Abstract
O the position of the scapula. The purpose of this study was to investigate the effect of scapular rotation in the coronal and sagittal planes on glenoid version as measured on two-dimensional images. Methods: Computer-generated three-dimensional models of scapulae from computed tomography scans of thirty-six shoulders in whole-body cadavers were generated. The anatomic geometry of these models had been previously validated. The position of the scapulae relative to the gantry was determined. The three-dimensional models were rotated in 1° increments in the coronal and sagittal planes. Glenoid version was measured on two-dimensional images for each of the rotation increments. Version variability at each rotation increment was calculated. Results: The anatomic glenoid version (independent of the resting position of the scapula) was an average (and standard deviation) of 2.0° ± 3.8° of retroversion. The average difference between anatomic glenoid version and clinical glenoid version (depending on the position of the scapula on the original computed tomography axial images) was 6.9° ± 5.6° (range, 0.1° to 22.5°). Version variability with coronal or sagittal rotation was significant for all degrees of rotation (p < 0.0001). Scapular abduction had the greatest effect on version variation and resulted in 0.42° of relative anteversion for every 1° of abduction in the coronal plane. In the sagittal plane, internal rotation resulted in relative anteversion. Conclusions: Any malalignment of ≥1° of the scapula in the coronal or sagittal plane will create inaccuracies in measuring glenoid version. The plane of axial reconstruction should be aligned with the scapula when two-dimensional computed tomography images are used to measure glenoid version. These findings support the use of three-dimensional models to evaluate glenoid version. Clinical Relevance: When computed tomography scans are made to evaluate glenoid version, the plane of axial reconstruction must be taken into account. In contrast, glenoid version measured on three-dimensional models is independent of scapular position....Keywords
This publication has 22 references indexed in Scilit:
- Motion of the Shoulder Complex During Multiplanar Humeral ElevationJournal of Bone and Joint Surgery, 2009
- Validation of three-dimensional models of in situ scapulaeJournal of Shoulder and Elbow Surgery, 2008
- The three-dimensional glenoid vault model can estimate normal glenoid version in osteoarthritisJournal of Shoulder and Elbow Surgery, 2008
- Biomechanical effects of glenoid retroversion in total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2007
- Effects of glenoid component version on humeral head displacement and joint reaction forces: An experimental studyJournal of Shoulder and Elbow Surgery, 2006
- Risks of loosening of a prosthetic glenoid implanted in retroversionJournal of Shoulder and Elbow Surgery, 2006
- The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2004
- Measurement of glenoid version: conventional radiographs versus computed tomography scansJournal of Shoulder and Elbow Surgery, 2003
- Humeroscapular positions in a shoulder range-of-motion-examinationJournal of Shoulder and Elbow Surgery, 1992
- Variations in human scapulaeAmerican Journal of Physical Anthropology, 1942