Ouri Cohen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ouri Cohen has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Scott Rosen
A.A. Martinos Center for Biomedical Imaging, Department of Radiology (J.E.I., M.S.R.), Mass General Brigham and Harvard Medical School, Boston
4 shared publications - Or Perlman
Tel Aviv University
4 shared publications - Ricardo Otazo
Department of Medical Physics Memorial Sloan Kettering Cancer Center New York New York USA
4 shared publications - Christian T. Farrar
Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital
3 shared publications - Moritz Zaiss
Institute of Neuroradiology, Uniklinikum Erlangen, Friedrich-Alexander-University (FAU) Erlangen-Nuremberg
3 shared publications Robert J. Young
Department of Radiology Memorial Sloan Kettering Cancer Center New York New York USA
3 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (12)
Quantitative Chemical Exchange Saturation Transfer Imaging With Golden‐Angle Radial k‐Space Sampling and Locally Low‐Rank Reconstruction
Chemical exchange saturation transfer magnetic resonance fingerprinting (CEST‐MRF) is a promising quantitative molecular imaging technique. To reduce scan time, current CEST‐MRF implementations typically use echo‐planar imaging (EPI) readouts, which are prone to geometric distortion and signal dropout. In this study, we developed a motion‐robust, geometrically accurate CEST‐MRF method using radial k‐space sampling, locally low‐rank reconstruction, and neural network–based quantification. The acquisition schedule was optimized using deep learning, and its accuracy was validated in numerical simulations with digital phantoms. The number of spokes per measurement was determined through simulations and in vivo ablation studies in healthy volunteers. Five healthy subjects underwent repeated scans, and regions of interest were defined for analysis. Tissue maps generated with the proposed method were compared with values obtained from nonlinear least‐squares (NLS) fitting of multisaturation‐power z‐spectra. Motion sensitivity and test–retest reproducibility were evaluated using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Clinical feasibility was demonstrated in a subject with a history of remote middle cerebral artery infarction. The results show that 3D quantitative CEST maps can be acquired in 11 min using 34 spokes per measurement. Numerical simulations yielded mean errors below 14% for all tissue parameters, while in vivo parameter estimates agreed well with both NLS‐derived values and prior brain CEST‐MRF studies. The mean ICC across all tissue maps was 0.92 in white matter and 0.87 in gray matter, with mean intersubject CVs of 5.4% and 3.4%, respectively. The mean error between motion and no‐motion conditions was 8.6%. In the pathology case, changes in CEST‐MRF tissue parameters were consistent with clinically diagnosed cystic gliosis. This approach enables accurate and reproducible 3D quantitative CEST imaging of the brain within clinically feasible scan times.
- 21 October 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (12)
Open AccessQuantitative Chemical Exchange Saturation Transfer Imaging With Golden‐Angle Radial k‐Space Sampling and Locally Low‐Rank Reconstruction
Chemical exchange saturation transfer magnetic resonance fingerprinting (CEST‐MRF) is a promising quantitative molecular imaging technique. To reduce scan time, current CEST‐MRF implementations typically use echo‐planar imaging (EPI) readouts, which are prone to geometric distortion and signal dropout. In this study, we developed a motion‐robust, geometrically accurate CEST‐MRF method using radial k‐space sampling, locally low‐rank reconstruction, and neural network–based quantification. The acquisition schedule was optimized using deep learning, and its accuracy was validated in numerical simulations with digital phantoms. The number of spokes per measurement was determined through simulations and in vivo ablation studies in healthy volunteers. Five healthy subjects underwent repeated scans, and regions of interest were defined for analysis. Tissue maps generated with the proposed method were compared with values obtained from nonlinear least‐squares (NLS) fitting of multisaturation‐power z‐spectra. Motion sensitivity and test–retest reproducibility were evaluated using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Clinical feasibility was demonstrated in a subject with a history of remote middle cerebral artery infarction. The results show that 3D quantitative CEST maps can be acquired in 11 min using 34 spokes per measurement. Numerical simulations yielded mean errors below 14% for all tissue parameters, while in vivo parameter estimates agreed well with both NLS‐derived values and prior brain CEST‐MRF studies. The mean ICC across all tissue maps was 0.92 in white matter and 0.87 in gray matter, with mean intersubject CVs of 5.4% and 3.4%, respectively. The mean error between motion and no‐motion conditions was 8.6%. In the pathology case, changes in CEST‐MRF tissue parameters were consistent with clinically diagnosed cystic gliosis. This approach enables accurate and reproducible 3D quantitative CEST imaging of the brain within clinically feasible scan times.
