Minghao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Minghao Zhang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Christopher T. Rodgers
Department of Clinical Neurosciences University of Cambridge Cambridge UK
6 shared publications - Ajay D. Halai
Medical Research Council; Cognition and Brain Sciences Unit, University of Cambridge , 15 Chaucer Road, Cambridge CB2 7EF
2 shared publications Iulius Dragonu
Siemens Healthcare Ltd, Frimley, United Kingdom
2 shared publications- Marta Morgado Correia
University of Cambridge
2 shared publications - Matthew A. Lambon Ralph
University of Cambridge
2 shared publications - Saskia L. Frisby
MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK
2 shared publications
Latest Publications
- Open Access
- 10 August 2026
- Published by Wiley in Human Brain Mapping
- Vol. 47 (11)
Optimising 7T ‐ fMRI for Imaging Regions of Magnetic Susceptibility
The temporal signal‐to‐noise ratio (tSNR) of functional magnetic resonance imaging (fMRI) is particularly poor in ventral anterior temporal and orbitofrontal regions because of B 0 and B 1 + magnetic field inhomogeneity, a problem that is exacerbated at higher field strengths. In this 7T‐fMRI study we compared three methods of improving sensitivity in these areas: parallel transmit, which uses multiple transmit elements, controlled independently, to homogenise the flip angle experienced by the tissue; multi‐echo, which entails collection of multiple volumes at different echo times following a single radiofrequency pulse; and multiband, in which multiple slices are acquired simultaneously. We found that parallel transmit and multi‐echo increased the magnitude of the BOLD signal change, but only multi‐echo increased BOLD magnitude in areas prone to susceptibility artefacts. Multiband and denoising of multi‐echo data with independent components analysis (ICA) both improved precision of GLM fit. Exploratory results suggested that multi‐echo and ICA denoising can both benefit multivariate analyses. In conclusion, a multi‐echo, multiband sequence improved fMRI quality in areas prone to susceptibility artefacts while maintaining sensitivity across the whole brain. We recommend this approach for studies investigating the functional roles of ventral temporal and orbitofrontal regions with 7T fMRI.
- 10 August 2026
- Published by Wiley in Human Brain Mapping
- Vol. 47 (11)
Open AccessOptimising 7T ‐ fMRI for Imaging Regions of Magnetic Susceptibility
The temporal signal‐to‐noise ratio (tSNR) of functional magnetic resonance imaging (fMRI) is particularly poor in ventral anterior temporal and orbitofrontal regions because of B 0 and B 1 + magnetic field inhomogeneity, a problem that is exacerbated at higher field strengths. In this 7T‐fMRI study we compared three methods of improving sensitivity in these areas: parallel transmit, which uses multiple transmit elements, controlled independently, to homogenise the flip angle experienced by the tissue; multi‐echo, which entails collection of multiple volumes at different echo times following a single radiofrequency pulse; and multiband, in which multiple slices are acquired simultaneously. We found that parallel transmit and multi‐echo increased the magnitude of the BOLD signal change, but only multi‐echo increased BOLD magnitude in areas prone to susceptibility artefacts. Multiband and denoising of multi‐echo data with independent components analysis (ICA) both improved precision of GLM fit. Exploratory results suggested that multi‐echo and ICA denoising can both benefit multivariate analyses. In conclusion, a multi‐echo, multiband sequence improved fMRI quality in areas prone to susceptibility artefacts while maintaining sensitivity across the whole brain. We recommend this approach for studies investigating the functional roles of ventral temporal and orbitofrontal regions with 7T fMRI.
