DCE-Qnet: Deep Network Quantification of Dynamic Contrast Enhanced (DCE) MRI
Authors:
Preprint
Abstract
Introduction: Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. Methods: A 7-layer neural network called DCE-Qnet was trained on simulated DCE-MRI signals derived from the Extended Tofts model with the Parker arterial input function. Network training incorporated B1 inhomogeneities to estimate perfusion (Ktrans, vp, ve), tissue T1 relaxation, proton density and bolus arrival time (BAT). The accuracy was tested in a digital phantom in comparison to a conventional nonlinear least-squares fitting (NLSQ). In vivo testing was conducted in 10 healthy subjects. Regions of interest in the cervix and uterine myometrium were used to calculate the inter-subject variability. The clinical utility was demonstrated on a cervical cancer patient. Test-retest experiments were used to assess reproducibility of the parameter maps in the tumor. Results: The DCE-Qnet reconstruction outperformed NLSQ in the phantom. The coefficient of variation (CV) in the healthy cervix varied between 5-51% depending on the parameter. Parameter values in the tumor agreed with previous studies despite differences in methodology. The CV in the tumor varied between 1-47%. Conclusion: The proposed approach provides comprehensive DCE-MRI quantification from a single acquisition. DCE-Qnet eliminates the need for separate T1 scan or BAT processing, leading to a reduction of 10 minutes per scan and more accurate quantification.Keywords
All Related Versions
This publication has 35 references indexed in Scilit:
- VTDCE‐Net: A time invariant deep neural network for direct estimation of pharmacokinetic parameters from undersampled DCE MRI dataMedical Physics, 2022
- Estimation of pharmacokinetic parameters from DCE‐MRI by extracting long and short time‐dependent features using an LSTM networkMedical Physics, 2020
- Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRIMagnetic Resonance in Medicine, 2013
- On the scope and interpretation of the Tofts models for DCE‐MRIMagnetic Resonance in Medicine, 2011
- The effect of blood inflow and B1‐field inhomogeneity on measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2010
- Comparison of quantitative parameters in cervix cancer measured by dynamic contrast–enhanced MRI and CTMagnetic Resonance in Medicine, 2010
- B1 mapping by Bloch‐Siegert shiftMagnetic Resonance in Medicine, 2010
- A comparison of tracer kinetic models for T 1 -weighted dynamic contrast-enhanced MRI: Application in carcinoma of the cervixMagnetic Resonance in Medicine, 2010
- Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2006
- Modeling tracer kinetics in dynamic Gd‐DTPA MR imagingJournal of Magnetic Resonance Imaging, 1997