JPJulian R. Perks

Julian R. Perks

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julian R. Perks has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Failure Mode and Effect Analysis for Delivery of Lung Stereotactic Body Radiation Therapy

    by Julian R. Perks, Sinisa Stanic, Robin L. Stern, Barbara Henk, Marsha S. Nelson, Rick D. Harse, Mathew Mathai, James A. Purdy, Richard K. Valicenti, Allan D. Siefkin, et al.


  • Comparison of peripheral dose from image-guided radiation therapy (IGRT) using kV cone beam CT to intensity-modulated radiation therapy (IMRT)

    by Julian R. Perks, Jöerg Lehmann, Allen M. Chen, Claus C. Yang, Robin L. Stern, James A. Purdy


  • Open Access

    Commissioning experience with cone‐beam computed tomography for image‐guided radiation therapy

    by Joerg Lehmann, Julian Perks, Sheldon Semon, Rick Harse, James A. Purdy

    This paper reports on the commissioning of an Elekta cone‐beam computed tomography (CT) system at one of the first U.S. sites to install a “regular,” off‐the‐shelf Elekta Synergy (Elekta, Stockholm, Sweden) accelerator system. We present the quality assurance (QA) procedure as a guide for other users. The commissioning had six elements: (1) system safety, (2) geometric accuracy (agreement of megavoltage and kilovoltage beam isocenters), (3) image quality, (4) registration and correction accuracy, (5) dose to patient and dosimetric stability, and (6) QA procedures. The system passed the safety tests, and agreement of the isocenters was found to be within 1 mm. Using a precisely moved skull phantom, the reconstruction and alignment algorithm was found to be accurate within 1 mm and 1 degree in each dimension. Of 12 measurement points spanning a ‐cm volume in a Rando phantom (The Phantom Laboratory, Salem, NY), the average agreement in the x, y, and z coordinates was 0.10 mm, mm, and 0.22 mm [standard deviations (SDs): 0.21 mm, 0.55 mm, 0.21 mm; largest deviations: 0.6 mm, 1.0 mm, 0.5 mm] respectively. The larger deviation for the y component can be partly attributed to the CT slice thickness of 1 mm in that direction. Dose to the patient depends on the machine settings and patient geometry. To monitor dose consistency, air kerma (output) and half‐value layer (beam quality) are measured for a typical clinical setting. Air kerma was 6.3 cGy (120 kVp, 40 mA, 40 ms per frame, 360‐degree scan, S20 field of view); half value layer was 7.1 mm aluminum (120 kV, 40 mA).We suggest performing items 1, 2, and 3 monthly, and 4 and 5 annually. In addition, we devised a daily QA procedure to verify agreement of the megavoltage and kilovoltage isocenters using a simple phantom containing three small steel balls. The frequency of all checks will be reevaluated based on data collected during about 1 year.PACS number: 87.53.Xd


  • Clinical impact of magnetic resonance imaging on Gamma Knife surgery for brain metastases

    by Julian R. Perks, Tianxiao Liu, William H. Hall, Allan Y. Chen

    Object: Stereotactic radiosurgery is beneficial for patients with a limited number of small brain metastases. Increased numbers of brain metastases, not infrequently at unreachable locations, are identified using thin-section magnetic resonance (MR) imaging on the day of Gamma Knife surgery (GKS). To improve patient selection and design better treatment strategies, a retrospective study was conducted to determine factors that may contribute to detecting additional brain metastases on the day of GKS.Methods: A total of 100 patients with brain metastases who underwent GKS between October 2003 and May 2006 at the University of California Davis Medical Center were included in the present study. Patients were categorized by age, sex, Karnofsky Performance Scale score, status of systemic disease, histological characteristics of the primary tumor, and whether they received previous whole-brain radiotherapy (WBRT). The number of lesions identified by diagnostic MR imaging at referral, by thin-section double-contrast MR imaging on the day of GKS, and the actual lesions treated by GKS were recorded. The diagnostic MR images were categorized in terms of section thickness and time interval before GKS.Conclusions: The characteristics of this patient population match well with the general GKS practice. Fifty-six had been treated with WBRT. On average, patients presented with 2.2 ± 1.7 lesions, a number based on their original diagnostic MR imaging, had 3.6 ± 3.4 lesions identified on the thin-section treatment MR imaging (p < 0.05), and underwent treatment of 3.1 ± 2.6 lesions on the day of GKS. Significantly, treatment was compromised in 21 patients, in whom not all additional lesions could be treated with the initial headframe placement. Analysis shows that a significantly greater number of lesions were detected using thin-section MR imaging on the day of GKS in patients who had undergone thick-section diagnostic MR imaging, did not receive WBRT, and had progressive systemic disease. To optimize treatment planning and minimize additional treatment, the number of metastases needs to be determined accurately before frame placement, ideally by performing thin-section MR imaging, as used on the day of GKS.


  • Comparison of Radiosurgery Planning Modalities for Acoustic Neuroma with Regard to Conformity and Mean Target Dose

    by J.R. Perks, K. El-Hamri, T.P.D. Blackburn, P.N. Plowman

    Purpose: To evaluate dose conformity and mean target dose in light of previous comparative studies and state-of-the-art radiosurgery delivery modalities. Materials and Methods: Seven patients with acoustic neuromas deemed clinically suitable for linear accelerator or Gamma Knife radiosurgery were planned such that the minimum doses for any plan were equal. Gamma Knife plans were prepared in three ways: by altering the prescription of previously published data, by hand and with the assistance of an automatic planning algorithm (wizard). The linear accelerator plans were prepared utilizing a micro-multileaf collimator in both static and dynamic modes. The dose volume histogram analyses lead to a measure of conformity and the mean and minimum target dose for each plan. Statistical significance was calculated as each planning modality was compared with every other. Results: All Gamma Knife plans demonstrated a statistically significantly better conformity when compared with fixed field linear accelerator techniques. When compared to linear accelerator techniques the wizard-assisted Gamma Knife plans demonstrated significantly better conformity. The mean target dose for all the Gamma Knife plans was significantly higher than that of the linear accelerator plans (19.2 Gy vs. 13.4 Gy). Conclusions: Conformity of the prescription isodose to the target shape is of major importance in radiosurgery. The modalities compared represent commercially available and widely accepted systems. Gamma Knife plans derived using the ‘wizard’ option and finalized by hand yield the best conformity.


  • Glass rod detectors for small field, stereotactic radiosurgery dosimetric audit

    by J. Perks, M. Gao, V. Smith, S. Skubic, S Goetsch

    This paper demonstrates the feasibility of using glass rod detectors for quality assurance audit of radiosurgery units. Five radiosurgery units (3 Gamma Knife model C, 1 Gamma Knife model U and 1 Cyberknife) located in California participated in the study. At each center glass rod detectors were used to measure a number of dosimetric parameters including relative collimator output factor and absolute dose rate. The Gamma Knife data obtained is in excellent agreement with the commissioning data generated by the manufacturer for each unit and the Cyberknife data is in general agreement with the data published by other centers. In particular the output factor of the 4 mm Gamma Knife helmet factor, a subject of abundant debate, was measured in the range 0.863–0.872 with an accuracy of better than 1% across the four participating centers. It is hoped that this pilot study will facilitate a nationwide postal audit of stereotactic radiosurgery units.