- Open Access
- 23 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3077-3094
Absolute Quantification of Brain Deuterium Metabolic Imaging in Healthy Volunteers and Glioblastoma Patients at 7T
Purpose: We present a method for absolute quantification of deuterated metabolites in vivo at 7T. We describe acquisition protocols and an analysis pipeline compatible with 7T Terra MRIs. We apply them using a 2 H/ 1 H receive array in healthy volunteers and glioblastoma patients. Methods: B 1 + /B 1 − maps from multiple CSI scans in a uniform phantom were used to derive calibrated coil weights for absolute quantification. We validated this in phantoms with known deuterated compounds. 2 H MRSI was performed in twelve healthy volunteers (two post‐[6,6‐ 2 H 2 ]‐glucose) and five treatment‐naive glioblastoma patients (all post‐[6,6‐ 2 H 2 ]‐glucose). Spectra were fitted with OXSA. We compared Glx/Lac between tumor and normal‐appearing brain using linear mixed‐effects models. Results: Measured B 1 + maps were 0.82 ± 0.19 μT/√W across the whole phantom. Natural abundance deuterium in water was 8.96 ± 0.7 mmol/L. Absolute maps of HDO, Glc, Glx, and Lac were acquired following [6,6‐ 2 H 2 ]glucose. Rate maps showed higher Lac production in tumors (2.3 μmol/L/min, SE = 0.87) compared with normal‐appearing regions (1.0 μmol/L/min, SE = 0.36; p < 0.01) and healthy brain (0.5 μmol/L/min, SE = 0.17; p < 0.01). Glx production was lower in tumors (3.8 μmol/L/min, SE = 0.44) relative to normal‐appearing contralateral regions (6.0 μmol/L/min, SE = 0.36; p < 0.001) and healthy brain (9.2 μmol/L/min, SE = 0.61; p < 0.001). Conclusion: We demonstrate robust absolute quantification for human 7T DMI. Glioblastoma tumors showed elevated Lac and reduced Glx labeling relative to normal brain, with inter‐patient heterogeneity consistent with an existence of different metabolic subtypes.
- 23 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3077-3094
Open AccessAbsolute Quantification of Brain Deuterium Metabolic Imaging in Healthy Volunteers and Glioblastoma Patients at 7T
Purpose: We present a method for absolute quantification of deuterated metabolites in vivo at 7T. We describe acquisition protocols and an analysis pipeline compatible with 7T Terra MRIs. We apply them using a 2 H/ 1 H receive array in healthy volunteers and glioblastoma patients. Methods: B 1 + /B 1 − maps from multiple CSI scans in a uniform phantom were used to derive calibrated coil weights for absolute quantification. We validated this in phantoms with known deuterated compounds. 2 H MRSI was performed in twelve healthy volunteers (two post‐[6,6‐ 2 H 2 ]‐glucose) and five treatment‐naive glioblastoma patients (all post‐[6,6‐ 2 H 2 ]‐glucose). Spectra were fitted with OXSA. We compared Glx/Lac between tumor and normal‐appearing brain using linear mixed‐effects models. Results: Measured B 1 + maps were 0.82 ± 0.19 μT/√W across the whole phantom. Natural abundance deuterium in water was 8.96 ± 0.7 mmol/L. Absolute maps of HDO, Glc, Glx, and Lac were acquired following [6,6‐ 2 H 2 ]glucose. Rate maps showed higher Lac production in tumors (2.3 μmol/L/min, SE = 0.87) compared with normal‐appearing regions (1.0 μmol/L/min, SE = 0.36; p < 0.01) and healthy brain (0.5 μmol/L/min, SE = 0.17; p < 0.01). Glx production was lower in tumors (3.8 μmol/L/min, SE = 0.44) relative to normal‐appearing contralateral regions (6.0 μmol/L/min, SE = 0.36; p < 0.001) and healthy brain (9.2 μmol/L/min, SE = 0.61; p < 0.001). Conclusion: We demonstrate robust absolute quantification for human 7T DMI. Glioblastoma tumors showed elevated Lac and reduced Glx labeling relative to normal brain, with inter‐patient heterogeneity consistent with an existence of different metabolic subtypes.
