Evaluation of a Semi-automatic Right Ventricle Segmentation Method on Short-Axis MR Images
Open Access
- 9 March 2018
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 31 (5) , 670-679
Abstract
The purpose of this study was to evaluate a semi-automatic right ventricle segmentation method on short-axis cardiac cine MR images which segment all right ventricle contours in a cardiac phase using one seed contour. Twenty-eight consecutive short-axis, four-chamber, and tricuspid valve view cardiac cine MRI examinations of healthy volunteers were used. Two independent observers performed the manual and automatic segmentations of the right ventricles. Analyses were based on the ventricular volume and ejection fraction of the right heart chamber. Reproducibility of the manual and semi-automatic segmentations was assessed using intra- and inter-observer variability. Validity of the semi-automatic segmentations was analyzed with reference to the manual segmentations. The inter- and intra-observer variability of manual segmentations were between 0.8 and 3.2%. The semi-automatic segmentations were highly correlated with the manual segmentations (R2 0.79–0.98), with median difference of 0.9–4.8% and of 3.3% for volume and ejection fraction parameters, respectively. In comparison to the manual segmentation, the semi-automatic segmentation produced contours with median dice metrics of 0.95 and 0.87 and median Hausdorff distance of 5.05 and 7.35 mm for contours at end-diastolic and end-systolic phases, respectively. The inter- and intra-observer variability of the semi-automatic segmentations were lower than observed in the manual segmentations. Both manual and semi-automatic segmentations performed better at the end-diastolic phase than at the end-systolic phase. The investigated semi-automatic segmentation method managed to produce a valid and reproducible alternative to manual right ventricle segmentation.Keywords
Funding Information
- University Medical Center Rotterdam
This publication has 41 references indexed in Scilit:
- Cardiac MRI Assessment of Right Ventricular Function in Acquired Heart DiseaseAcademic Radiology, 2012
- Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MREuropean Radiology, 2012
- A review of segmentation methods in short axis cardiac MR imagesMedical Image Analysis, 2011
- Intra-observer and interobserver variability of biventricular function, volumes and mass in patients with congenital heart disease measured by CMR imagingThe International Journal of Cardiovascular Imaging, 2009
- Reproducibility of MRI measurements of right ventricular size and function in patients with normal and dilated ventriclesJournal of Magnetic Resonance Imaging, 2008
- Evaluating the systemic right ventricle by CMR: the importance of consistent and reproducible delineation of the cavityJournal of Cardiovascular Magnetic Resonance, 2008
- Evaluation of manual and automatic segmentation of the mouse heart from CINE MR imagesJournal of Magnetic Resonance Imaging, 2007
- Operator Induced Variability in Left Ventricular Measurements with Cardiovascular Magnetic Resonance is Improved After TrainingJournal of Cardiovascular Magnetic Resonance, 2007
- Routine breath-hold gradient echo MRI-derived right ventricular mass, volumes and function: accuracy, reproducibility and coherence studyThe International Journal of Cardiovascular Imaging, 2004
- Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady‐state free precession imaging sequencesJournal of Magnetic Resonance Imaging, 2003