Abstract
Radiation-induced attenuation (RIA) based dosimetry exploiting phosphosilicate optical fiber has been established as a reliable and precise dosimetry technique, able to monitor the total ionizing dose in a variety of harsh environments. We evaluate here the potential of this technology to monitor 14 MeV and atmospheric neutrons. Experiments performed at the TNF facility from TRIUMF and FNG from ENEA demonstrate, that after calibration, the fiber dosimeter can serve as an efficient fluence monitor, the RIA being linearly dependent on the neutron fluence. Using Geant4 simulations, we show that the radiation sensitivity of the fiber, around 3.5 dB km -1 Gy -1 for 14 MeV neutrons agrees with the ones found in previous studies for photons and protons. For atmospheric neutrons, the calibration differs by a factor of up to 2.5 with respect to usual factor. Extensive simulations are performed showing that in these neutron environments, the consideration of the real 3D structure of the fiber coil is mandatory for a fine calibration of the dosimeter. Perspectives for fiber dosimetry of neutron rich environments are then discussed.
Funding Information
  • European Union’s Horizon 2020 Research and Innovation Program (101008126)

This publication has 43 references indexed in Scilit: