Jean-Paul Aben
Research Subjects
Jean-Paul Aben has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Adriaan Moelker
Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, Zuid-Holland, Netherlands
1 shared publication - Andrew James Swift
School of Medicine & Population Health, The University of Sheffield, Sheffield S10 2TN, UK
1 shared publication - Chao Gao
The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China
1 shared publication - Ciaran Grafton-Clarke
School of Medicine, University of East Anglia , Norwich
1 shared publication - Darren Mylotte
Discipline of Cardiology, Saolta Group, Galway University Hospital, Health Service Executive and CORRIB Core Lab, National University of Ireland Galway (NUIG), H91 V4AY Galway, Ireland
1 shared publication - David Rodney Hose
University of Sheffield
1 shared publication
Latest Publications
- Open Access
- 29 April 2022
- Published by Springer Nature in BMC Research Notes
- Vol. 15 (1) , 1-7
Validation of aortic valve pressure gradient quantification using semi-automated 4D flow CMR pipeline
Objective: Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is emerging as a valuable diagnostic tool for estimating the peak pressure drop across the aortic valve, but assessment remains cumbersome. We aimed to validate a novel semi-automated pipeline 4D flow CMR method of assessing peak aortic value pressure gradient (AVPG) using the commercially available software solution, CAAS MR Solutions, against invasive angiographic methods. Results: We enrolled 11 patients with severe AS on echocardiography from the EurValve programme. All patients had pre-intervention doppler echocardiography, invasive cardiac catheterisation with peak pressure drop assessment across the AV and 4D flow CMR. The peak AVPG was 51.9 ± 35.2 mmHg using the invasive pressure drop method and 52.2 ± 29.2 mmHg for the 4D flow CMR method (semi-automated pipeline), with good correlation between the two methods (r = 0.70, p = 0.017). Assessment of AVPG by 4D flow CMR using the novel semi-automated pipeline method shows excellent agreement to invasive assessment when compared to doppler-based methods and advocate for its use as complementary to echocardiography.
- 29 April 2022
- Published by Springer Nature in BMC Research Notes
- Vol. 15 (1) , 1-7
Open AccessValidation of aortic valve pressure gradient quantification using semi-automated 4D flow CMR pipeline
Objective: Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is emerging as a valuable diagnostic tool for estimating the peak pressure drop across the aortic valve, but assessment remains cumbersome. We aimed to validate a novel semi-automated pipeline 4D flow CMR method of assessing peak aortic value pressure gradient (AVPG) using the commercially available software solution, CAAS MR Solutions, against invasive angiographic methods. Results: We enrolled 11 patients with severe AS on echocardiography from the EurValve programme. All patients had pre-intervention doppler echocardiography, invasive cardiac catheterisation with peak pressure drop assessment across the AV and 4D flow CMR. The peak AVPG was 51.9 ± 35.2 mmHg using the invasive pressure drop method and 52.2 ± 29.2 mmHg for the 4D flow CMR method (semi-automated pipeline), with good correlation between the two methods (r = 0.70, p = 0.017). Assessment of AVPG by 4D flow CMR using the novel semi-automated pipeline method shows excellent agreement to invasive assessment when compared to doppler-based methods and advocate for its use as complementary to echocardiography.
- Open Access
- 4 August 2021
- Published by Ubiquity Press, Ltd. in Global Heart
- Vol. 16 (1)
Quantitative Angiographic Assessment of Aortic Regurgitation After Transcatheter Implantation of the Venus A-valve: Comparison with Other Self-Expanding Valves and Impact of a Learning Curve in a Single Chinese Center
We aimed to compare the quantitative angiographic aortic regurgitation (AR) into the left ventricular out flow tract (LVOT-AR) of five different types of transcatheter self-expanding valves and to investigate the impact of the learning curve on post-TAVR AR. Quantitative video densitometric aortography is an objective, accurate, and reproducible tool for assessment of AR following TAVR. This retrospective academic core-lab analysis, analyzed 1150 consecutive cine aortograms performed immediately post-TAVR. Quantitative angiographic AR of post-procedural aortography in 181 consecutive patients, who underwent TAVR with the Venus A-valve in a single Chinese center, were compared to the results of Evolut Pro, Evolut R, CoreValve, (Medtronic, Dublin, Ireland) and Acurate Neo (Boston Scientific, Massachusetts, US) transcatheter heart valves (THVs), from a previously published pooled database. Among the 181 aortograms of patients treated with the Venus A-Valve, 113 (62.4%) were analyzable for quantitative assessment of AR. The mean LVOT-AR was 8.9% ± 10.0% with 14.2% of patients having moderate or severe AR in the Venus A-valve group. No significant difference in mean LVOT-AR was observed between Evolut Pro, Evolut R, Acurate Neo, and Venus A-valve. The incidence of LVOT-AR >17%, which correlates with echocardiographic derived ≥ moderate AR, with the Evolut Pro was lower than with the Venus A-valve (5.3% vs. 14.2%, p = 0.034), but was not different from the Evolut R (5.3% vs. 8.8%, p = 0.612), or the Acurate Neo (5.3% vs. 11.3% p = 0.16) systems. A landmark analysis after recruitment of the first half of patients treated with the Venus A valve (N = 56), showed a significantly lower mean LVOT-AR in the second half of the series (11.3% ± 11.9% vs. 6.5% ± 7.1%, p = 0.011). The incidence of LVOT-AR >17% in the latest 57 cases was also numerically lower (7.0% vs. 21.4%, p = 0.857) and compared favorably with the best in class of the self-expanding valves. The Venus A-valve has comparable mean LVOT-AR to other self-expanding valves but has a higher rate of moderate or severe AR than the Evolut Pro THV. However, after completion of a learning phase, results improved and compared favorably with the best in class of the commercially available self-expanding valves. These findings should be confirmed in prospective randomized comparisons of AR between different THVs.
- 4 August 2021
- Published by Ubiquity Press, Ltd. in Global Heart
- Vol. 16 (1)
Open AccessQuantitative Angiographic Assessment of Aortic Regurgitation After Transcatheter Implantation of the Venus A-valve: Comparison with Other Self-Expanding Valves and Impact of a Learning Curve in a Single Chinese Center
We aimed to compare the quantitative angiographic aortic regurgitation (AR) into the left ventricular out flow tract (LVOT-AR) of five different types of transcatheter self-expanding valves and to investigate the impact of the learning curve on post-TAVR AR. Quantitative video densitometric aortography is an objective, accurate, and reproducible tool for assessment of AR following TAVR. This retrospective academic core-lab analysis, analyzed 1150 consecutive cine aortograms performed immediately post-TAVR. Quantitative angiographic AR of post-procedural aortography in 181 consecutive patients, who underwent TAVR with the Venus A-valve in a single Chinese center, were compared to the results of Evolut Pro, Evolut R, CoreValve, (Medtronic, Dublin, Ireland) and Acurate Neo (Boston Scientific, Massachusetts, US) transcatheter heart valves (THVs), from a previously published pooled database. Among the 181 aortograms of patients treated with the Venus A-Valve, 113 (62.4%) were analyzable for quantitative assessment of AR. The mean LVOT-AR was 8.9% ± 10.0% with 14.2% of patients having moderate or severe AR in the Venus A-valve group. No significant difference in mean LVOT-AR was observed between Evolut Pro, Evolut R, Acurate Neo, and Venus A-valve. The incidence of LVOT-AR >17%, which correlates with echocardiographic derived ≥ moderate AR, with the Evolut Pro was lower than with the Venus A-valve (5.3% vs. 14.2%, p = 0.034), but was not different from the Evolut R (5.3% vs. 8.8%, p = 0.612), or the Acurate Neo (5.3% vs. 11.3% p = 0.16) systems. A landmark analysis after recruitment of the first half of patients treated with the Venus A valve (N = 56), showed a significantly lower mean LVOT-AR in the second half of the series (11.3% ± 11.9% vs. 6.5% ± 7.1%, p = 0.011). The incidence of LVOT-AR >17% in the latest 57 cases was also numerically lower (7.0% vs. 21.4%, p = 0.857) and compared favorably with the best in class of the self-expanding valves. The Venus A-valve has comparable mean LVOT-AR to other self-expanding valves but has a higher rate of moderate or severe AR than the Evolut Pro THV. However, after completion of a learning phase, results improved and compared favorably with the best in class of the commercially available self-expanding valves. These findings should be confirmed in prospective randomized comparisons of AR between different THVs.
