Di Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Di Xu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Jannick P. Rolland
The Institute of Optics, University of Rochester, Rochester, NY 14620, USA
7 shared publicationsJacob Reimers
The Institute of Optics, University of Rochester, Rochester, NY 14620, USA
3 shared publicationsJonathan C. Papa
The Institute of Optics, University of Rochester, Rochester, NY 14620, USA
3 shared publicationsAndres Garcia Coleto
University of Rochester
2 shared publicationsJianing Yao
University of Rochester, United States
2 shared publicationsJoseph D. Owen
Dept. of Mechanical Engineering and Engineering Science, UNC Charlotte, Charlotte, NC 28223, USA
2 shared publications
Latest Publications
- Open Access
- 4 March 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (6) , 8542-8552
Verification of cascade optical coherence tomography for freeform optics form metrology
Freeform optical components enable dramatic advances for optical systems in both performance and packaging. Surface form metrology of manufactured freeform optics remains a challenge and an active area of research. Towards addressing this challenge, we previously reported on a novel architecture, cascade optical coherence tomography (C-OCT), which was validated for its ability of high-precision sag measurement at a given point. Here, we demonstrate freeform surface measurements, enabled by the development of a custom optical-relay-based scanning mechanism and a unique high-speed rotation mechanism. Experimental results on a flat mirror demonstrate an RMS flatness of 14 nm (∼λ/44 at the He-Ne wavelength). Measurement on a freeform mirror is achieved with an RMS residual of 69 nm (∼λ/9). The system-level investigations and validation provide the groundwork for advancing C-OCT as a viable freeform metrology technique.
- 4 March 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (6) , 8542-8552
Open AccessVerification of cascade optical coherence tomography for freeform optics form metrology
Freeform optical components enable dramatic advances for optical systems in both performance and packaging. Surface form metrology of manufactured freeform optics remains a challenge and an active area of research. Towards addressing this challenge, we previously reported on a novel architecture, cascade optical coherence tomography (C-OCT), which was validated for its ability of high-precision sag measurement at a given point. Here, we demonstrate freeform surface measurements, enabled by the development of a custom optical-relay-based scanning mechanism and a unique high-speed rotation mechanism. Experimental results on a flat mirror demonstrate an RMS flatness of 14 nm (∼λ/44 at the He-Ne wavelength). Measurement on a freeform mirror is achieved with an RMS residual of 69 nm (∼λ/9). The system-level investigations and validation provide the groundwork for advancing C-OCT as a viable freeform metrology technique.
- Open Access
- 22 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (14) , 19937-19953
Cascade optical coherence tomography (C-OCT)
Significant advances for optical systems in terms of both performance and packaging are enabled by freeform optical components. Yet, surface form metrology for freeform optics remains a challenge. We developed and investigated a point-cloud cascade optical coherence tomography (C-OCT) technique to address this metrology challenge. The mathematical framework for the working principle of C-OCT is presented. A novel detection scheme is developed to enable high-speed measurements. Experimental results validate the C-OCT technique with the prototype setup demonstrating single-point precision of ±26 nm (∼λ/24 at the He-Ne wavelength), paving the way towards full surface measurements on freeform optical components.
- 22 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (14) , 19937-19953
Open AccessCascade optical coherence tomography (C-OCT)
Significant advances for optical systems in terms of both performance and packaging are enabled by freeform optical components. Yet, surface form metrology for freeform optics remains a challenge. We developed and investigated a point-cloud cascade optical coherence tomography (C-OCT) technique to address this metrology challenge. The mathematical framework for the working principle of C-OCT is presented. A novel detection scheme is developed to enable high-speed measurements. Experimental results validate the C-OCT technique with the prototype setup demonstrating single-point precision of ±26 nm (∼λ/24 at the He-Ne wavelength), paving the way towards full surface measurements on freeform optical components.
- 11 November 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (24) , 34593-34602
Absolute linear-in-k spectrometer designs enabled by freeform optics
Linear-in-wavenumber, k, spectrometers have the merits of saving signal processing time and improving the sensitivity of spectral-domain optical coherence tomography (SD-OCT) by avoiding post-k-interpolation. We report on an approach leveraging freeform optics to linearize spectrometers in k to achieve an extremely low residual k-nonlinearity in design. A freeform lens reduced the k-nonlinearity from 2.47% for a benchmark spectrometer to 2.79 × 10−5% and 3.36 × 10−9% using the Fringe Zernike coefficients up to the 16th term and 37th term, respectively. A simulation model was developed to evaluate the performance of SD-OCT with the designed spectrometers. Without the k-interpolation in software, results show that the two freeform spectrometers achieve a roll-off gain of 5.24 dB over the imaging depth from 0.5 to 5.5 mm, while the maximum imaging depth is 5.8 mm. Finally, a 4.2-µm-FWHM axial PSF was maintained throughout the imaging depth in air.
- 11 November 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (24) , 34593-34602
Absolute linear-in-k spectrometer designs enabled by freeform optics
Linear-in-wavenumber, k, spectrometers have the merits of saving signal processing time and improving the sensitivity of spectral-domain optical coherence tomography (SD-OCT) by avoiding post-k-interpolation. We report on an approach leveraging freeform optics to linearize spectrometers in k to achieve an extremely low residual k-nonlinearity in design. A freeform lens reduced the k-nonlinearity from 2.47% for a benchmark spectrometer to 2.79 × 10−5% and 3.36 × 10−9% using the Fringe Zernike coefficients up to the 16th term and 37th term, respectively. A simulation model was developed to evaluate the performance of SD-OCT with the designed spectrometers. Without the k-interpolation in software, results show that the two freeform spectrometers achieve a roll-off gain of 5.24 dB over the imaging depth from 0.5 to 5.5 mm, while the maximum imaging depth is 5.8 mm. Finally, a 4.2-µm-FWHM axial PSF was maintained throughout the imaging depth in air.
