized in the live brain and even better seen in the unembalmed postmortem brain, but they could not be visualized in the embalmed postmortem brain. These findings are important for direct comparisons of the microvasculature on 8-T MR images and on histologic sections.
- 1 October 2003
- Vol. 24 (9) , 1881-1884
MR Imaging Visualization of the Cerebral Microvasculature: A Comparison of Live and Postmortem Studies at 8 T
Summary: In this study, we compared 8-T gradient-echo MR images of the microvasculature in the live human brain with images of the unembalmed and embalmed postmortem brain. Small vessels were well visualized in the live brain and even better seen in the unembalmed postmortem brain, but they could not be visualized in the embalmed postmortem brain. These findings are important for direct comparisons of the microvasculature on 8-T MR images and on histologic sections.