- Open Access
- 14 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 541-553
Quantitative multislice and jointly optimized rapid CEST for in vivo whole‐brain imaging
Purpose: To develop a quantitative multislice chemical exchange saturation transfer (CEST) schedule optimization and pulse sequence that reduces the loss of sensitivity inherent to multislice sequences. Methods: A deep learning framework was developed for simultaneous optimization of scan parameters and slice order. The optimized sequence was tested in numerical simulations against a random schedule and an optimized single‐slice schedule. The scan efficiency of each schedule was quantified. Three healthy subjects were scanned with the proposed sequence. Regions of interest in white matter (WM) and gray matter (GM) were defined. The sequence was compared with the single‐slice sequence in vivo and differences quantified using Bland–Altman plots. Test–retest reproducibility was assessed, and the Lin's concordance correlation coefficient (CCC) was calculated for WM and GM. Intersubject variability was also measured with the CCC. Feasibility of whole‐brain clinical imaging was tested using a multislab acquisition in 1 subject. Results: The optimized multislice sequence yielded a lower mean error than the random schedule for all tissue parameters and a lower error than the optimized single‐slice schedule for four of six parameters. The optimized multislice sequence provided the highest scan efficiency. In vivo tissue‐parameter values obtained with the proposed sequence agreed well with those of the optimized single‐slice sequence and prior studies. The average WM/GM CCC was 0.8151/0.7779 for the test–retest scans and 0.7792/0.7191 for the intersubject variability experiment. Conclusion: A multislice schedule optimization framework and pulse sequence were demonstrated for quantitative CEST. The proposed approach enables accurate and reproducible whole‐brain quantitative CEST imaging in clinically relevant scan times.
- 14 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 541-553
Open AccessQuantitative multislice and jointly optimized rapid CEST for in vivo whole‐brain imaging
Purpose: To develop a quantitative multislice chemical exchange saturation transfer (CEST) schedule optimization and pulse sequence that reduces the loss of sensitivity inherent to multislice sequences. Methods: A deep learning framework was developed for simultaneous optimization of scan parameters and slice order. The optimized sequence was tested in numerical simulations against a random schedule and an optimized single‐slice schedule. The scan efficiency of each schedule was quantified. Three healthy subjects were scanned with the proposed sequence. Regions of interest in white matter (WM) and gray matter (GM) were defined. The sequence was compared with the single‐slice sequence in vivo and differences quantified using Bland–Altman plots. Test–retest reproducibility was assessed, and the Lin's concordance correlation coefficient (CCC) was calculated for WM and GM. Intersubject variability was also measured with the CCC. Feasibility of whole‐brain clinical imaging was tested using a multislab acquisition in 1 subject. Results: The optimized multislice sequence yielded a lower mean error than the random schedule for all tissue parameters and a lower error than the optimized single‐slice schedule for four of six parameters. The optimized multislice sequence provided the highest scan efficiency. In vivo tissue‐parameter values obtained with the proposed sequence agreed well with those of the optimized single‐slice sequence and prior studies. The average WM/GM CCC was 0.8151/0.7779 for the test–retest scans and 0.7792/0.7191 for the intersubject variability experiment. Conclusion: A multislice schedule optimization framework and pulse sequence were demonstrated for quantitative CEST. The proposed approach enables accurate and reproducible whole‐brain quantitative CEST imaging in clinically relevant scan times.
