Comparison of Radiosurgery Planning Modalities for Acoustic Neuroma with Regard to Conformity and Mean Target Dose
Authors:
- J.R. PerksJPJ.R. Perks
- K. El-HamriKEK. El-Hamri
- T.P.D. BlackburnTBT.P.D. Blackburn
- P.N. PlowmanPPP.N. Plowman
- 1 December 2005
- journal article
- research article
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 83 (4) , 165-171
Abstract
Purpose: To evaluate dose conformity and mean target dose in light of previous comparative studies and state-of-the-art radiosurgery delivery modalities. Materials and Methods: Seven patients with acoustic neuromas deemed clinically suitable for linear accelerator or Gamma Knife radiosurgery were planned such that the minimum doses for any plan were equal. Gamma Knife plans were prepared in three ways: by altering the prescription of previously published data, by hand and with the assistance of an automatic planning algorithm (wizard). The linear accelerator plans were prepared utilizing a micro-multileaf collimator in both static and dynamic modes. The dose volume histogram analyses lead to a measure of conformity and the mean and minimum target dose for each plan. Statistical significance was calculated as each planning modality was compared with every other. Results: All Gamma Knife plans demonstrated a statistically significantly better conformity when compared with fixed field linear accelerator techniques. When compared to linear accelerator techniques the wizard-assisted Gamma Knife plans demonstrated significantly better conformity. The mean target dose for all the Gamma Knife plans was significantly higher than that of the linear accelerator plans (19.2 Gy vs. 13.4 Gy). Conclusions: Conformity of the prescription isodose to the target shape is of major importance in radiosurgery. The modalities compared represent commercially available and widely accepted systems. Gamma Knife plans derived using the ‘wizard’ option and finalized by hand yield the best conformity.Keywords
This publication has 16 references indexed in Scilit:
- Stereotactic radiosurgery XVI: Isodosimetric comparison of photon stereotactic radiosurgery techniques (gamma knife vs. micromultileaf collimator linear accelerator) for acoustic neuroma—and potential clinical importanceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2003
- The CyberKnife Stereotactic Radiosurgery System: Description, Installation, and an Initial Evaluation of Use and FunctionalityNeurosurgery, 2003
- Post-radiation sensorineuronal hearing lossInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Isotropic beam bouquets for shaped beam linear accelerator radiosurgeryPhysics in Medicine & Biology, 2001
- Stereotactic radiosurgery and fractionated stereotactic radiotherapy for the treatment of acoustic schwannomas: comparative observations of 125 patients treated at one institutionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Intensity-modulated stereotactic radiosurgery using dynamic micro-multileaf collimationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Results of acoustic neuroma radiosurgery: an analysis of 5 years' experience using current methodsJournal of Neurosurgery, 2001
- Stereotactic Radiosurgery, X: Clinical Isodosimetry of Gamma Knife Versus Linear Accelerator X-Knife for Pituitary and Acoustic TumoursClinical Oncology, 1999
- Commissioning of a Micro-Multileaf Collimator for Conformal Stereotactic Radiosurgery and Radiotherapy1999
- Comparison of radiosurgery treatment modalities based on physical dose distributionsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998