- 20 February 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (5) , 6184-6200
Telecentric broadband objective lenses for optical coherence tomography (OCT) in the context of low uncertainty metrology of freeform optical components: from design to testing for wavefront and telecentricity
Freeform optical components enable significant advances for optical systems. A major challenge for freeform optics is the current lack of metrology methods with measurement uncertainty on the order of tens of nanometers or less. Towards addressing this challenge, optical coherence tomography (OCT) is a viable technique. In the context of low uncertainty metrology, the design requirements pertaining to the sample arm of an OCT metrology system are explicitly addressed in this paper. Two telecentric, broadband, diffraction limited, custom objective lens designs are presented with their design strategies. One objective lens was fabricated and experimentally tested for wavefront performance and telecentricity. This lens demonstrates near diffraction limited performance and a maximum deviation from telecentricity of 8.7 arcseconds across the full field of view, correlating to measurement uncertainty of less than 12 nm in simulation. The telecentricity test method developed completes the loop with respect to the design requirements and strategies presented and provides further intuition for telecentric lens designs in general.
- 20 February 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (5) , 6184-6200
Telecentric broadband objective lenses for optical coherence tomography (OCT) in the context of low uncertainty metrology of freeform optical components: from design to testing for wavefront and telecentricity
Freeform optical components enable significant advances for optical systems. A major challenge for freeform optics is the current lack of metrology methods with measurement uncertainty on the order of tens of nanometers or less. Towards addressing this challenge, optical coherence tomography (OCT) is a viable technique. In the context of low uncertainty metrology, the design requirements pertaining to the sample arm of an OCT metrology system are explicitly addressed in this paper. Two telecentric, broadband, diffraction limited, custom objective lens designs are presented with their design strategies. One objective lens was fabricated and experimentally tested for wavefront performance and telecentricity. This lens demonstrates near diffraction limited performance and a maximum deviation from telecentricity of 8.7 arcseconds across the full field of view, correlating to measurement uncertainty of less than 12 nm in simulation. The telecentricity test method developed completes the loop with respect to the design requirements and strategies presented and provides further intuition for telecentric lens designs in general.
- Open Access
- 22 June 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (13) , 15252-15268
Design, fabrication, and testing of convex reflective diffraction gratings
The convex reflective diffraction grating is an essential optical component that lends itself to various applications. In this work, we first outline the design principles of convex diffraction gratings from wavefront quality and efficiency perspectives. We then describe a unique fabrication method that allows for the machining of convex diffraction gratings with variable groove structure, which is extendable to rotationally non-symmetric convex diffraction grating substrates. Finally, we demonstrate two quantitative wavefront measurement methods and respective experimental validation.
- 22 June 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (13) , 15252-15268
Open AccessDesign, fabrication, and testing of convex reflective diffraction gratings
The convex reflective diffraction grating is an essential optical component that lends itself to various applications. In this work, we first outline the design principles of convex diffraction gratings from wavefront quality and efficiency perspectives. We then describe a unique fabrication method that allows for the machining of convex diffraction gratings with variable groove structure, which is extendable to rotationally non-symmetric convex diffraction grating substrates. Finally, we demonstrate two quantitative wavefront measurement methods and respective experimental validation.
- 1 January 2017
- Published by Optica Publishing Group
- p. OM2B.3
Testing of a Convex Reflective Diffraction Grating
A quantitative nulling interferometric measurement technique for wavefront fidelity validation of a blazed convex reflective diffraction grating is presented. A null wavefront of λ/45 RMS at wavelength 633 nm is demonstrated.
- 1 January 2017
- Published by Optica Publishing Group
- p. OM2B.3
Testing of a Convex Reflective Diffraction Grating
A quantitative nulling interferometric measurement technique for wavefront fidelity validation of a blazed convex reflective diffraction grating is presented. A null wavefront of λ/45 RMS at wavelength 633 nm is demonstrated.
- 1 January 2016
- Published by Optica Publishing Group
- p. FW5H.6
Scanning Customized Swept-source Optical Coherence Tomography (SS-OCT) for the Metrology of Freeform Optical Surfaces
A high-precision SS-OCT system with custom scanning configuration was developed for the point cloud metrology of freeform optical surfaces. Capabilities were demonstrated on an Alvarez surface and a measurement precision of λ/20 was achieved.
- 1 January 2016
- Published by Optica Publishing Group
- p. FW5H.6
Scanning Customized Swept-source Optical Coherence Tomography (SS-OCT) for the Metrology of Freeform Optical Surfaces
A high-precision SS-OCT system with custom scanning configuration was developed for the point cloud metrology of freeform optical surfaces. Capabilities were demonstrated on an Alvarez surface and a measurement precision of λ/20 was achieved.
- 11 October 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9633, 96331A-96331A-5
Freeform metrology using swept-source optical coherence tomography with custom pupil-relay precision scanning configuration
- 11 October 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9633, 96331A-96331A-5
Freeform metrology using swept-source optical coherence tomography with custom pupil-relay precision scanning configuration
- 3 September 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9580, 95800L-95800L-8
Design study for a 16x zoom lens system for visible surveillance camera
- 3 September 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9580, 95800L-95800L-8
Design study for a 16x zoom lens system for visible surveillance camera