- Open Access
- 29 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 740-755
Scalable spokes pTx pulses for 2D turbo‐spin‐echo imaging at 7 T
Purpose: Turbo spin echo (TSE) is important clinically. Unfortunately, 7 T TSE suffers from B 1 + ‐induced signal dropouts. Magnitude‐based parallel transmit (pTx) pulse design algorithms cannot enforce phase patterns complying with the Carr‐Purcell‐Meiboom‐Gill conditions (90° phase shift between excitation and refocusing). We introduce scalable spokes pTx pulses for 7 T TSE imaging. Theory: We define scalable spokes pulses as having time‐symmetric RF waveforms, antisymmetric in‐plane gradients, and rephased subpulse slice‐selection gradients. They produce flip angles that are approximately proportional to the applied voltage with voltage‐independent phase patterns. Methods: Scalable spokes pulses were designed for a phantom. Scaling behavior was characterized via Bloch simulations. Performance in terms of TSE echo homogeneity was assessed by extended phase graph simulations using in vivo field maps. Performance was validated for TSE acquisitions in a phantom and in vivo. Hippocampal TSE imaging was performed for four subjects comparing circularly polarized (CP), RF shimming, and scalable spokes pulses. Results: Scalable spokes pTx pulses show similar scaling behavior to previously proposed 3D k T ‐point pulses. Scalable three‐spoke pulses decrease flip‐angle RMS error across subjects compared to CP mode pulses (11% vs. 23% for 120° pulses). TSE images with these pulses recover signals in cerebellum and temporal lobes. Conclusion: Scalable spokes pTx pulses produce flip angles that vary approximately linearly with peak voltage while maintaining consistent spatial patterns of phase. Together with their spatial flip‐angle homogeneity, these pulses enable high‐fidelity 2D slice‐by‐slice TSE imaging at 7 T, albeit with reduced slice coverage with our choice of homogeneity target under the current vendor‐provided specific absorption rate constraints on 7 T MRI scanners.
- 29 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 740-755
Open AccessScalable spokes pTx pulses for 2D turbo‐spin‐echo imaging at 7 T
Purpose: Turbo spin echo (TSE) is important clinically. Unfortunately, 7 T TSE suffers from B 1 + ‐induced signal dropouts. Magnitude‐based parallel transmit (pTx) pulse design algorithms cannot enforce phase patterns complying with the Carr‐Purcell‐Meiboom‐Gill conditions (90° phase shift between excitation and refocusing). We introduce scalable spokes pTx pulses for 7 T TSE imaging. Theory: We define scalable spokes pulses as having time‐symmetric RF waveforms, antisymmetric in‐plane gradients, and rephased subpulse slice‐selection gradients. They produce flip angles that are approximately proportional to the applied voltage with voltage‐independent phase patterns. Methods: Scalable spokes pulses were designed for a phantom. Scaling behavior was characterized via Bloch simulations. Performance in terms of TSE echo homogeneity was assessed by extended phase graph simulations using in vivo field maps. Performance was validated for TSE acquisitions in a phantom and in vivo. Hippocampal TSE imaging was performed for four subjects comparing circularly polarized (CP), RF shimming, and scalable spokes pulses. Results: Scalable spokes pTx pulses show similar scaling behavior to previously proposed 3D k T ‐point pulses. Scalable three‐spoke pulses decrease flip‐angle RMS error across subjects compared to CP mode pulses (11% vs. 23% for 120° pulses). TSE images with these pulses recover signals in cerebellum and temporal lobes. Conclusion: Scalable spokes pTx pulses produce flip angles that vary approximately linearly with peak voltage while maintaining consistent spatial patterns of phase. Together with their spatial flip‐angle homogeneity, these pulses enable high‐fidelity 2D slice‐by‐slice TSE imaging at 7 T, albeit with reduced slice coverage with our choice of homogeneity target under the current vendor‐provided specific absorption rate constraints on 7 T MRI scanners.
- Open Access
Optimising 7T-fMRI for imaging regions of magnetic susceptibility
The temporal signal-to-noise ratio (tSNR) of functional magnetic resonance imaging (fMRI) is particularly poor in ventral anterior temporal and orbitofrontal regions because of B 0 and B 1 + magnetic field inhomogeneity, a problem that is exacerbated at higher field strengths. In this 7T-fMRI study we compared three methods of improving sensitivity in these areas: parallel transmit, which uses multiple transmit elements, controlled independently, to homogenise the flip angle experienced by the tissue; multi-echo, which entails collection of multiple volumes at different echo times following a single radiofrequency pulse; and multiband, in which multiple slices are acquired simultaneously. We found that parallel transmit and multi-echo increased the magnitude of the BOLD signal change, but only multi-echo increased BOLD magnitude in areas prone to susceptibility artefacts. Multiband and denoising of multi-echo data with independent components analysis (ICA) both improved precision of GLM fit. Exploratory results suggested that multi-echo and ICA denoising can both benefit multivariate analyses. In conclusion, a multi-echo, multiband sequence improved fMRI quality in areas prone to susceptibility artefacts while maintaining sensitivity across the whole brain. We recommend this approach for studies investigating the functional roles of ventral temporal and orbitofrontal regions with 7T fMRI.