- Open Access
- 9 March 2018
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 31 (5) , 670-679
Evaluation of a Semi-automatic Right Ventricle Segmentation Method on Short-Axis MR Images
The purpose of this study was to evaluate a semi-automatic right ventricle segmentation method on short-axis cardiac cine MR images which segment all right ventricle contours in a cardiac phase using one seed contour. Twenty-eight consecutive short-axis, four-chamber, and tricuspid valve view cardiac cine MRI examinations of healthy volunteers were used. Two independent observers performed the manual and automatic segmentations of the right ventricles. Analyses were based on the ventricular volume and ejection fraction of the right heart chamber. Reproducibility of the manual and semi-automatic segmentations was assessed using intra- and inter-observer variability. Validity of the semi-automatic segmentations was analyzed with reference to the manual segmentations. The inter- and intra-observer variability of manual segmentations were between 0.8 and 3.2%. The semi-automatic segmentations were highly correlated with the manual segmentations (R2 0.79–0.98), with median difference of 0.9–4.8% and of 3.3% for volume and ejection fraction parameters, respectively. In comparison to the manual segmentation, the semi-automatic segmentation produced contours with median dice metrics of 0.95 and 0.87 and median Hausdorff distance of 5.05 and 7.35 mm for contours at end-diastolic and end-systolic phases, respectively. The inter- and intra-observer variability of the semi-automatic segmentations were lower than observed in the manual segmentations. Both manual and semi-automatic segmentations performed better at the end-diastolic phase than at the end-systolic phase. The investigated semi-automatic segmentation method managed to produce a valid and reproducible alternative to manual right ventricle segmentation.
- 9 March 2018
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 31 (5) , 670-679
Open AccessEvaluation of a Semi-automatic Right Ventricle Segmentation Method on Short-Axis MR Images
The purpose of this study was to evaluate a semi-automatic right ventricle segmentation method on short-axis cardiac cine MR images which segment all right ventricle contours in a cardiac phase using one seed contour. Twenty-eight consecutive short-axis, four-chamber, and tricuspid valve view cardiac cine MRI examinations of healthy volunteers were used. Two independent observers performed the manual and automatic segmentations of the right ventricles. Analyses were based on the ventricular volume and ejection fraction of the right heart chamber. Reproducibility of the manual and semi-automatic segmentations was assessed using intra- and inter-observer variability. Validity of the semi-automatic segmentations was analyzed with reference to the manual segmentations. The inter- and intra-observer variability of manual segmentations were between 0.8 and 3.2%. The semi-automatic segmentations were highly correlated with the manual segmentations (R2 0.79–0.98), with median difference of 0.9–4.8% and of 3.3% for volume and ejection fraction parameters, respectively. In comparison to the manual segmentation, the semi-automatic segmentation produced contours with median dice metrics of 0.95 and 0.87 and median Hausdorff distance of 5.05 and 7.35 mm for contours at end-diastolic and end-systolic phases, respectively. The inter- and intra-observer variability of the semi-automatic segmentations were lower than observed in the manual segmentations. Both manual and semi-automatic segmentations performed better at the end-diastolic phase than at the end-systolic phase. The investigated semi-automatic segmentation method managed to produce a valid and reproducible alternative to manual right ventricle segmentation.