Optimising 7T-fMRI for imaging regions of magnetic susceptibility
Preprint
Abstract
The temporal signal-to-noise ratio (tSNR) of functional magnetic resonance imaging (fMRI) is particularly poor in ventral anterior temporal and orbitofrontal regions because of B 0 and B 1 + magnetic field inhomogeneity, a problem that is exacerbated at higher field strengths. In this 7T-fMRI study we compared three methods of improving sensitivity in these areas: parallel transmit, which uses multiple transmit elements, controlled independently, to homogenise the flip angle experienced by the tissue; multi-echo, which entails collection of multiple volumes at different echo times following a single radiofrequency pulse; and multiband, in which multiple slices are acquired simultaneously. We found that parallel transmit and multi-echo increased the magnitude of the BOLD signal change, but only multi-echo increased BOLD magnitude in areas prone to susceptibility artefacts. Multiband and denoising of multi-echo data with independent components analysis (ICA) both improved precision of GLM fit. Exploratory results suggested that multi-echo and ICA denoising can both benefit multivariate analyses. In conclusion, a multi-echo, multiband sequence improved fMRI quality in areas prone to susceptibility artefacts while maintaining sensitivity across the whole brain. We recommend this approach for studies investigating the functional roles of ventral temporal and orbitofrontal regions with 7T fMRI.Keywords
Funding Information
- Medical Research Council Canada (SUAG/019 G116768)
- Medical Research Council Canada (MR N013433-1)
- Medical Research Council Canada (MR/R023883/1)
- Medical Research Council Canada (MC_UU_00005/18)
- Medical Research Council Canada (MR/V031481/1)
- Medical Research Council Canada (MR/M008983/1)
This publication has 90 references indexed in Scilit:
- Contribution of the multi‐echo approach in accelerated functional magnetic resonance imaging multiband acquisitionHuman Brain Mapping, 2021
- A comparison of dual gradient‐echo and spin‐echo fMRI of the inferior temporal lobeHuman Brain Mapping, 2014
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- Distortion correction for diffusion‐weighted MRI tractography and fMRI in the temporal lobesHuman Brain Mapping, 2010
- BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: Parallel‐acquired inhomogeneity‐desensitized fMRIMagnetic Resonance in Medicine, 2006
- Variable‐rate selective excitation for rapid MRI sequencesMagnetic Resonance in Medicine, 2004
- Real‐time quantification of T changes using multiecho planar imaging and numerical methodsMagnetic Resonance in Medicine, 2002
- Fast robust automated brain extractionHuman Brain Mapping, 2002
- Software tools for analysis and visualization of fMRI dataNMR in Biomedicine, 1997