Absolute linear-in-k spectrometer designs enabled by freeform optics
- 11 November 2019
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (24) , 34593-34602
Abstract
Linear-in-wavenumber, k, spectrometers have the merits of saving signal processing time and improving the sensitivity of spectral-domain optical coherence tomography (SD-OCT) by avoiding post-k-interpolation. We report on an approach leveraging freeform optics to linearize spectrometers in k to achieve an extremely low residual k-nonlinearity in design. A freeform lens reduced the k-nonlinearity from 2.47% for a benchmark spectrometer to 2.79 × 10−5% and 3.36 × 10−9% using the Fringe Zernike coefficients up to the 16th term and 37th term, respectively. A simulation model was developed to evaluate the performance of SD-OCT with the designed spectrometers. Without the k-interpolation in software, results show that the two freeform spectrometers achieve a roll-off gain of 5.24 dB over the imaging depth from 0.5 to 5.5 mm, while the maximum imaging depth is 5.8 mm. Finally, a 4.2-µm-FWHM axial PSF was maintained throughout the imaging depth in air.Keywords
Funding Information
- University of Rochester
- Empire State Development's Division of Science, Technology and Innovation (C160189)
- Empire State Development (C150130)
This publication has 16 references indexed in Scilit:
- Design of a freeform electronic viewfinder coupled to aberration fields of freeform opticsOptics Express, 2015
- Ultrahigh-Resolution Spectral Domain Optical Coherence Tomography Based on a Linear-Wavenumber SpectrometerJournal of the Optical Society of Korea, 2015
- Theory of aberration fields for general optical systems with freeform surfacesOptics Express, 2014
- Broadband astigmatism-corrected Czerny–Turner spectrometerOptics Express, 2010
- Experimental validation of an optimized signal processing method to handle non-linearity in swept-source optical coherence tomographyOptics Express, 2010
- Real-time display on Fourier domain optical coherence tomography system using a graphics processing unitJournal of Biomedical Optics, 2009
- Linear-wavenumber spectrometer for high-speed spectral-domain optical coherence tomographyOptics and Spectroscopy, 2009
- Fourier domain optical coherence tomography with a linear-in-wavenumber spectrometerOptics Letters, 2007
- Spectral resolution and sampling issues in Fourier-transform spectral interferometryJournal of the Optical Society of America B, 2000