Open AccessOptimising 7T-fMRI for imaging regions of magnetic susceptibility
The temporal signal-to-noise ratio (tSNR) of functional magnetic resonance imaging (fMRI) is particularly poor in ventral anterior temporal and orbitofrontal regions because of B 0 and B 1 + magnetic field inhomogeneity, a problem that is exacerbated at higher field strengths. In this 7T-fMRI study we compared three methods of improving sensitivity in these areas: parallel transmit, which uses multiple transmit elements, controlled independently, to homogenise the flip angle experienced by the tissue; multi-echo, which entails collection of multiple volumes at different echo times following a single radiofrequency pulse; and multiband, in which multiple slices are acquired simultaneously. We found that parallel transmit and multi-echo increased the magnitude of the BOLD signal change, but only multi-echo increased BOLD magnitude in areas prone to susceptibility artefacts. Multiband and denoising of multi-echo data with independent components analysis (ICA) both improved precision of GLM fit. Exploratory results suggested that multi-echo and ICA denoising can both benefit multivariate analyses. In conclusion, a multi-echo, multiband sequence improved fMRI quality in areas prone to susceptibility artefacts while maintaining sensitivity across the whole brain. We recommend this approach for studies investigating the functional roles of ventral temporal and orbitofrontal regions with 7T fMRI.
- Open Access
- 26 March 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 111, 35-46
Dynamic parallel transmit diffusion MRI at 7T
- 26 March 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 111, 35-46
Open AccessDynamic parallel transmit diffusion MRI at 7T
- Open Access
- 9 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2358-2373
Bayesian optimization of gradient trajectory for parallel‐transmit pulse design
Purpose: Spoke pulses improve excitation homogeneity in parallel‐transmit MRI. We propose an efficient global optimization algorithm, Bayesian optimization of gradient trajectory (BOGAT), for single‐slice and simultaneous multislice imaging.Theory and Methods: BOGAT adds an outer loop to optimize kT‐space positions. For each position, the RF coefficients are optimized (e.g., with magnitude least squares) and the cost function evaluated. Bayesian optimization progressively estimates the cost function. It automatically chooses the kT‐space positions to sample, to achieve fast convergence, often coming close to the globally optimal spoke positions.We investigated the typical features of spokes cost functions by a grid search with field maps comprising 85 slabs from 14 volunteers.We tested BOGAT in this database, and prospectively in a phantom and in vivo. We compared the vendor‐provided Fourier transform approach with the same magnitude least squares RF optimizer.Results: The cost function is nonconvex and seen empirically to be piecewise smooth with discontinuities where the underlying RF optimum changes sharply. BOGAT converged to within 10% of the global minimum cost within 30 iterations in 93% of slices in our database.BOGAT achieved up to 56% lower flip angle RMS error (RMSE) or 55% lower pulse energy in phantoms versus the Fourier transform approach, and up to 30% lower RMSE and 29% lower energy in vivo with 7.8 s extra computation.Conclusion: BOGAT efficiently estimated near‐global optimum spoke positions for the two‐spoke tests, reducing flip‐angle RMSE and/or pulse energy in a computation time (˜10 s), which is suitable for online optimization.