- 8 August 2024
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 37 (6) , 1077-1090
DCE-Qnet: deep network quantification of dynamic contrast enhanced (DCE) MRI
Introduction Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. Methods A 7-layer neural network called DCE-Qnet was trained on simulated DCE-MRI signals derived from the Extended Tofts model with the Parker arterial input function. Network training incorporated B1 inhomogeneities to estimate perfusion (Ktrans, vp, ve), tissue T1 relaxation, proton density and bolus arrival time (BAT). The accuracy was tested in a digital phantom in comparison to a conventional nonlinear least-squares fitting (NLSQ). In vivo testing was conducted in ten healthy subjects. Regions of interest in the cervix and uterine myometrium were used to calculate the inter-subject variability. The clinical utility was demonstrated on a cervical cancer patient. Test–retest experiments were used to assess reproducibility of the parameter maps in the tumor. Results The DCE-Qnet reconstruction outperformed NLSQ in the phantom. The coefficient of variation (CV) in the healthy cervix varied between 5 and 51% depending on the parameter. Parameter values in the tumor agreed with previous studies despite differences in methodology. The CV in the tumor varied between 1 and 47%. Conclusion The proposed approach provides comprehensive DCE-MRI quantification from a single acquisition. DCE-Qnet eliminates the need for separate T1 scan or BAT processing, leading to a reduction of 10 min per scan and more accurate quantification.
- 8 August 2024
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 37 (6) , 1077-1090
DCE-Qnet: deep network quantification of dynamic contrast enhanced (DCE) MRI
Introduction Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. Methods A 7-layer neural network called DCE-Qnet was trained on simulated DCE-MRI signals derived from the Extended Tofts model with the Parker arterial input function. Network training incorporated B1 inhomogeneities to estimate perfusion (Ktrans, vp, ve), tissue T1 relaxation, proton density and bolus arrival time (BAT). The accuracy was tested in a digital phantom in comparison to a conventional nonlinear least-squares fitting (NLSQ). In vivo testing was conducted in ten healthy subjects. Regions of interest in the cervix and uterine myometrium were used to calculate the inter-subject variability. The clinical utility was demonstrated on a cervical cancer patient. Test–retest experiments were used to assess reproducibility of the parameter maps in the tumor. Results The DCE-Qnet reconstruction outperformed NLSQ in the phantom. The coefficient of variation (CV) in the healthy cervix varied between 5 and 51% depending on the parameter. Parameter values in the tumor agreed with previous studies despite differences in methodology. The CV in the tumor varied between 1 and 47%. Conclusion The proposed approach provides comprehensive DCE-MRI quantification from a single acquisition. DCE-Qnet eliminates the need for separate T1 scan or BAT processing, leading to a reduction of 10 min per scan and more accurate quantification.
- Open Access
DCE-Qnet: Deep Network Quantification of Dynamic Contrast Enhanced (DCE) MRI
Introduction: Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. Methods: A 7-layer neural network called DCE-Qnet was trained on simulated DCE-MRI signals derived from the Extended Tofts model with the Parker arterial input function. Network training incorporated B1 inhomogeneities to estimate perfusion (Ktrans, vp, ve), tissue T1 relaxation, proton density and bolus arrival time (BAT). The accuracy was tested in a digital phantom in comparison to a conventional nonlinear least-squares fitting (NLSQ). In vivo testing was conducted in 10 healthy subjects. Regions of interest in the cervix and uterine myometrium were used to calculate the inter-subject variability. The clinical utility was demonstrated on a cervical cancer patient. Test-retest experiments were used to assess reproducibility of the parameter maps in the tumor. Results: The DCE-Qnet reconstruction outperformed NLSQ in the phantom. The coefficient of variation (CV) in the healthy cervix varied between 5-51% depending on the parameter. Parameter values in the tumor agreed with previous studies despite differences in methodology. The CV in the tumor varied between 1-47%. Conclusion: The proposed approach provides comprehensive DCE-MRI quantification from a single acquisition. DCE-Qnet eliminates the need for separate T1 scan or BAT processing, leading to a reduction of 10 minutes per scan and more accurate quantification.
Open AccessDCE-Qnet: Deep Network Quantification of Dynamic Contrast Enhanced (DCE) MRI
Introduction: Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. Methods: A 7-layer neural network called DCE-Qnet was trained on simulated DCE-MRI signals derived from the Extended Tofts model with the Parker arterial input function. Network training incorporated B1 inhomogeneities to estimate perfusion (Ktrans, vp, ve), tissue T1 relaxation, proton density and bolus arrival time (BAT). The accuracy was tested in a digital phantom in comparison to a conventional nonlinear least-squares fitting (NLSQ). In vivo testing was conducted in 10 healthy subjects. Regions of interest in the cervix and uterine myometrium were used to calculate the inter-subject variability. The clinical utility was demonstrated on a cervical cancer patient. Test-retest experiments were used to assess reproducibility of the parameter maps in the tumor. Results: The DCE-Qnet reconstruction outperformed NLSQ in the phantom. The coefficient of variation (CV) in the healthy cervix varied between 5-51% depending on the parameter. Parameter values in the tumor agreed with previous studies despite differences in methodology. The CV in the tumor varied between 1-47%. Conclusion: The proposed approach provides comprehensive DCE-MRI quantification from a single acquisition. DCE-Qnet eliminates the need for separate T1 scan or BAT processing, leading to a reduction of 10 minutes per scan and more accurate quantification.
