Variation in the outer diameter of vascular sheaths commonly used in infant cardiac catheterization
- 29 February 2020
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (3) , 620-625
Abstract
Objective: To compare the outer diameter (OD) of conventional and radial sheaths from different manufacturers for sizes typically used in infant catheterization.Background: The smallest sheath size is recommended to minimize risk of arterial injury in infants. However, sheath size refers to its internal diameter (ID), but it is the larger OD that determines risk. The OD varies between manufacturers and is frequently not known to the end user.Methods: Three authors measured the OD of 3, 3.3, 4, 5, and 6 French (Fr) sheaths from different manufacturers using a Mitutoyo digital micrometer. Continuous variables are reported as mean ± SD. The midshaft and proximal‐shaft sheath measurements were compared using an independent samples t test. Agreement between author measurements was tested using intra‐ and inter‐rater reliability analysis. Manufacturer sheath OD measurements were obtained. Statistical significance was set at p < .05.Results: There was no difference in the measured sheath diameters at the midpoint and proximally (p < .05). The intra‐rater and inter‐rater reliability were excellent (Intraclass correlation coefficient 1.0). Among conventional sheaths the OD varied between manufacturers, Terumo sheaths had the smallest and Galt sheaths had the largest OD. Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 ± 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 ± 0.016 mm) and 3.3 Fr (1.635 ± 0.005 mm) sheaths.Conclusions: Our study shows variation in the OD of sheaths used in infant catheterization. The radial sheaths offer the smallest OD across sizes.Keywords
Funding Information
- Childrens Mercy Hospital
This publication has 9 references indexed in Scilit:
- First prospective multicenter experience with the 7 French Glidesheath slender for complex transradial coronary interventionsCatheterization and Cardiovascular Interventions, 2016
- Ultrasound‐guided femoral arterial access in pediatric cardiac catheterizations: A prospective evaluation of the prevalence, risk factors, and mechanism for acute loss of arterial pulseCatheterization and Cardiovascular Interventions, 2016
- Safety and feasibility of the new 5 Fr Glidesheath SlenderCardiovascular Intervention and Therapeutics, 2015
- Focus on maximal miniaturisation of transradial coronary access materials and techniques by the Slender Club Japan and Europe: an overview and classificationEuroIntervention, 2015
- Incidence and predictors of cardiac catheterisation-related arterial thrombosis in childrenHeart, 2015
- Initial experience with the glidesheath slender for transradial coronary angiography and intervention: A feasibility study with prospective radial ultrasound follow‐upCatheterization and Cardiovascular Interventions, 2013
- Prevalence of and risk factors for acute occlusive arterial injury following pediatric cardiac catheterization: A large single‐center cohort studyCatheterization and Cardiovascular Interventions, 2013
- Use of 3 French catheters for diagnostic and interventional procedures in newborns and small infants: Table 1Heart, 2003
- Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary interventionCatheterization and Cardiovascular Interventions, 1999