Sub-microradian angular detection limits for field mapping by Lorentz 4D scanning transmission electron microscopy on a Si p–n junction
Open Access
- 8 September 2025
- journal article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (10)
Abstract
We have examined a focused ion beam prepared silicon p–n junction lamella with different thicknesses by Lorentz 4D scanning transmission electron microscopy using center-of-mass (CoM) analysis. Using convergence semi-angles of 992, 207, and 83 μrad, we demonstrate diffraction limited spatial resolution combined with deflection detection limits on the sample as good as 0.49 μrad. We assess electron beam deflection detection limits away from the p–n junction, as well as the variation along the junction, and compare these with the variation in a vacuum region. With the larger semi-convergence angle of 992 μrad, a rigid shift of the transmitted disk was observed in the junction, while using smaller angles, a redistribution of intensity in the transmitted beam occurs, leading to an underestimation of the electric field related to the larger electron probe size. It is shown that electric field detection limits as good as 0.033, 0.0072, and 0.0051 MV cm−1 could be obtained for decreasing semi-convergence angles (at 376 nm sample thickness), equivalent to angular detection limits of 3.2, 0.68, and 0.49 μrad, respectively. For an optimal detection limit, we show that about 50 counts per pixel within the diffracted disk are needed for all settings, allowing rapid acquisition of diffraction maps, mitigating sample drift and beam damage issues. Moreover, we demonstrate that the CoM shift increases linearly with electrically active sample thickness, as must be the case for a quantitative signal.Keywords
Funding Information
- HORIZON EUROPE European Research Council (758385)
- Agence Nationale de la Recherche (ANR-22-PEXD-0013)
- European Regional Development Fund (RA0023813)
This publication has 28 references indexed in Scilit:
- Measuring electrical properties in semiconductor devices by pixelated STEM and off-axis electron holography (or convergent beams vs. plane waves).Micron, 2024
- Measuring Spatially‐Resolved Potential Drops at Semiconductor Hetero‐Interfaces Using 4D‐STEMSmall Methods, 2023
- The differential phase contrast uncertainty relation: Connection between electron dose and field resolutionUltramicroscopy, 2021
- 4D-STEM at interfaces to GaN: Centre-of-mass approach & NBED-disc detectionUltramicroscopy, 2021
- Quantitative electric field mapping of a p–n junction by DPC STEMUltramicroscopy, 2020
- Direct comparison of off-axis holography and differential phase contrast for the mapping of electric fields in semiconductors by transmission electron microscopy.Ultramicroscopy, 2019
- Measurement of atomic electric fields and charge densities from average momentum transfers using scanning transmission electron microscopyUltramicroscopy, 2017
- On detector linearity and precision of beam shift detection for quantitative differential phase contrast applicationsUltramicroscopy, 2016
- Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performanceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011