- Open Access
- 11 April 2024
- Published by Springer Nature in Research Square
Quantitative Molecular Imaging using Deep Magnetic Resonance Fingerprinting
Deep learning-based saturation-transfer magnetic resonance fingerprinting (MRF) is an emerging approach for noninvasive in vivo imaging of proteins, metabolites, and pH. It involves a series of steps, including (i) sample/subject preparation, (ii) image acquisition schedule design, (iii) biophysical model formulation, (iv) artificial intelligence (AI) and computational model training, followed by (v) image acquisition, (vi) deep reconstruction, and (vii) analysis. The saturation-transfer-based molecular MRI field has been slow to reach clinical maturity and adoption for clinical practice due to its technical complexity, semi-quantitative contrast-weighted nature, and impractically long scan times needed for the extraction of quantitative molecular biomarkers. Deep MRF constitutes a remedy for these challenges, providing a quantitative and rapid framework for extracting biologically and/or clinically meaningful molecular information. Here, we define a standardized protocol and a practical, complete guide for quantitative molecular MRI using deep MRF. We describe in-vitro sample preparation, animal and human scan considerations, and provide intuition behind acquisition protocol design and optimization of chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) quantitative imaging. We then extensively describe the building blocks for several AI models and demonstrate their performance for different applications, including cancer monitoring, brain myelin imaging, and pH quantification. Finally, explicit guidelines for further modification and expansion of the pipeline for imaging a variety of other pathologies (such as neurodegeneration, stroke, and cardiac disease) are given, accompanied by detailed open-source code and sample data. The protocol takes ~48 min - 57 hrs to complete by a scientist at the graduate student level.
- 11 April 2024
- Published by Springer Nature in Research Square
Open AccessQuantitative Molecular Imaging using Deep Magnetic Resonance Fingerprinting
Deep learning-based saturation-transfer magnetic resonance fingerprinting (MRF) is an emerging approach for noninvasive in vivo imaging of proteins, metabolites, and pH. It involves a series of steps, including (i) sample/subject preparation, (ii) image acquisition schedule design, (iii) biophysical model formulation, (iv) artificial intelligence (AI) and computational model training, followed by (v) image acquisition, (vi) deep reconstruction, and (vii) analysis. The saturation-transfer-based molecular MRI field has been slow to reach clinical maturity and adoption for clinical practice due to its technical complexity, semi-quantitative contrast-weighted nature, and impractically long scan times needed for the extraction of quantitative molecular biomarkers. Deep MRF constitutes a remedy for these challenges, providing a quantitative and rapid framework for extracting biologically and/or clinically meaningful molecular information. Here, we define a standardized protocol and a practical, complete guide for quantitative molecular MRI using deep MRF. We describe in-vitro sample preparation, animal and human scan considerations, and provide intuition behind acquisition protocol design and optimization of chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) quantitative imaging. We then extensively describe the building blocks for several AI models and demonstrate their performance for different applications, including cancer monitoring, brain myelin imaging, and pH quantification. Finally, explicit guidelines for further modification and expansion of the pipeline for imaging a variety of other pathologies (such as neurodegeneration, stroke, and cardiac disease) are given, accompanied by detailed open-source code and sample data. The protocol takes ~48 min - 57 hrs to complete by a scientist at the graduate student level.
