No differences in knee kinematics between active and passive flexion‐extension movement: an intra‐operative kinematic analysis performed during total knee arthroplasty
Authors:
- Alberto GrassiAGAlberto Grassi
- Nicola PizzaNPNicola Pizza
- Nicola Francesco LopomoNicola Francesco Lopomo
- Maurilio MarcacciMMMaurilio Marcacci
- Michele CapozziMCMichele Capozzi
- Giulio Maria Marcheggiani MuccioliGMGiulio Maria Marcheggiani Muccioli
- Francesca ColleFCFrancesca Colle
- Stefano ZaffagniniSZStefano Zaffagnini
Open Access
- 1 January 2020
- journal article
- research article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 7 (1) , 1-8
Abstract
Purpose: The objective of the present study was to acquire and compare by the use of a navigation system the intra‐operative flexion‐extension movement of the knee performed actively by the patient and passively by the surgeon before and after a total knee arthroplasty (TKA) implantation.Methods: A cohort of 31 patients with primary knee osteoarthritis (OA), candidate for TKA underwent intra‐operative kinematics assessment with a commercial navigation system before and after the definitive implant positioning of a Cruciate Retaining (CR) Mobile Bearing (MB) prostheses. The kinematical data were acquired while surgeon performed the flexion‐extension movement (passive ROM ‐ pROM), and while the patient performed it (active ROM ‐ aROM). Differences between pre‐ and post‐ implantation and between active and passive motions, were statistically analyzed using paired Student t‐tests (p = 0.05).Results: No statistically significant difference were found between aROM and pROM with paired Student t‐test regarding internal‐external rotation and anterior‐posterior translation of the femoral component with respect to the tibia during flexion‐extension movement before and after TKA implant (p > 0.05).Conclusions: Active muscle contraction seems to not significantly affect TKA kinematics. The ROM performed by the surgeon during operation resemble the movement actively performed by the patient.The clinical relevance of this study further supports the use of CAS system in performing intra‐operative analysis concerning knee biomechanics.Keywords
This publication has 22 references indexed in Scilit:
- Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2015
- Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile‐bearing total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2015
- Navigation‐based femorotibial rotation pattern correlated with flexion angle after total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2014
- Three different cruciate‐sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differencesKnee Surgery, Sports Traumatology, Arthroscopy, 2014
- Deep‐dished highly congruent tibial insert in CR‐TKA does not prevent patellar tendon angle increase and patellar anterior translationKnee Surgery, Sports Traumatology, Arthroscopy, 2014
- Correlation between preoperative and postoperative knee kinematics in total knee arthroplasty using cruciate retaining designsInternational Orthopaedics, 2010
- Assessment of tibiofemoral position in total knee arthroplasty using the active flexion lateral radiographThe Knee, 2010
- The Reproducibility of a Kinematically-Derived Axis of the Knee versus Digitized Anatomical Landmarks using a Knee Navigation SystemThe Open Biomedical Engineering Journal, 2008
- Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstructionClinical Biomechanics, 2006
- Application of the Joint Coordinate System to Three-Dimensional Joint Attitude and Movement Representation: A Standardization ProposalJournal of Biomechanical Engineering, 1993