Modelflow underestimates cardiac output in heat-stressed individuals
- 1 February 2011
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Vol. 300 (2) , R486-R491
Abstract
An estimation of cardiac output can be obtained from arterial pressure waveforms using the Modelflow method. However, whether the assumptions associated with Modelflow calculations are accurate during whole body heating is unknown. This project tested the hypothesis that cardiac output obtained via Modelflow accurately tracks thermodilution-derived cardiac outputs during whole body heat stress. Acute changes of cardiac output were accomplished via lower-body negative pressure (LBNP) during normothermic and heat-stressed conditions. In nine healthy normotensive subjects, arterial pressure was measured via brachial artery cannulation and the volume-clamp method of the Finometer. Cardiac output was estimated from both pressure waveforms using the Modeflow method. In normothermic conditions, cardiac outputs estimated via Modelflow (arterial cannulation: 6.1 ± 1.0 l/min; Finometer 6.3 ± 1.3 l/min) were similar with cardiac outputs measured by thermodilution (6.4 ± 0.8 l/min). The subsequent reduction in cardiac output during LBNP was also similar among these methods. Whole body heat stress elevated internal temperature from 36.6 ± 0.3 to 37.8 ± 0.4°C and increased cardiac output from 6.4 ± 0.8 to 10.9 ± 2.0 l/min when evaluated with thermodilution (P < 0.001). However, the increase in cardiac output estimated from the Modelflow method for both arterial cannulation (2.3 ± 1.1 l/min) and Finometer (1.5 ± 1.2 l/min) was attenuated compared with thermodilution (4.5 ± 1.4 l/min, both P < 0.01). Finally, the reduction in cardiac output during LBNP while heat stressed was significantly attenuated for both Modelflow methods (cannulation: −1.8 ± 1.2 l/min, Finometer: −1.5 ± 0.9 l/min) compared with thermodilution (−3.8 ± 1.19 l/min). These results demonstrate that the Modelflow method, regardless of Finometer or direct arterial waveforms, underestimates cardiac output during heat stress and during subsequent reductions in cardiac output via LBNP.Keywords
This publication has 28 references indexed in Scilit:
- Modelflow estimates of cardiac output compared with Doppler ultrasound during acute changes in vascular resistance in womenExperimental Physiology, 2010
- Increased left ventricular twist, untwisting rates, and suction maintain global diastolic function during passive heat stress in humansAmerican Journal of Physiology-Heart and Circulatory Physiology, 2010
- Continuous Arterial Pressure Waveform Analysis Accurately Detects Cardiac Output in Cardiac Surgery: A Prospective Comparison with Thermodilution, Echocardiography, and Magnetic Resonance TechniquesThe Heart Surgery Forum, 2009
- Effects of passive heating on central blood volume and ventricular dimensions in humansThe Journal of Physiology, 2008
- Modelflow: a new method for noninvasive assessment of cardiac output in pregnant womenAmerican Journal of Obstetrics and Gynecology, 2007
- Heat stress reduces cerebral blood velocity and markedly impairs orthostatic tolerance in humansAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2006
- Echocardiographic assessment of aortic elastic properties with automated border detection in an ICU: in vivo application of the arctangent Langewouters modelAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Non‐invasive assessment of cardiac output during exercise in healthy young humans: comparison between Modelflow method and Doppler echocardiography methodActa Physiologica Scandinavica, 2003
- Continuous Cardiac Output in Septic Shock by Simulating a Model of the Aortic Input ImpedanceAnesthesiology, 1999
- The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new modelJournal of Biomechanics, 1984