- Open Access
- 4 May 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (10) , e4954
Global deep learning optimization of chemical exchange saturation transfer magnetic resonance fingerprinting acquisition schedule
Chemical exchange saturation transfer (CEST) MRI is a promising molecular imaging technique but suffers from long scan times and complicated processing. CEST was recently combined with magnetic resonance fingerprinting (MRF) to address these shortcomings. However, the CEST‐MRF signal depends on multiple acquisition and tissue parameters so selecting an optimal acquisition schedule is challenging. In this work, we propose a novel dual‐network deep learning framework to optimize the CEST‐MRF acquisition schedule. The quality of the optimized schedule was assessed in a digital brain phantom and compared with alternate deep learning optimization approaches. The effect of schedule length on the reconstruction error was also investigated. A healthy subject was scanned with optimized and random schedules and with a conventional CEST sequence for comparison. The optimized schedule was also tested in a subject with metastatic renal cell carcinoma. Reproducibility was assessed via test–retest experiments and the concordance correlation coefficient calculated for white matter (WM) and grey matter (GM). The optimized schedule was 12% shorter but yielded equal or lower normalized root mean square error for all parameters. The proposed optimization also provided a lower error compared with alternate methodologies. Longer schedules generally yielded lower error. In vivo maps obtained with the optimized schedule showed reduced noise and improved delineation of GM and WM. CEST curves synthesized from the optimized parameters were highly correlated (r = 0.99) with measured conventional CEST. The mean concordance correlation coefficient in WM/GM for all tissue parameters was 0.990/0.978 for the optimized schedule but only 0.979/0.975 for the random schedule. The proposed schedule optimization is widely applicable to MRF pulse sequences and provides accurate and reproducible tissue maps with reduced noise at a shorter scan time than a randomly generated schedule.
- 4 May 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (10) , e4954
Open AccessGlobal deep learning optimization of chemical exchange saturation transfer magnetic resonance fingerprinting acquisition schedule
Chemical exchange saturation transfer (CEST) MRI is a promising molecular imaging technique but suffers from long scan times and complicated processing. CEST was recently combined with magnetic resonance fingerprinting (MRF) to address these shortcomings. However, the CEST‐MRF signal depends on multiple acquisition and tissue parameters so selecting an optimal acquisition schedule is challenging. In this work, we propose a novel dual‐network deep learning framework to optimize the CEST‐MRF acquisition schedule. The quality of the optimized schedule was assessed in a digital brain phantom and compared with alternate deep learning optimization approaches. The effect of schedule length on the reconstruction error was also investigated. A healthy subject was scanned with optimized and random schedules and with a conventional CEST sequence for comparison. The optimized schedule was also tested in a subject with metastatic renal cell carcinoma. Reproducibility was assessed via test–retest experiments and the concordance correlation coefficient calculated for white matter (WM) and grey matter (GM). The optimized schedule was 12% shorter but yielded equal or lower normalized root mean square error for all parameters. The proposed optimization also provided a lower error compared with alternate methodologies. Longer schedules generally yielded lower error. In vivo maps obtained with the optimized schedule showed reduced noise and improved delineation of GM and WM. CEST curves synthesized from the optimized parameters were highly correlated (r = 0.99) with measured conventional CEST. The mean concordance correlation coefficient in WM/GM for all tissue parameters was 0.990/0.978 for the optimized schedule but only 0.979/0.975 for the random schedule. The proposed schedule optimization is widely applicable to MRF pulse sequences and provides accurate and reproducible tissue maps with reduced noise at a shorter scan time than a randomly generated schedule.
- Open Access
- 21 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (1) , 233-249
CEST MR fingerprinting (CEST‐MRF) for brain tumor quantification using EPI readout and deep learning reconstruction
Purpose: To develop a clinical CEST MR fingerprinting (CEST‐MRF) method for brain tumor quantification using EPI acquisition and deep learning reconstruction.Methods: A CEST‐MRF pulse sequence originally designed for animal imaging was modified to conform to hardware limits on clinical scanners while keeping scan time under 2 min. Quantitative MRF reconstruction was performed using a deep reconstruction network (DRONE) to yield the water relaxation and chemical exchange parameters. The feasibility of the six parameter DRONE reconstruction was tested in simulations using a digital brain phantom. A healthy subject was scanned with the CEST‐MRF sequence, conventional MRF and CEST sequences for comparison. Reproducibility was assessed via test–retest experiments and the concordance correlation coefficient calculated for white matter and gray matter. The clinical utility of CEST‐MRF was demonstrated on four patients with brain metastases in comparison to standard clinical imaging sequences. Tumors were segmented into edema, solid core, and necrotic core regions and the CEST‐MRF values compared to the contra‐lateral side.Results: DRONE reconstruction of the digital phantom yielded a normalized RMS error of ≤7% for all parameters. The CEST‐MRF parameters were in good agreement with those from conventional MRF and CEST sequences and previous studies. The mean concordance correlation coefficient for all six parameters was 0.98 ± 0.01 in white matter and 0.98 ± 0.02 in gray matter. The CEST‐MRF values in nearly all tumor regions were significantly different (P = 0.05) from each other and the contra‐lateral side.Conclusion: Combination of EPI readout and deep learning reconstruction enabled fast, accurate and reproducible CEST‐MRF in brain tumors.