- 9 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (6) , 2358-2373
Open AccessBayesian optimization of gradient trajectory for parallel‐transmit pulse design
Purpose: Spoke pulses improve excitation homogeneity in parallel‐transmit MRI. We propose an efficient global optimization algorithm, Bayesian optimization of gradient trajectory (BOGAT), for single‐slice and simultaneous multislice imaging.Theory and Methods: BOGAT adds an outer loop to optimize kT‐space positions. For each position, the RF coefficients are optimized (e.g., with magnitude least squares) and the cost function evaluated. Bayesian optimization progressively estimates the cost function. It automatically chooses the kT‐space positions to sample, to achieve fast convergence, often coming close to the globally optimal spoke positions.We investigated the typical features of spokes cost functions by a grid search with field maps comprising 85 slabs from 14 volunteers.We tested BOGAT in this database, and prospectively in a phantom and in vivo. We compared the vendor‐provided Fourier transform approach with the same magnitude least squares RF optimizer.Results: The cost function is nonconvex and seen empirically to be piecewise smooth with discontinuities where the underlying RF optimum changes sharply. BOGAT converged to within 10% of the global minimum cost within 30 iterations in 93% of slices in our database.BOGAT achieved up to 56% lower flip angle RMS error (RMSE) or 55% lower pulse energy in phantoms versus the Fourier transform approach, and up to 30% lower RMSE and 29% lower energy in vivo with 7.8 s extra computation.Conclusion: BOGAT efficiently estimated near‐global optimum spoke positions for the two‐spoke tests, reducing flip‐angle RMSE and/or pulse energy in a computation time (˜10 s), which is suitable for online optimization.
- Open Access
Dynamic parallel transmit diffusion MRI at 7T
Diffusion MRI (dMRI) is inherently limited by SNR. Scanning at 7T increases intrinsic SNR but 7T MRI scans suffer from regions of signal dropout, especially in the temporal lobes and cerebellum. We applied dynamic parallel transmit (pTx) to allow whole-brain 7T dMRI and compared with circularly polarized (CP) pulses in 6 subjects. Subject-specific 2-spoke dynamic pTx pulses were designed offline for 8 slabs covering the brain. We used vendor-provided B 0 and B 1 + mapping. Spokes positions were set using the Fourier difference approach, and RF coefficients optimized with a Jacobi-matrix high-flip-angle optimizer. Diffusion data were analyzed with FSL. Comparing whole-brain averages for pTx against CP scans: mean flip angle error improved by 15% for excitation (2-spoke-VERSE 15.7° vs CP 18.4°, P =0.012) and improved by 14% for refocusing (2-spoke-VERSE 39.7° vs CP 46.2°, P =0.008). Computed spin-echo signal standard deviation improved by 14% (2-spoke-VERSE 0.185 vs 0.214 CP, P =0.025). Temporal SNR increased by 5.4% (2-spoke-VERSE 8.47 vs CP 8.04, P=0.004) especially in the inferior temporal lobes. Diffusion fitting uncertainty decreased by 6.2% for first fibres (2-spoke VERSE 0.0655 vs CP 0.0703, P vs CP 0.141, P =0.01). In conclusion, dynamic parallel transmit improves the uniformity of 7T diffusion-weighted imaging. In future, less restrictive SAR limits for parallel transmit scans are expected to allow further improvements.
Open AccessDynamic parallel transmit diffusion MRI at 7T
Diffusion MRI (dMRI) is inherently limited by SNR. Scanning at 7T increases intrinsic SNR but 7T MRI scans suffer from regions of signal dropout, especially in the temporal lobes and cerebellum. We applied dynamic parallel transmit (pTx) to allow whole-brain 7T dMRI and compared with circularly polarized (CP) pulses in 6 subjects. Subject-specific 2-spoke dynamic pTx pulses were designed offline for 8 slabs covering the brain. We used vendor-provided B 0 and B 1 + mapping. Spokes positions were set using the Fourier difference approach, and RF coefficients optimized with a Jacobi-matrix high-flip-angle optimizer. Diffusion data were analyzed with FSL. Comparing whole-brain averages for pTx against CP scans: mean flip angle error improved by 15% for excitation (2-spoke-VERSE 15.7° vs CP 18.4°, P =0.012) and improved by 14% for refocusing (2-spoke-VERSE 39.7° vs CP 46.2°, P =0.008). Computed spin-echo signal standard deviation improved by 14% (2-spoke-VERSE 0.185 vs 0.214 CP, P =0.025). Temporal SNR increased by 5.4% (2-spoke-VERSE 8.47 vs CP 8.04, P=0.004) especially in the inferior temporal lobes. Diffusion fitting uncertainty decreased by 6.2% for first fibres (2-spoke VERSE 0.0655 vs CP 0.0703, P vs CP 0.141, P =0.01). In conclusion, dynamic parallel transmit improves the uniformity of 7T diffusion-weighted imaging. In future, less restrictive SAR limits for parallel transmit scans are expected to allow further improvements.