Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry
Authors:
- 30 March 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (4) , 1893-1903
Abstract
In this article, the image quality of reconstructed volumes by four algorithms for digital tomosynthesis, applied in the case of breast, is investigated using synchrotron radiation.An angular data set of 21 images of a complex phantom with heterogeneous tissue-mimicking background was obtained using the SYRMEP beamline at ELETTRA Synchrotron Light Laboratory, Trieste, Italy. The irradiated part was reconstructed using the multiple projection algorithm (MPA) and the filtered backprojection with ramp followed by hamming windows (FBR-RH) and filtered backprojection with ramp (FBP-R). Additionally, an algorithm for reducing the noise in reconstructed planes based on noise mask subtraction from the planes of the originally reconstructed volume using MPA (MPA-NM) has been further developed. The reconstruction techniques were evaluated in terms of calculations and comparison of the contrast-to-noise ratio (CNR) and artifact spread function.It was found that the MPA-NM resulted in higher CNR, comparable with the CNR of FBP-RH for high contrast details. Low contrast objects are well visualized and characterized by high CNR using the simple MPA and the MPA-NM. In addition, the image quality of the reconstructed features in terms of CNR and visual appearance as a function of the initial number of projection images and the reconstruction arc was carried out. Slices reconstructed with more input projection images result in less reconstruction artifacts and higher detail CNR, while those reconstructed from projection images acquired in reduced angular range causes pronounced streak artifacts.Of the reconstruction algorithms implemented, the MPA-NM and MPA are a good choice for detecting low contrast objects, while the FBP-RH, FBP-R, and MPA-NM provide high CNR and well outlined edges in case of microcalcifications.Keywords
Funding Information
- (ESF)/Operational Program of Educational and Vocational Training II (EPEAEK II)
- Program PYTHAGORAS I
This publication has 25 references indexed in Scilit:
- Optimization of Tomosynthesis Acquisition Parameters: Angular Range and Number of Projections2008
- Digital Breast Tomosynthesis: Initial Experience in 98 Women with Abnormal Digital Screening MammographyAmerican Journal of Roentgenology, 2007
- A comparative study of limited‐angle cone‐beam reconstruction methods for breast tomosynthesisMedical Physics, 2006
- A comparison of reconstruction algorithms for C-arm mammography tomosynthesisMedical Physics, 2006
- A comparison of reconstruction algorithms for breast tomosynthesisMedical Physics, 2004
- Circular Tomosynthesis: Potential in Imaging of Breast and Upper Cervical Spine—Preliminary Phantom and in Vitro StudyRadiology, 2003
- Tomographic mammography using a limited number of low‐dose cone‐beam projection imagesMedical Physics, 2003
- Digital tomosynthesis in breast imaging.Radiology, 1997
- Mammography with synchrotron radiation.Radiology, 1995
- A method for selective removal of out‐of‐plane structures in digital tomosynthesisMedical Physics, 1993