- 21 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (1) , 233-249
Open AccessCEST MR fingerprinting (CEST‐MRF) for brain tumor quantification using EPI readout and deep learning reconstruction
Purpose: To develop a clinical CEST MR fingerprinting (CEST‐MRF) method for brain tumor quantification using EPI acquisition and deep learning reconstruction.Methods: A CEST‐MRF pulse sequence originally designed for animal imaging was modified to conform to hardware limits on clinical scanners while keeping scan time under 2 min. Quantitative MRF reconstruction was performed using a deep reconstruction network (DRONE) to yield the water relaxation and chemical exchange parameters. The feasibility of the six parameter DRONE reconstruction was tested in simulations using a digital brain phantom. A healthy subject was scanned with the CEST‐MRF sequence, conventional MRF and CEST sequences for comparison. Reproducibility was assessed via test–retest experiments and the concordance correlation coefficient calculated for white matter and gray matter. The clinical utility of CEST‐MRF was demonstrated on four patients with brain metastases in comparison to standard clinical imaging sequences. Tumors were segmented into edema, solid core, and necrotic core regions and the CEST‐MRF values compared to the contra‐lateral side.Results: DRONE reconstruction of the digital phantom yielded a normalized RMS error of ≤7% for all parameters. The CEST‐MRF parameters were in good agreement with those from conventional MRF and CEST sequences and previous studies. The mean concordance correlation coefficient for all six parameters was 0.98 ± 0.01 in white matter and 0.98 ± 0.02 in gray matter. The CEST‐MRF values in nearly all tumor regions were significantly different (P = 0.05) from each other and the contra‐lateral side.Conclusion: Combination of EPI readout and deep learning reconstruction enabled fast, accurate and reproducible CEST‐MRF in brain tumors.
- Open Access
AI boosted molecular MRI for apoptosis detection in oncolytic virotherapy
Oncolytic virotherapy is a promising treatment for high mortality cancers 1 . Non-invasive imaging of the underlying molecular processes is an essential tool for therapy optimization and assessment of viral spread, innate immunity, and therapeutic response 2, 3 . However, previous methods for imaging oncolytic viruses did not correlate with late viral activity 4 or had poor sensitivity and specificity 5 . Similarly, methods developed to image treatment response, such as apoptosis, proved to be slow, nonspecific, or require the use of radioactive or metal-based contrast agents 6–8 . To date, no method has been widely adopted for clinical use. We describe here a new method for fast magnetic resonance molecular imaging with quantitative proton chemical-exchange specificity to monitor oncolytic virotherapy treatment response. A deep neural network enabled the computation of quantitative biomarker maps of protein and lipid/macromolecule concentrations as well as intracellular pH in a glioblastoma multiforme mouse brain tumor model. Early detection of apoptotic response to oncolytic virotherapy, characterized by decreased cytosolic pH and protein synthesis, was observed in agreement with histology. Clinical translation was demonstrated in a normal human subject, yielding molecular parameters in good agreement with literature values 9 . The developed method is directly applicable to a wide range of pathologies, including stroke 10 , cancer 11–13 , and neurological disorders 14, 15 .
Open AccessAI boosted molecular MRI for apoptosis detection in oncolytic virotherapy
Oncolytic virotherapy is a promising treatment for high mortality cancers 1 . Non-invasive imaging of the underlying molecular processes is an essential tool for therapy optimization and assessment of viral spread, innate immunity, and therapeutic response 2, 3 . However, previous methods for imaging oncolytic viruses did not correlate with late viral activity 4 or had poor sensitivity and specificity 5 . Similarly, methods developed to image treatment response, such as apoptosis, proved to be slow, nonspecific, or require the use of radioactive or metal-based contrast agents 6–8 . To date, no method has been widely adopted for clinical use. We describe here a new method for fast magnetic resonance molecular imaging with quantitative proton chemical-exchange specificity to monitor oncolytic virotherapy treatment response. A deep neural network enabled the computation of quantitative biomarker maps of protein and lipid/macromolecule concentrations as well as intracellular pH in a glioblastoma multiforme mouse brain tumor model. Early detection of apoptotic response to oncolytic virotherapy, characterized by decreased cytosolic pH and protein synthesis, was observed in agreement with histology. Clinical translation was demonstrated in a normal human subject, yielding molecular parameters in good agreement with literature values 9 . The developed method is directly applicable to a wide range of pathologies, including stroke 10 , cancer 11–13 , and neurological disorders 14, 15 .
- 9 August 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (2) , 462-478
CEST MR‐Fingerprinting: Practical considerations and insights for acquisition schedule design and improved reconstruction
Purpose: To understand the influence of various acquisition parameters on the ability of CEST MR‐Fingerprinting (MRF) to discriminate different chemical exchange parameters and to provide tools for optimal acquisition schedule design and parameter map reconstruction.Methods: Numerical simulations were conducted using a parallel computing implementation of the Bloch‐McConnell equations, examining the effect of TR, TE, flip‐angle, water and , saturation‐pulse duration, power, and frequency on the discrimination ability of CEST‐MRF. A modified Euclidean distance matching metric was evaluated and compared to traditional dot product matching. L‐Arginine phantoms of various concentrations and pH were scanned at 4.7T and the results compared to numerical findings.Results: Simulations for dot product matching demonstrated that the optimal flip‐angle and saturation times are and 1100 ms, respectively. The optimal maximal saturation power was 3.4 μT for concentrated solutes with a slow exchange rate, and 5.2 μT for dilute solutes with medium‐to‐fast exchange rates. Using the Euclidean distance matching metric, much lower maximum saturation powers were required (1.6 and 2.4 μT, respectively), with a slightly longer saturation time (1500 ms) and flip‐angle. For both matching metrics, the discrimination ability increased with the repetition time. The experimental results were in agreement with simulations, demonstrating that more than a 50% reduction in scan‐time can be achieved by Euclidean distance‐based matching.Conclusions: Optimization of the CEST‐MRF acquisition schedule is critical for obtaining the best exchange parameter accuracy. The use of Euclidean distance‐based matching of signal trajectories simultaneously improved the discrimination ability and reduced the scan time and maximal saturation power required.
- 9 August 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (2) , 462-478
CEST MR‐Fingerprinting: Practical considerations and insights for acquisition schedule design and improved reconstruction
Purpose: To understand the influence of various acquisition parameters on the ability of CEST MR‐Fingerprinting (MRF) to discriminate different chemical exchange parameters and to provide tools for optimal acquisition schedule design and parameter map reconstruction.Methods: Numerical simulations were conducted using a parallel computing implementation of the Bloch‐McConnell equations, examining the effect of TR, TE, flip‐angle, water and , saturation‐pulse duration, power, and frequency on the discrimination ability of CEST‐MRF. A modified Euclidean distance matching metric was evaluated and compared to traditional dot product matching. L‐Arginine phantoms of various concentrations and pH were scanned at 4.7T and the results compared to numerical findings.Results: Simulations for dot product matching demonstrated that the optimal flip‐angle and saturation times are and 1100 ms, respectively. The optimal maximal saturation power was 3.4 μT for concentrated solutes with a slow exchange rate, and 5.2 μT for dilute solutes with medium‐to‐fast exchange rates. Using the Euclidean distance matching metric, much lower maximum saturation powers were required (1.6 and 2.4 μT, respectively), with a slightly longer saturation time (1500 ms) and flip‐angle. For both matching metrics, the discrimination ability increased with the repetition time. The experimental results were in agreement with simulations, demonstrating that more than a 50% reduction in scan‐time can be achieved by Euclidean distance‐based matching.Conclusions: Optimization of the CEST‐MRF acquisition schedule is critical for obtaining the best exchange parameter accuracy. The use of Euclidean distance‐based matching of signal trajectories simultaneously improved the discrimination ability and reduced the scan time and maximal saturation power required.
- 18 April 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 51, 1-6
Ex vivo mouse brain microscopy at 15T with loop-gap RF coil
- 18 April 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 51, 1-6
Ex vivo mouse brain microscopy at 15T with loop-gap RF coil